In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation

Background: Cryoablation to achieve pulmonary vein (PV) isolation has become one of the standard approaches for atrial fibrillation (AF) ablation. The Arctic Front series cryoballoon and Achieve circular mapping catheter (Medtronic) inherently possess design defects that have been associated with un...

Full description

Bibliographic Details
Published in:Journal of Interventional Cardiac Electrophysiology
Main Authors: Bai, Rong, Liao, Yu, Wang, Xunzhang, Rosenthal, Kevin, Vessey, Justin, Mazor, Meital, Su, Wilber
Other Authors: College of Medicine, University of Arizona
Format: Article in Journal/Newspaper
Language:English
Published: Springer 2024
Subjects:
Online Access:http://hdl.handle.net/10150/674789
https://doi.org/10.1007/s10840-024-01836-5
id ftunivarizona:oai:repository.arizona.edu:10150/674789
record_format openpolar
spelling ftunivarizona:oai:repository.arizona.edu:10150/674789 2024-09-30T14:31:43+00:00 In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation Bai, Rong Liao, Yu Wang, Xunzhang Rosenthal, Kevin Vessey, Justin Mazor, Meital Su, Wilber College of Medicine, University of Arizona 2024-06-03 http://hdl.handle.net/10150/674789 https://doi.org/10.1007/s10840-024-01836-5 en eng Springer Bai, R., Liao, Y., Wang, X., Rosenthal, K., Vessey, J., Mazor, M., & Su, W. (2024). In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 1-10. 38831168 doi:10.1007/s10840-024-01836-5 http://hdl.handle.net/10150/674789 1572-8595 Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing © 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature. http://rightsstatements.org/vocab/InC/1.0/ Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing Netherlands atrial fibrillation cryoablation Cryoballoon Pulmonary vein isolation Article 2024 ftunivarizona https://doi.org/10.1007/s10840-024-01836-5 2024-09-17T00:06:46Z Background: Cryoablation to achieve pulmonary vein (PV) isolation has become one of the standard approaches for atrial fibrillation (AF) ablation. The Arctic Front series cryoballoon and Achieve circular mapping catheter (Medtronic) inherently possess design defects that have been associated with unfavorite clinical outcomes. Lately, a new cryoablation system (Nordica Cryoablation System, Synaptic Medical) was developed with improved design of the cryoballoon and circular mapping catheter to address the inadequacies of current cryoablation technology. An animal study was conducted to test the efficacy and safety in performing PVI with the Nordica Cryoablation System. Methods: Pulmonary vein isolation with the Nordica Cryoablation System was performed on 12 PVs of six healthy canines. Acute PVI and peri-procedural complications were recorded. All animals underwent a repeat EP study at least 4 weeks after index procedures followed by pathological and histological assessments of the heart and collateral/downstream organs after planned euthanasia. Results: Acute PV isolation was achieved in all targeted PVs with 50% of PVs being isolated with a single cryoablation application. There were no major peri-procedural complications or device malfunction events. All PVs remained isolated after 29–30 days follow-up. Histological examination showed transmural cryo-lesions at treated sites with minimal inflammation, neovascularization, and neointima formation but no significant injury to adjacent tissue or embolization in downstream organs. Conclusion: Acute and durable PVI can be achieved by using the novel Nordica Cryoablation System. Ablation with this new cryoablation system is associated with transmural lesions at targeted myocardium but creates no injury to the collateral tissues or downstream organs. 12 month embargo; published 03 June 2024 This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have ... Article in Journal/Newspaper Arctic The University of Arizona: UA Campus Repository Arctic Journal of Interventional Cardiac Electrophysiology
institution Open Polar
collection The University of Arizona: UA Campus Repository
op_collection_id ftunivarizona
language English
topic atrial fibrillation
cryoablation
Cryoballoon
Pulmonary vein isolation
spellingShingle atrial fibrillation
cryoablation
Cryoballoon
Pulmonary vein isolation
Bai, Rong
Liao, Yu
Wang, Xunzhang
Rosenthal, Kevin
Vessey, Justin
Mazor, Meital
Su, Wilber
In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation
topic_facet atrial fibrillation
cryoablation
Cryoballoon
Pulmonary vein isolation
description Background: Cryoablation to achieve pulmonary vein (PV) isolation has become one of the standard approaches for atrial fibrillation (AF) ablation. The Arctic Front series cryoballoon and Achieve circular mapping catheter (Medtronic) inherently possess design defects that have been associated with unfavorite clinical outcomes. Lately, a new cryoablation system (Nordica Cryoablation System, Synaptic Medical) was developed with improved design of the cryoballoon and circular mapping catheter to address the inadequacies of current cryoablation technology. An animal study was conducted to test the efficacy and safety in performing PVI with the Nordica Cryoablation System. Methods: Pulmonary vein isolation with the Nordica Cryoablation System was performed on 12 PVs of six healthy canines. Acute PVI and peri-procedural complications were recorded. All animals underwent a repeat EP study at least 4 weeks after index procedures followed by pathological and histological assessments of the heart and collateral/downstream organs after planned euthanasia. Results: Acute PV isolation was achieved in all targeted PVs with 50% of PVs being isolated with a single cryoablation application. There were no major peri-procedural complications or device malfunction events. All PVs remained isolated after 29–30 days follow-up. Histological examination showed transmural cryo-lesions at treated sites with minimal inflammation, neovascularization, and neointima formation but no significant injury to adjacent tissue or embolization in downstream organs. Conclusion: Acute and durable PVI can be achieved by using the novel Nordica Cryoablation System. Ablation with this new cryoablation system is associated with transmural lesions at targeted myocardium but creates no injury to the collateral tissues or downstream organs. 12 month embargo; published 03 June 2024 This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have ...
author2 College of Medicine, University of Arizona
format Article in Journal/Newspaper
author Bai, Rong
Liao, Yu
Wang, Xunzhang
Rosenthal, Kevin
Vessey, Justin
Mazor, Meital
Su, Wilber
author_facet Bai, Rong
Liao, Yu
Wang, Xunzhang
Rosenthal, Kevin
Vessey, Justin
Mazor, Meital
Su, Wilber
author_sort Bai, Rong
title In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation
title_short In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation
title_full In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation
title_fullStr In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation
title_full_unstemmed In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation
title_sort in vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation
publisher Springer
publishDate 2024
url http://hdl.handle.net/10150/674789
https://doi.org/10.1007/s10840-024-01836-5
geographic Arctic
geographic_facet Arctic
genre Arctic
genre_facet Arctic
op_source Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
Netherlands
op_relation Bai, R., Liao, Y., Wang, X., Rosenthal, K., Vessey, J., Mazor, M., & Su, W. (2024). In vivo safety and pulmonary vein isolation performance of a new cryoballoon for the treatment of atrial fibrillation. Journal of Interventional Cardiac Electrophysiology, 1-10.
38831168
doi:10.1007/s10840-024-01836-5
http://hdl.handle.net/10150/674789
1572-8595
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
op_rights © 2024. The Author(s), under exclusive licence to Springer Science+Business Media, LLC, part of Springer Nature.
http://rightsstatements.org/vocab/InC/1.0/
op_doi https://doi.org/10.1007/s10840-024-01836-5
container_title Journal of Interventional Cardiac Electrophysiology
_version_ 1811636126265376768