id ftunivcardiff:oai:https://orca.cardiff.ac.uk:34308
record_format openpolar
spelling ftunivcardiff:oai:https://orca.cardiff.ac.uk:34308 2023-05-15T18:22:11+02:00 The Keck Array: a pulse tube cooled CMB polarimeter Sheehy, C. D. Ade, Peter A. R. Aikin, R. W. Amiri, M. Benton, S. Bischoff, C. Bock, J. J. Bonetti, J. A. Brevik, J. A. Burger, B. Dowell, C. D. Duband, L. Filippini, J. P. Golwala, S. R. Halpern, M. Hasselfield, M. Hilton, G. Hristov, V. V. Irwin, K. Kaufman, J. P. Keating, B. G. Kovac, J. M. Kuo, C. L. Lange, A. E. Leitch, E. M. Lueker, M. Netterfield, C. B. Nguyen, H. T. Ogburn IV, R. W. Orlando, A. Pryke, C. L. Reintsema, C. Richter, S. Ruhl, J. E. Runyan, M. C. Staniszewski, Z. Stokes, S. Sudiwala, Rashmikant V. Teply, G. Thompson, K. L. Tolan, J. E. Turner, A. D. Wilson, P. Wong, C. L. Holland, Wayne S. Zmuidzinas, Jonas 2010 https://orca.cardiff.ac.uk/id/eprint/34308/ https://doi.org/10.1117/12.857871 unknown SPIE Sheehy, C. D., Ade, Peter A. R. https://orca.cardiff.ac.uk/view/cardiffauthors/A0479492.html orcid:0000-0002-5127-0401 orcid:0000-0002-5127-0401, Aikin, R. W., Amiri, M., Benton, S., Bischoff, C., Bock, J. J., Bonetti, J. A., Brevik, J. A., Burger, B., Dowell, C. D., Duband, L., Filippini, J. P., Golwala, S. R., Halpern, M., Hasselfield, M., Hilton, G., Hristov, V. V., Irwin, K., Kaufman, J. P., Keating, B. G., Kovac, J. M., Kuo, C. L., Lange, A. E., Leitch, E. M., Lueker, M., Netterfield, C. B., Nguyen, H. T., Ogburn IV, R. W., Orlando, A., Pryke, C. L., Reintsema, C., Richter, S., Ruhl, J. E., Runyan, M. C., Staniszewski, Z., Stokes, S., Sudiwala, Rashmikant V. https://orca.cardiff.ac.uk/view/cardiffauthors/A017000J.html orcid:0000-0003-3240-5304 orcid:0000-0003-3240-5304, Teply, G., Thompson, K. L., Tolan, J. E., Turner, A. D., Wilson, P. and Wong, C. L. 2010. The Keck Array: a pulse tube cooled CMB polarimeter. Presented at: Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V, San Diego, CA., 29 June 2010. Published in: Holland, Wayne S. and Zmuidzinas, Jonas eds. Proc. SPIE. SPIE, 77411R. 10.1117/12.857871 https://doi.org/10.1117/12.857871 doi:10.1117/12.857871 QC Physics Conference or Workshop Item PeerReviewed 2010 ftunivcardiff https://doi.org/10.1117/12.857871 2022-10-27T22:31:47Z The Keck Array is a cosmic microwave background (CMB) polarimeter that will begin observing from the South Pole in late 2010. The initial deployment will consist of three telescopes similar to BICEP2 housed in ultracompact, pulse tube cooled cryostats. Two more receivers will be added the following year. In these proceedings we report on the design and performance of the Keck cryostat. We also report some initial results on the performance of antenna-coupled TES detectors operating in the presence of a pulse tube. We find that the performance of the detectors is not seriously impacted by the replacement of BICEP2's liquid helium cryostat with a pulse tube cooled cryostat. Conference Object South pole Cardiff University: ORCA (Online Research @ Cardiff) South Pole SPIE Proceedings, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V 7741 77411R
institution Open Polar
collection Cardiff University: ORCA (Online Research @ Cardiff)
op_collection_id ftunivcardiff
language unknown
topic QC Physics
spellingShingle QC Physics
Sheehy, C. D.
Ade, Peter A. R.
Aikin, R. W.
Amiri, M.
Benton, S.
Bischoff, C.
Bock, J. J.
Bonetti, J. A.
Brevik, J. A.
Burger, B.
Dowell, C. D.
Duband, L.
Filippini, J. P.
Golwala, S. R.
Halpern, M.
Hasselfield, M.
Hilton, G.
Hristov, V. V.
Irwin, K.
Kaufman, J. P.
Keating, B. G.
Kovac, J. M.
Kuo, C. L.
Lange, A. E.
Leitch, E. M.
Lueker, M.
Netterfield, C. B.
Nguyen, H. T.
Ogburn IV, R. W.
Orlando, A.
Pryke, C. L.
Reintsema, C.
Richter, S.
Ruhl, J. E.
Runyan, M. C.
Staniszewski, Z.
Stokes, S.
Sudiwala, Rashmikant V.
Teply, G.
Thompson, K. L.
Tolan, J. E.
Turner, A. D.
Wilson, P.
Wong, C. L.
The Keck Array: a pulse tube cooled CMB polarimeter
topic_facet QC Physics
description The Keck Array is a cosmic microwave background (CMB) polarimeter that will begin observing from the South Pole in late 2010. The initial deployment will consist of three telescopes similar to BICEP2 housed in ultracompact, pulse tube cooled cryostats. Two more receivers will be added the following year. In these proceedings we report on the design and performance of the Keck cryostat. We also report some initial results on the performance of antenna-coupled TES detectors operating in the presence of a pulse tube. We find that the performance of the detectors is not seriously impacted by the replacement of BICEP2's liquid helium cryostat with a pulse tube cooled cryostat.
author2 Holland, Wayne S.
Zmuidzinas, Jonas
format Conference Object
author Sheehy, C. D.
Ade, Peter A. R.
Aikin, R. W.
Amiri, M.
Benton, S.
Bischoff, C.
Bock, J. J.
Bonetti, J. A.
Brevik, J. A.
Burger, B.
Dowell, C. D.
Duband, L.
Filippini, J. P.
Golwala, S. R.
Halpern, M.
Hasselfield, M.
Hilton, G.
Hristov, V. V.
Irwin, K.
Kaufman, J. P.
Keating, B. G.
Kovac, J. M.
Kuo, C. L.
Lange, A. E.
Leitch, E. M.
Lueker, M.
Netterfield, C. B.
Nguyen, H. T.
Ogburn IV, R. W.
Orlando, A.
Pryke, C. L.
Reintsema, C.
Richter, S.
Ruhl, J. E.
Runyan, M. C.
Staniszewski, Z.
Stokes, S.
Sudiwala, Rashmikant V.
Teply, G.
Thompson, K. L.
Tolan, J. E.
Turner, A. D.
Wilson, P.
Wong, C. L.
author_facet Sheehy, C. D.
Ade, Peter A. R.
Aikin, R. W.
Amiri, M.
Benton, S.
Bischoff, C.
Bock, J. J.
Bonetti, J. A.
Brevik, J. A.
Burger, B.
Dowell, C. D.
Duband, L.
Filippini, J. P.
Golwala, S. R.
Halpern, M.
Hasselfield, M.
Hilton, G.
Hristov, V. V.
Irwin, K.
Kaufman, J. P.
Keating, B. G.
Kovac, J. M.
Kuo, C. L.
Lange, A. E.
Leitch, E. M.
Lueker, M.
Netterfield, C. B.
Nguyen, H. T.
Ogburn IV, R. W.
Orlando, A.
Pryke, C. L.
Reintsema, C.
Richter, S.
Ruhl, J. E.
Runyan, M. C.
Staniszewski, Z.
Stokes, S.
Sudiwala, Rashmikant V.
Teply, G.
Thompson, K. L.
Tolan, J. E.
Turner, A. D.
Wilson, P.
Wong, C. L.
author_sort Sheehy, C. D.
title The Keck Array: a pulse tube cooled CMB polarimeter
title_short The Keck Array: a pulse tube cooled CMB polarimeter
title_full The Keck Array: a pulse tube cooled CMB polarimeter
title_fullStr The Keck Array: a pulse tube cooled CMB polarimeter
title_full_unstemmed The Keck Array: a pulse tube cooled CMB polarimeter
title_sort keck array: a pulse tube cooled cmb polarimeter
publisher SPIE
publishDate 2010
url https://orca.cardiff.ac.uk/id/eprint/34308/
https://doi.org/10.1117/12.857871
geographic South Pole
geographic_facet South Pole
genre South pole
genre_facet South pole
op_relation Sheehy, C. D., Ade, Peter A. R. https://orca.cardiff.ac.uk/view/cardiffauthors/A0479492.html orcid:0000-0002-5127-0401 orcid:0000-0002-5127-0401, Aikin, R. W., Amiri, M., Benton, S., Bischoff, C., Bock, J. J., Bonetti, J. A., Brevik, J. A., Burger, B., Dowell, C. D., Duband, L., Filippini, J. P., Golwala, S. R., Halpern, M., Hasselfield, M., Hilton, G., Hristov, V. V., Irwin, K., Kaufman, J. P., Keating, B. G., Kovac, J. M., Kuo, C. L., Lange, A. E., Leitch, E. M., Lueker, M., Netterfield, C. B., Nguyen, H. T., Ogburn IV, R. W., Orlando, A., Pryke, C. L., Reintsema, C., Richter, S., Ruhl, J. E., Runyan, M. C., Staniszewski, Z., Stokes, S., Sudiwala, Rashmikant V. https://orca.cardiff.ac.uk/view/cardiffauthors/A017000J.html orcid:0000-0003-3240-5304 orcid:0000-0003-3240-5304, Teply, G., Thompson, K. L., Tolan, J. E., Turner, A. D., Wilson, P. and Wong, C. L. 2010. The Keck Array: a pulse tube cooled CMB polarimeter. Presented at: Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V, San Diego, CA., 29 June 2010. Published in: Holland, Wayne S. and Zmuidzinas, Jonas eds. Proc. SPIE. SPIE, 77411R. 10.1117/12.857871 https://doi.org/10.1117/12.857871
doi:10.1117/12.857871
op_doi https://doi.org/10.1117/12.857871
container_title SPIE Proceedings, Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy V
container_volume 7741
container_start_page 77411R
_version_ 1766201554258362368