Avaliação mecânica da estabilidade de pilares cone Morse com diferentes características de fabricação: estudo in vitro

The aim of this study was to compare quantitatively and qualitatively the retention and adaptation of four types of commercially available implantabutment connections and their different characteristics. A total of 40 Morse taper implants (CM) were used (20 Titamax CM EX 4.0 mm x 11 mm Neodent and 2...

Full description

Bibliographic Details
Main Author: Moura, Marcos Boaventura de
Other Authors: Araújo, Cleudmar Amaral de, http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4782336A0, Simamoto Júnior, Paulo Cézar, http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4770653D6, Neves, Flávio Domingues das, http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4707355A8, Guimarães, George Furtado, http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K8705634D0
Format: Thesis
Language:Portuguese
Published: Universidade Federal de Uberlândia 2017
Subjects:
MEV
SEM
Online Access:https://repositorio.ufu.br/handle/123456789/18228
https://doi.org/10.14393/ufu.di.2017.152
Description
Summary:The aim of this study was to compare quantitatively and qualitatively the retention and adaptation of four types of commercially available implantabutment connections and their different characteristics. A total of 40 Morse taper implants (CM) were used (20 Titamax CM EX 4.0 mm x 11 mm Neodent and 20 Strong SW Morse 4.5 x 10 mm SIN), with 40 abutments installed on the implants, with 10 abutments Neodent solid (NS), 10 SIN (SS) solid abutments, 10 neodent bolt (NP) abutments and 10 SIN screw bolts (SP). The implants were embedded in polystyrene resin (Aerojet) using a standardized device and the prosthetic abutments were installed with manufacturer recommended torques. The tightening and loosening torques of each abutment were evaluated in two moments: Initial moment (I): the torque was applied and after 3 minutes the release was performed; Final torque (F): Tightening and loosening torque after mechanical cycling. Four groups (n = 10) were formed: NSI (Neodent initial solid) and NSF (Neodent final solid) - (32 Ncm of tightening torque at both moments), NPI (Neodent initial passer) and NPF (Neodent final passer) - (tightening torque of 15 Ncm at both times), SSI (SIN initial solid) and SSF (final solid SIN); SPI (SIN initial through) and SPF (SIN final through) - (20 Ncm of tightening torque at both times). Tightening and loosening torques were performed using the MK Control torque wrench coupled to the Lynx acquisition system. Prior to the mechanical cycling, 40 nickel-chromium crowns were made, which were cemented to the corresponding columns using provisional cement based on calcium hydroxide composition. Then the samples were submitted to a mechanical cycling test, with a dynamic load of 50 N, frequency of 2 Hz and 37°C, totaling 1,200,000 masticatory cycles (5 years of mastication). The samples were positioned in a 30º angle on the cycling machine platform, as recommended by standard ISO 14801. After the mechanical cycling, the screws were loosened. Before and after the mechanical cycling test, precision ...