Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer

Dissolved nitrous oxide (N2O) concentrations are usually determined by gas chromatography (GC). Here we present laboratory tests and initial field measurements using a novel setup comprising a commercially available laser-based analyser for N2O, carbon monoxide and water vapour coupled to a glass-be...

Full description

Bibliographic Details
Published in:Ocean Science
Main Authors: Grefe, I., Kaiser, J.
Format: Article in Journal/Newspaper
Language:unknown
Published: 2014
Subjects:
Online Access:https://ueaeprints.uea.ac.uk/id/eprint/49021/
https://doi.org/10.5194/os-10-501-2014
id ftuniveastangl:oai:ueaeprints.uea.ac.uk:49021
record_format openpolar
spelling ftuniveastangl:oai:ueaeprints.uea.ac.uk:49021 2023-05-15T18:25:59+02:00 Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer Grefe, I. Kaiser, J. 2014-06-19 https://ueaeprints.uea.ac.uk/id/eprint/49021/ https://doi.org/10.5194/os-10-501-2014 unknown Grefe, I. and Kaiser, J. (2014) Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer. Ocean Science, 10 (3). pp. 501-512. ISSN 1812-0784 doi:10.5194/os-10-501-2014 Article PeerReviewed 2014 ftuniveastangl https://doi.org/10.5194/os-10-501-2014 2023-03-23T23:32:05Z Dissolved nitrous oxide (N2O) concentrations are usually determined by gas chromatography (GC). Here we present laboratory tests and initial field measurements using a novel setup comprising a commercially available laser-based analyser for N2O, carbon monoxide and water vapour coupled to a glass-bed equilibrator. This approach is less labour-intensive and provides higher temporal and spatial resolution than the conventional GC technique. The standard deviation of continuous equilibrator or atmospheric air measurements was 0.2 nmol mol−1 (averaged over 5 min). The short-term repeatability for reference gas measurements within 1 h of each other was 0.2 nmol mol−1 or better. Another indicator of the long-term stability of the analyser is the standard deviation of the calibrated N2O mole fraction in marine air, which was between 0.5 and 0.7 nmol mol−1. The equilibrator measurements were compared with purge-and-trap gas chromatography–mass spectrometry (GC-MS) analyses of N2O concentrations in discrete samples from the Southern Ocean and showed agreement to within the 2% measurement uncertainty of the GC-MS method. The equilibrator response time to concentration changes in water was from 142 to 203 s, depending on the headspace flow rate. The system was tested at sea during a north-to-south transect of the Atlantic Ocean. While the subtropical gyres were slightly undersaturated, the equatorial region was a source of nitrous oxide to the atmosphere, confirming previous findings (Forster et al., 2009). The ability to measure at high temporal and spatial resolution revealed submesoscale variability in dissolved N2O concentrations. Mean sea-to-air fluxes in the tropical and subtropical Atlantic ranged between −1.6 and 0.11 μmol m−2 d−1 and confirm that the subtropical Atlantic is not an important source region for N2O to the atmosphere, compared to global average fluxes of 0.6–2.4 μmol m−2 d−1. The system can be easily modified for autonomous operation on voluntary observing ships (VOS). Future work should include an ... Article in Journal/Newspaper Southern Ocean University of East Anglia: UEA Digital Repository Southern Ocean Ocean Science 10 3 501 512
institution Open Polar
collection University of East Anglia: UEA Digital Repository
op_collection_id ftuniveastangl
language unknown
description Dissolved nitrous oxide (N2O) concentrations are usually determined by gas chromatography (GC). Here we present laboratory tests and initial field measurements using a novel setup comprising a commercially available laser-based analyser for N2O, carbon monoxide and water vapour coupled to a glass-bed equilibrator. This approach is less labour-intensive and provides higher temporal and spatial resolution than the conventional GC technique. The standard deviation of continuous equilibrator or atmospheric air measurements was 0.2 nmol mol−1 (averaged over 5 min). The short-term repeatability for reference gas measurements within 1 h of each other was 0.2 nmol mol−1 or better. Another indicator of the long-term stability of the analyser is the standard deviation of the calibrated N2O mole fraction in marine air, which was between 0.5 and 0.7 nmol mol−1. The equilibrator measurements were compared with purge-and-trap gas chromatography–mass spectrometry (GC-MS) analyses of N2O concentrations in discrete samples from the Southern Ocean and showed agreement to within the 2% measurement uncertainty of the GC-MS method. The equilibrator response time to concentration changes in water was from 142 to 203 s, depending on the headspace flow rate. The system was tested at sea during a north-to-south transect of the Atlantic Ocean. While the subtropical gyres were slightly undersaturated, the equatorial region was a source of nitrous oxide to the atmosphere, confirming previous findings (Forster et al., 2009). The ability to measure at high temporal and spatial resolution revealed submesoscale variability in dissolved N2O concentrations. Mean sea-to-air fluxes in the tropical and subtropical Atlantic ranged between −1.6 and 0.11 μmol m−2 d−1 and confirm that the subtropical Atlantic is not an important source region for N2O to the atmosphere, compared to global average fluxes of 0.6–2.4 μmol m−2 d−1. The system can be easily modified for autonomous operation on voluntary observing ships (VOS). Future work should include an ...
format Article in Journal/Newspaper
author Grefe, I.
Kaiser, J.
spellingShingle Grefe, I.
Kaiser, J.
Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer
author_facet Grefe, I.
Kaiser, J.
author_sort Grefe, I.
title Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer
title_short Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer
title_full Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer
title_fullStr Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer
title_full_unstemmed Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer
title_sort equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer
publishDate 2014
url https://ueaeprints.uea.ac.uk/id/eprint/49021/
https://doi.org/10.5194/os-10-501-2014
geographic Southern Ocean
geographic_facet Southern Ocean
genre Southern Ocean
genre_facet Southern Ocean
op_relation Grefe, I. and Kaiser, J. (2014) Equilibrator-based measurements of dissolved nitrous oxide in the surface ocean using an integrated cavity output laser absorption spectrometer. Ocean Science, 10 (3). pp. 501-512. ISSN 1812-0784
doi:10.5194/os-10-501-2014
op_doi https://doi.org/10.5194/os-10-501-2014
container_title Ocean Science
container_volume 10
container_issue 3
container_start_page 501
op_container_end_page 512
_version_ 1766207753282387968