Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey

Background: Population-based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25-hydroxyvitamin D [25(OH)D] concentrations. Methods: Concentrations of 25(OH)D3 and 25(OH)D2 were measu...

Full description

Bibliographic Details
Published in:Journal of Clinical Laboratory Analysis
Main Authors: Berry, Diane J., Dutton, John, Fraser, William D., Järvelin, Marjo-Riitta, Hyppönen, Elina
Format: Article in Journal/Newspaper
Language:English
Published: 2017
Subjects:
Online Access:https://ueaeprints.uea.ac.uk/id/eprint/60224/
https://ueaeprints.uea.ac.uk/id/eprint/60224/1/Published_manuscript.pdf
https://doi.org/10.1002/jcla.22049
id ftuniveastangl:oai:ueaeprints.uea.ac.uk:60224
record_format openpolar
spelling ftuniveastangl:oai:ueaeprints.uea.ac.uk:60224 2023-05-15T17:42:39+02:00 Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey Berry, Diane J. Dutton, John Fraser, William D. Järvelin, Marjo-Riitta Hyppönen, Elina 2017-05 application/pdf https://ueaeprints.uea.ac.uk/id/eprint/60224/ https://ueaeprints.uea.ac.uk/id/eprint/60224/1/Published_manuscript.pdf https://doi.org/10.1002/jcla.22049 en eng https://ueaeprints.uea.ac.uk/id/eprint/60224/1/Published_manuscript.pdf Berry, Diane J., Dutton, John, Fraser, William D., Järvelin, Marjo-Riitta and Hyppönen, Elina (2017) Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey. Journal of Clinical Laboratory Analysis, 31 (3). ISSN 0887-8013 doi:10.1002/jcla.22049 Article PeerReviewed 2017 ftuniveastangl https://doi.org/10.1002/jcla.22049 2023-01-30T21:44:36Z Background: Population-based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25-hydroxyvitamin D [25(OH)D] concentrations. Methods: Concentrations of 25(OH)D3 and 25(OH)D2 were measured using LC-MS/MS in 5,915 participants (aged 31 years) of Northern Finland Birth Cohort 1966. Blood samples were assayed in batches over a course of 18 months. As anomalies were present in the measurements, 200 samples were reassayed using Diasorin RIA. Agreement between measurements was assessed by Passing–Bablok regression and limits of agreement (LoA). To harmonize LC-MS/MS with Diasorin RIA measurements, formulae were derived from the LoA. Results: Concentrations measured by LC-MS/MS were much higher than those measured by Diasorin RIA, with a mean difference of 12.9 ng/ml. Constant variation was evident between batch measurements after log transformation. Statistical formula was applied separately for each batch of LC-MS/MS measurements, enabling us to remove both the constant and proportional bias that was evident prior to the transformation. Conclusion: Despite the introduction of schemes/programs to improve accuracy of assays to measure 25(OH)D, significant differences can still happen. In these instances, methods to harmonize measurements based on a relatively small number of replicates can be successfully applied to establish confidence and to enable between-study comparisons. Article in Journal/Newspaper Northern Finland University of East Anglia: UEA Digital Repository Journal of Clinical Laboratory Analysis 31 3 e22049
institution Open Polar
collection University of East Anglia: UEA Digital Repository
op_collection_id ftuniveastangl
language English
description Background: Population-based research on vitamin D has increased dramatically in recent years. Such studies are typically reliant on assay procedures to measure reliable and comparable levels of 25-hydroxyvitamin D [25(OH)D] concentrations. Methods: Concentrations of 25(OH)D3 and 25(OH)D2 were measured using LC-MS/MS in 5,915 participants (aged 31 years) of Northern Finland Birth Cohort 1966. Blood samples were assayed in batches over a course of 18 months. As anomalies were present in the measurements, 200 samples were reassayed using Diasorin RIA. Agreement between measurements was assessed by Passing–Bablok regression and limits of agreement (LoA). To harmonize LC-MS/MS with Diasorin RIA measurements, formulae were derived from the LoA. Results: Concentrations measured by LC-MS/MS were much higher than those measured by Diasorin RIA, with a mean difference of 12.9 ng/ml. Constant variation was evident between batch measurements after log transformation. Statistical formula was applied separately for each batch of LC-MS/MS measurements, enabling us to remove both the constant and proportional bias that was evident prior to the transformation. Conclusion: Despite the introduction of schemes/programs to improve accuracy of assays to measure 25(OH)D, significant differences can still happen. In these instances, methods to harmonize measurements based on a relatively small number of replicates can be successfully applied to establish confidence and to enable between-study comparisons.
format Article in Journal/Newspaper
author Berry, Diane J.
Dutton, John
Fraser, William D.
Järvelin, Marjo-Riitta
Hyppönen, Elina
spellingShingle Berry, Diane J.
Dutton, John
Fraser, William D.
Järvelin, Marjo-Riitta
Hyppönen, Elina
Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey
author_facet Berry, Diane J.
Dutton, John
Fraser, William D.
Järvelin, Marjo-Riitta
Hyppönen, Elina
author_sort Berry, Diane J.
title Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey
title_short Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey
title_full Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey
title_fullStr Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey
title_full_unstemmed Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey
title_sort harmonization study between lc-ms/ms and diasorin ria for measurement of 25-hydroxyvitamin d concentrations in a large population survey
publishDate 2017
url https://ueaeprints.uea.ac.uk/id/eprint/60224/
https://ueaeprints.uea.ac.uk/id/eprint/60224/1/Published_manuscript.pdf
https://doi.org/10.1002/jcla.22049
genre Northern Finland
genre_facet Northern Finland
op_relation https://ueaeprints.uea.ac.uk/id/eprint/60224/1/Published_manuscript.pdf
Berry, Diane J., Dutton, John, Fraser, William D., Järvelin, Marjo-Riitta and Hyppönen, Elina (2017) Harmonization study between LC-MS/MS and Diasorin RIA for measurement of 25-hydroxyvitamin D concentrations in a large population survey. Journal of Clinical Laboratory Analysis, 31 (3). ISSN 0887-8013
doi:10.1002/jcla.22049
op_doi https://doi.org/10.1002/jcla.22049
container_title Journal of Clinical Laboratory Analysis
container_volume 31
container_issue 3
container_start_page e22049
_version_ 1766144544799195136