The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions

The present study was conducted in order to evaluate efficiency of a personal body cooling system based on passive evaporative technologies and its effects on test subjects and their psycho-physiological suitability during exertional heat stress in hot environment. Performed results are based on con...

Full description

Bibliographic Details
Published in:Hemijska industrija
Main Authors: Karkalić, Radovan, Jovanović, Dalibor B., Radaković, Sonja S., Rajić, Dušan, Petrović, Biljana V., Ivanković, Negovan, Senić, Željko
Format: Article in Journal/Newspaper
Language:unknown
Published: Association of Chemical Engineers of Serbia 2015
Subjects:
Online Access:http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2888
https://doi.org/10.2298/HEMIND140705079K
http://TechnoRep.tmf.bg.ac.rs/bitstream/id/951/2885.pdf
id ftunivbelgradftm:oai:TechnoRep.tmf.bg.ac.rs:123456789/2888
record_format openpolar
spelling ftunivbelgradftm:oai:TechnoRep.tmf.bg.ac.rs:123456789/2888 2023-05-15T15:17:37+02:00 The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions Uticaj prsluka za hlađenje sa sistemom pasivnog isparavanja na nivo fiziološkog opterećenja radnika hemijske industrije u toploj sredini Karkalić, Radovan Jovanović, Dalibor B. Radaković, Sonja S. Rajić, Dušan Petrović, Biljana V. Ivanković, Negovan Senić, Željko 2015 http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2888 https://doi.org/10.2298/HEMIND140705079K http://TechnoRep.tmf.bg.ac.rs/bitstream/id/951/2885.pdf unknown Association of Chemical Engineers of Serbia info:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/34034/RS// 0367-598X http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2888 doi:10.2298/HEMIND140705079K http://TechnoRep.tmf.bg.ac.rs/bitstream/id/951/2885.pdf 2-s2.0-84953293337 000369523000001 openAccess https://creativecommons.org/licenses/by-nc-nd/4.0/ BY-NC-ND CC-BY-NC-ND Hemijska industrija chemical industry heat stress cooling vest working uniform physiological strain Hemijska industrija Toplotni stres Rashladni prsluk Radna odeća Fiziologija napora article publishedVersion 2015 ftunivbelgradftm https://doi.org/10.2298/HEMIND140705079K 2023-03-08T15:02:43Z The present study was conducted in order to evaluate efficiency of a personal body cooling system based on passive evaporative technologies and its effects on test subjects and their psycho-physiological suitability during exertional heat stress in hot environment. Performed results are based on conducted tests in climatic chamber in the Military Medical Academy Institute of Hygiene in Belgrade. Ten male test subjects were subjected to exertional heat stress test consisted of walking on motorized treadmill at a speed of 5 km/h in hot environment. Tests were performed with and without cooling system. As a physiological strain indicator the following parameters have been determined: mean skin temperature, tympanic temperature, heart rate and sweat rate. Results confirmed that cooling vest worn over the clothes was able to attenuate the physiological strain levels during exercise, when compared to identical exposure without the cooling system. Rad predstavlja rezultate naučnih istraživanja na polju efikasnosti sistema za hlađenje tela iz grupe pasivnih sistema na bazi isparavanja i njegov uticaj na fiziološku podobnost ljudi u uslovima izloženosti fizičkom naporu i ekstremno visokim temperaturama. Podaci i dobijeni rezultati zasnovani su na ispitivanjima sprovedenim u klimatskoj komori Instituta za higijenu VMA u Beogradu. Deset ispitanika muškog pola dobrovoljno je podvrgnuto testovima toplotnog opterećenja usled fizičkog napora, izazvanog hodanjem na pokretnoj traci sa brzinom hoda od 5 km/h, u toploj sredini (temperatura vazduha 40 °C). Testovi su realizovani sa ispitanicima srednjih godina (27.2±2.6), sličnih antropometrijskih parametara (74±7 kg, 184±9 cm), u varijanti nošenja radne odeće bez ikakvog rashladnog sistema (opcija NoCOOL) i uz upotrebu rashladnih prsluka za hlađenje tela, model Arctic Heat® (opcija ACOOL). Kao pokazatelji fiziološkog opterećenja određivane su: srednja temperatura kože (Tsk), timpanična temperatura (Tty) i frekvencija srčanog rada (HR), dok je intenzitet znojenja (SwR) izračunat ... Article in Journal/Newspaper Arctic TechnoRep - Faculty of Technology and Metallurgy Repository Arctic Hemijska industrija 69 6 587 594
institution Open Polar
collection TechnoRep - Faculty of Technology and Metallurgy Repository
op_collection_id ftunivbelgradftm
language unknown
topic chemical industry
heat stress
cooling vest
working uniform
physiological strain
Hemijska industrija
Toplotni stres
Rashladni prsluk
Radna odeća
Fiziologija napora
spellingShingle chemical industry
heat stress
cooling vest
working uniform
physiological strain
Hemijska industrija
Toplotni stres
Rashladni prsluk
Radna odeća
Fiziologija napora
Karkalić, Radovan
Jovanović, Dalibor B.
Radaković, Sonja S.
Rajić, Dušan
Petrović, Biljana V.
Ivanković, Negovan
Senić, Željko
The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
topic_facet chemical industry
heat stress
cooling vest
working uniform
physiological strain
Hemijska industrija
Toplotni stres
Rashladni prsluk
Radna odeća
Fiziologija napora
description The present study was conducted in order to evaluate efficiency of a personal body cooling system based on passive evaporative technologies and its effects on test subjects and their psycho-physiological suitability during exertional heat stress in hot environment. Performed results are based on conducted tests in climatic chamber in the Military Medical Academy Institute of Hygiene in Belgrade. Ten male test subjects were subjected to exertional heat stress test consisted of walking on motorized treadmill at a speed of 5 km/h in hot environment. Tests were performed with and without cooling system. As a physiological strain indicator the following parameters have been determined: mean skin temperature, tympanic temperature, heart rate and sweat rate. Results confirmed that cooling vest worn over the clothes was able to attenuate the physiological strain levels during exercise, when compared to identical exposure without the cooling system. Rad predstavlja rezultate naučnih istraživanja na polju efikasnosti sistema za hlađenje tela iz grupe pasivnih sistema na bazi isparavanja i njegov uticaj na fiziološku podobnost ljudi u uslovima izloženosti fizičkom naporu i ekstremno visokim temperaturama. Podaci i dobijeni rezultati zasnovani su na ispitivanjima sprovedenim u klimatskoj komori Instituta za higijenu VMA u Beogradu. Deset ispitanika muškog pola dobrovoljno je podvrgnuto testovima toplotnog opterećenja usled fizičkog napora, izazvanog hodanjem na pokretnoj traci sa brzinom hoda od 5 km/h, u toploj sredini (temperatura vazduha 40 °C). Testovi su realizovani sa ispitanicima srednjih godina (27.2±2.6), sličnih antropometrijskih parametara (74±7 kg, 184±9 cm), u varijanti nošenja radne odeće bez ikakvog rashladnog sistema (opcija NoCOOL) i uz upotrebu rashladnih prsluka za hlađenje tela, model Arctic Heat® (opcija ACOOL). Kao pokazatelji fiziološkog opterećenja određivane su: srednja temperatura kože (Tsk), timpanična temperatura (Tty) i frekvencija srčanog rada (HR), dok je intenzitet znojenja (SwR) izračunat ...
format Article in Journal/Newspaper
author Karkalić, Radovan
Jovanović, Dalibor B.
Radaković, Sonja S.
Rajić, Dušan
Petrović, Biljana V.
Ivanković, Negovan
Senić, Željko
author_facet Karkalić, Radovan
Jovanović, Dalibor B.
Radaković, Sonja S.
Rajić, Dušan
Petrović, Biljana V.
Ivanković, Negovan
Senić, Željko
author_sort Karkalić, Radovan
title The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
title_short The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
title_full The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
title_fullStr The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
title_full_unstemmed The influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
title_sort influence of the passive evaporative cooling vest on a chemical industry workers and physiological strain level in hot conditions
publisher Association of Chemical Engineers of Serbia
publishDate 2015
url http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2888
https://doi.org/10.2298/HEMIND140705079K
http://TechnoRep.tmf.bg.ac.rs/bitstream/id/951/2885.pdf
geographic Arctic
geographic_facet Arctic
genre Arctic
genre_facet Arctic
op_source Hemijska industrija
op_relation info:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/34034/RS//
0367-598X
http://TechnoRep.tmf.bg.ac.rs/handle/123456789/2888
doi:10.2298/HEMIND140705079K
http://TechnoRep.tmf.bg.ac.rs/bitstream/id/951/2885.pdf
2-s2.0-84953293337
000369523000001
op_rights openAccess
https://creativecommons.org/licenses/by-nc-nd/4.0/
BY-NC-ND
op_rightsnorm CC-BY-NC-ND
op_doi https://doi.org/10.2298/HEMIND140705079K
container_title Hemijska industrija
container_volume 69
container_issue 6
container_start_page 587
op_container_end_page 594
_version_ 1766347856008970240