Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil)
The Emergency Antarctic Modules ”“ MAE have been serving to the continuity of the activities undertaken at the Keller Peninsula since 2013, after the fire that destroyed part of the Brazilian Comandante Ferraz Antarctic Station. Taking into account the climatic conditions, the thermal comfort needs,...
Published in: | Paranoá: cadernos de arquitetura e urbanismo |
---|---|
Main Authors: | , |
Format: | Article in Journal/Newspaper |
Language: | Portuguese |
Published: |
Programa de Pós-graduação em Arquitetura e Urbanismo, Faculdade de Arquitetura e Urbanismo
2018
|
Subjects: | |
Online Access: | https://periodicos.unb.br/index.php/paranoa/article/view/24047 https://doi.org/10.18830/issn.1679-0944.n20.2018.06 |
id |
ftunivbrasilojs:oai:ojs.pkp.sfu.ca:article/24047 |
---|---|
record_format |
openpolar |
spelling |
ftunivbrasilojs:oai:ojs.pkp.sfu.ca:article/24047 2023-10-01T03:52:09+02:00 Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil) Martins, Wagner Gomes Alvarez, Cristina Engel de 2018-07-30 application/pdf https://periodicos.unb.br/index.php/paranoa/article/view/24047 https://doi.org/10.18830/issn.1679-0944.n20.2018.06 por por Programa de Pós-graduação em Arquitetura e Urbanismo, Faculdade de Arquitetura e Urbanismo https://periodicos.unb.br/index.php/paranoa/article/view/24047/21571 https://periodicos.unb.br/index.php/paranoa/article/view/24047 doi:10.18830/issn.1679-0944.n20.2018.06 Paranoá; No. 20 (2018): Paranoá 20 - Janeiro/Junho - Fluxo Contínuo Paranoá; n. 20 (2018): Paranoá 20 - Janeiro/Junho - Fluxo Contínuo 1679-0944 1677-7395 Módulos Antárticos Emergenciais Antártica Desempenho Térmico Avaliação Pós-Ocupação Emergency Antarctic Modules Antarctica Thermal Performance Post-Occupancy Evaluation info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion 2018 ftunivbrasilojs https://doi.org/10.18830/issn.1679-0944.n20.2018.06 2023-09-03T07:03:44Z The Emergency Antarctic Modules ”“ MAE have been serving to the continuity of the activities undertaken at the Keller Peninsula since 2013, after the fire that destroyed part of the Brazilian Comandante Ferraz Antarctic Station. Taking into account the climatic conditions, the thermal comfort needs, the energy consumption and the impact on the environment, the performance of the built complex was assessed particularly in terms of maintaining a stable internal temperature within an acceptance range according to the standards, also considering the insulation provided by the envelopment. Through measurements of temperature, the processing of the collected data and the analysis of the results, it was found that there was no correlation between the internal and the external temperatures, so that it is possible to infer that the envelope ensures the required insulation, despite some identified problems concerning the air tightness of the building, and/or that the heating system is able to compensate the differences of temperature. It is possible that the observed temperature drifts have been caused by the behavior in use, with heat loss by opening doors, for example, especially in the summer period, when there is a greater amount of users in the MAE. Os Módulos Antárticos Emergenciais ”“ MAE, instalados na Península Keller, desde 2013 têm servido à continuidade das atividades desenvolvidas no local após o incêndio de parte da brasileira Estação Antártica Comandante Ferraz. Tendo-se em vista as condições climáticas extremas e a necessidade de se obter conforto térmico com o menor gasto energético e impacto ao meio-ambiente, avaliou-se o desempenho do conjunto edificado, particularmente quanto à sua capacidade de manter a temperatura interna estável e dentro de uma faixa de aceitação conforme as normas aplicáveis, considerando-se também o isolamento proporcionado pela envoltória. Através de medições de temperatura, com o tratamento dos dados coletados e a análise dos resultados, verificou-se que não houve correlação ... Article in Journal/Newspaper Antarc* Antarctic Antarctica Antártica Universidade de Brasília: Portal de Periódicos da UnB Antarctic Keller ENVELOPE(-58.406,-58.406,-62.073,-62.073) Ferraz ENVELOPE(-64.117,-64.117,-65.117,-65.117) península Keller ENVELOPE(-61.333,-61.333,-74.250,-74.250) Keller peninsula ENVELOPE(-58.406,-58.406,-62.073,-62.073) Paranoá: cadernos de arquitetura e urbanismo 20 |
institution |
Open Polar |
collection |
Universidade de Brasília: Portal de Periódicos da UnB |
op_collection_id |
ftunivbrasilojs |
language |
Portuguese |
topic |
Módulos Antárticos Emergenciais Antártica Desempenho Térmico Avaliação Pós-Ocupação Emergency Antarctic Modules Antarctica Thermal Performance Post-Occupancy Evaluation |
spellingShingle |
Módulos Antárticos Emergenciais Antártica Desempenho Térmico Avaliação Pós-Ocupação Emergency Antarctic Modules Antarctica Thermal Performance Post-Occupancy Evaluation Martins, Wagner Gomes Alvarez, Cristina Engel de Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil) |
topic_facet |
Módulos Antárticos Emergenciais Antártica Desempenho Térmico Avaliação Pós-Ocupação Emergency Antarctic Modules Antarctica Thermal Performance Post-Occupancy Evaluation |
description |
The Emergency Antarctic Modules ”“ MAE have been serving to the continuity of the activities undertaken at the Keller Peninsula since 2013, after the fire that destroyed part of the Brazilian Comandante Ferraz Antarctic Station. Taking into account the climatic conditions, the thermal comfort needs, the energy consumption and the impact on the environment, the performance of the built complex was assessed particularly in terms of maintaining a stable internal temperature within an acceptance range according to the standards, also considering the insulation provided by the envelopment. Through measurements of temperature, the processing of the collected data and the analysis of the results, it was found that there was no correlation between the internal and the external temperatures, so that it is possible to infer that the envelope ensures the required insulation, despite some identified problems concerning the air tightness of the building, and/or that the heating system is able to compensate the differences of temperature. It is possible that the observed temperature drifts have been caused by the behavior in use, with heat loss by opening doors, for example, especially in the summer period, when there is a greater amount of users in the MAE. Os Módulos Antárticos Emergenciais ”“ MAE, instalados na Península Keller, desde 2013 têm servido à continuidade das atividades desenvolvidas no local após o incêndio de parte da brasileira Estação Antártica Comandante Ferraz. Tendo-se em vista as condições climáticas extremas e a necessidade de se obter conforto térmico com o menor gasto energético e impacto ao meio-ambiente, avaliou-se o desempenho do conjunto edificado, particularmente quanto à sua capacidade de manter a temperatura interna estável e dentro de uma faixa de aceitação conforme as normas aplicáveis, considerando-se também o isolamento proporcionado pela envoltória. Através de medições de temperatura, com o tratamento dos dados coletados e a análise dos resultados, verificou-se que não houve correlação ... |
format |
Article in Journal/Newspaper |
author |
Martins, Wagner Gomes Alvarez, Cristina Engel de |
author_facet |
Martins, Wagner Gomes Alvarez, Cristina Engel de |
author_sort |
Martins, Wagner Gomes |
title |
Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil) |
title_short |
Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil) |
title_full |
Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil) |
title_fullStr |
Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil) |
title_full_unstemmed |
Avaliação de desempenho térmico nos Módulos Antárticos Emergenciais (Brasil) |
title_sort |
avaliação de desempenho térmico nos módulos antárticos emergenciais (brasil) |
publisher |
Programa de Pós-graduação em Arquitetura e Urbanismo, Faculdade de Arquitetura e Urbanismo |
publishDate |
2018 |
url |
https://periodicos.unb.br/index.php/paranoa/article/view/24047 https://doi.org/10.18830/issn.1679-0944.n20.2018.06 |
long_lat |
ENVELOPE(-58.406,-58.406,-62.073,-62.073) ENVELOPE(-64.117,-64.117,-65.117,-65.117) ENVELOPE(-61.333,-61.333,-74.250,-74.250) ENVELOPE(-58.406,-58.406,-62.073,-62.073) |
geographic |
Antarctic Keller Ferraz península Keller Keller peninsula |
geographic_facet |
Antarctic Keller Ferraz península Keller Keller peninsula |
genre |
Antarc* Antarctic Antarctica Antártica |
genre_facet |
Antarc* Antarctic Antarctica Antártica |
op_source |
Paranoá; No. 20 (2018): Paranoá 20 - Janeiro/Junho - Fluxo Contínuo Paranoá; n. 20 (2018): Paranoá 20 - Janeiro/Junho - Fluxo Contínuo 1679-0944 1677-7395 |
op_relation |
https://periodicos.unb.br/index.php/paranoa/article/view/24047/21571 https://periodicos.unb.br/index.php/paranoa/article/view/24047 doi:10.18830/issn.1679-0944.n20.2018.06 |
op_doi |
https://doi.org/10.18830/issn.1679-0944.n20.2018.06 |
container_title |
Paranoá: cadernos de arquitetura e urbanismo |
container_issue |
20 |
_version_ |
1778517864850915328 |