Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography
RESUMEN: En este trabajo se presenta la validación del procedimiento analítico que permite determinar las concentraciones de Benceno (B), Tolueno (T), Etilbenceno (E) y Xilenos (X), compuestos conocidos como BTEX, presentes en el aire y adsorbidos sobre carbón activado, usando el método de adición d...
Published in: | Revista Facultad de Ingeniería Universidad de Antioquia |
---|---|
Main Authors: | , |
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
Universidad de Antioquia, Facultad de Ingeniería
2016
|
Subjects: | |
Online Access: | http://hdl.handle.net/10495/5900 https://doi.org/10.17533/udea.redin.n79a13 |
id |
ftunivantioquia:oai:bibliotecadigital.udea.edu.co:10495/5900 |
---|---|
record_format |
openpolar |
institution |
Open Polar |
collection |
Universidad de Antioquia (UdeA): Institutional Repository |
op_collection_id |
ftunivantioquia |
language |
English |
topic |
Almacenamiento de hidrocarburos Muestras de aire Adsorción de carbón activado Cromatografía de gases Compuestos orgánicos volátiles Benceno Tolueno Etilbenceno Xilenos Hidrocarburos |
spellingShingle |
Almacenamiento de hidrocarburos Muestras de aire Adsorción de carbón activado Cromatografía de gases Compuestos orgánicos volátiles Benceno Tolueno Etilbenceno Xilenos Hidrocarburos Correa Ochoa, Mauricio Andrés Saldarriaga Molina, Julio César Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography |
topic_facet |
Almacenamiento de hidrocarburos Muestras de aire Adsorción de carbón activado Cromatografía de gases Compuestos orgánicos volátiles Benceno Tolueno Etilbenceno Xilenos Hidrocarburos |
description |
RESUMEN: En este trabajo se presenta la validación del procedimiento analítico que permite determinar las concentraciones de Benceno (B), Tolueno (T), Etilbenceno (E) y Xilenos (X), compuestos conocidos como BTEX, presentes en el aire y adsorbidos sobre carbón activado, usando el método de adición de estándar interno (Fluorobenceno) para la cuantificación. En el proceso se empleó carbón activado de referencia para la validación y carbón granular (CGC) a base de coco para la construcción de los captadores pasivos, empleados en la toma de muestras en exteriores o aire ambiente. El material CGC fue seleccionado a partir de su capacidad de recuperación de BTEX, con un promedio 89,1% para todos los analitos. En la investigación se evaluó la presencia de BTEX en muestras de aire, tomadas en una vía de seis carriles y caracterizada, además, por ser de alto flujo vehicular en la ciudad de Medellín (Antioquia, Colombia). Los captadores empleados, fueron ubicados en pares por punto (en siete franjas transversales de la vía: andenes oriental, central y occidental, y a alturas que oscilaron entre los 2,50 y 3,00 metros a nivel de piso), dentro de una carcasa especial para su protección. El número de estaciones totales fue de veintiuno (21) en un trayecto de 3 km, para un total de 21 muestras recolectadas con tiempos de exposición de 28 días. El procedimiento de desorción de los analitos se realizó con disulfuro de carbono como solvente de extracción y en el análisis cromatográfico de gases se realizó (por triplicado) empleando un detector de ionización de llama (FID). Se usó, además, una columna cromatográfica HP- INNOWAX. El tiempo de corrido empleado fue de 18,5 minutos, usando Helio ultra puro, 99,99% de pureza como gas de arrastre y la cuantificación se llevó a cabo en el extracto líquido en términos de concentración (µg/mL). En la investigación se pudo validar la metodología, obteniendo porcentajes de recuperación que oscilaron entre el 75,0 y el 98,2 % para todos los analitos y los límites de cuantificación en µg/mL ... |
format |
Article in Journal/Newspaper |
author |
Correa Ochoa, Mauricio Andrés Saldarriaga Molina, Julio César |
author_facet |
Correa Ochoa, Mauricio Andrés Saldarriaga Molina, Julio César |
author_sort |
Correa Ochoa, Mauricio Andrés |
title |
Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography |
title_short |
Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography |
title_full |
Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography |
title_fullStr |
Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography |
title_full_unstemmed |
Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography |
title_sort |
validation of a methodology to determine benzene, toluene, ethylbenzene, and xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by gc/ fid chromatography |
publisher |
Universidad de Antioquia, Facultad de Ingeniería |
publishDate |
2016 |
url |
http://hdl.handle.net/10495/5900 https://doi.org/10.17533/udea.redin.n79a13 |
long_lat |
ENVELOPE(-65.939,-65.939,-68.664,-68.664) |
geographic |
Fid Referencia |
geographic_facet |
Fid Referencia |
genre |
Andenes |
genre_facet |
Andenes |
op_relation |
Rev. Fac. Ing. Univ. Antioquia M. L. Gallego, M. A. Correa and J. C. Saldarriaga, "Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography", Rev. Fac. Ing. Univ. Antioquia, no. 79, pp. 138-149, 2016. 0120-6230 http://hdl.handle.net/10495/5900 doi:10.17533/udea.redin.n79a13 2422-2844 |
op_rights |
Atribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO) info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/co/ http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by-nc-sa/4.0/ |
op_rightsnorm |
CC-BY-NC-SA |
op_doi |
https://doi.org/10.17533/udea.redin.n79a13 |
container_title |
Revista Facultad de Ingeniería Universidad de Antioquia |
container_issue |
79 |
_version_ |
1766385606441566208 |
spelling |
ftunivantioquia:oai:bibliotecadigital.udea.edu.co:10495/5900 2023-05-15T13:25:29+02:00 Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography Validación de una metodología para la determinación de la concentración de Benceno, Tolueno, Etilbenceno y Xilenos, presentes en muestras aire y adsorbidos en captadores pasivos de carbón activado, mediante cromatografía GC/FID Correa Ochoa, Mauricio Andrés Saldarriaga Molina, Julio César 2016 11 application/pdf http://hdl.handle.net/10495/5900 https://doi.org/10.17533/udea.redin.n79a13 eng eng Universidad de Antioquia, Facultad de Ingeniería Grupo de Ingeniería y Gestión Ambiental (GIGA) Medellín, Colombia Rev. Fac. Ing. Univ. Antioquia M. L. Gallego, M. A. Correa and J. C. Saldarriaga, "Validation of a methodology to determine Benzene, Toluene, Ethylbenzene, and Xylenes concentration present in the air and adsorbed in activated charcoal passive samplers by GC/ FID chromatography", Rev. Fac. Ing. Univ. Antioquia, no. 79, pp. 138-149, 2016. 0120-6230 http://hdl.handle.net/10495/5900 doi:10.17533/udea.redin.n79a13 2422-2844 Atribución-NoComercial-CompartirIgual 2.5 Colombia (CC BY-NC-SA 2.5 CO) info:eu-repo/semantics/openAccess https://creativecommons.org/licenses/by-nc-sa/2.5/co/ http://purl.org/coar/access_right/c_abf2 https://creativecommons.org/licenses/by-nc-sa/4.0/ CC-BY-NC-SA Almacenamiento de hidrocarburos Muestras de aire Adsorción de carbón activado Cromatografía de gases Compuestos orgánicos volátiles Benceno Tolueno Etilbenceno Xilenos Hidrocarburos info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion http://purl.org/coar/resource_type/c_2df8fbb1 https://purl.org/redcol/resource_type/ART Artículo de investigación 2016 ftunivantioquia https://doi.org/10.17533/udea.redin.n79a13 2022-12-19T14:22:00Z RESUMEN: En este trabajo se presenta la validación del procedimiento analítico que permite determinar las concentraciones de Benceno (B), Tolueno (T), Etilbenceno (E) y Xilenos (X), compuestos conocidos como BTEX, presentes en el aire y adsorbidos sobre carbón activado, usando el método de adición de estándar interno (Fluorobenceno) para la cuantificación. En el proceso se empleó carbón activado de referencia para la validación y carbón granular (CGC) a base de coco para la construcción de los captadores pasivos, empleados en la toma de muestras en exteriores o aire ambiente. El material CGC fue seleccionado a partir de su capacidad de recuperación de BTEX, con un promedio 89,1% para todos los analitos. En la investigación se evaluó la presencia de BTEX en muestras de aire, tomadas en una vía de seis carriles y caracterizada, además, por ser de alto flujo vehicular en la ciudad de Medellín (Antioquia, Colombia). Los captadores empleados, fueron ubicados en pares por punto (en siete franjas transversales de la vía: andenes oriental, central y occidental, y a alturas que oscilaron entre los 2,50 y 3,00 metros a nivel de piso), dentro de una carcasa especial para su protección. El número de estaciones totales fue de veintiuno (21) en un trayecto de 3 km, para un total de 21 muestras recolectadas con tiempos de exposición de 28 días. El procedimiento de desorción de los analitos se realizó con disulfuro de carbono como solvente de extracción y en el análisis cromatográfico de gases se realizó (por triplicado) empleando un detector de ionización de llama (FID). Se usó, además, una columna cromatográfica HP- INNOWAX. El tiempo de corrido empleado fue de 18,5 minutos, usando Helio ultra puro, 99,99% de pureza como gas de arrastre y la cuantificación se llevó a cabo en el extracto líquido en términos de concentración (µg/mL). En la investigación se pudo validar la metodología, obteniendo porcentajes de recuperación que oscilaron entre el 75,0 y el 98,2 % para todos los analitos y los límites de cuantificación en µg/mL ... Article in Journal/Newspaper Andenes Universidad de Antioquia (UdeA): Institutional Repository Fid ENVELOPE(-65.939,-65.939,-68.664,-68.664) Referencia Revista Facultad de Ingeniería Universidad de Antioquia 79 |