Energibalans i det nya badhuset i Kiruna
One of the goals in this thesis is to make an energy balance for the new bathhouse in Kiruna. Another goal is to investigate whether it is possible to environmentally certify the building with bathhouse operations. Additional goal is to check whether the Upphandlingsmyndighetens sustainability crite...
Main Author: | |
---|---|
Format: | Bachelor Thesis |
Language: | Swedish |
Published: |
Umeå universitet, Institutionen för tillämpad fysik och elektronik
2019
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-164106 |
id |
ftumeauniv:oai:DiVA.org:umu-164106 |
---|---|
record_format |
openpolar |
spelling |
ftumeauniv:oai:DiVA.org:umu-164106 2023-10-09T21:53:12+02:00 Energibalans i det nya badhuset i Kiruna Energy balance in the new bathhouse in Kiruna Forsvall, Anna-Sara 2019 application/pdf http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-164106 swe swe Umeå universitet, Institutionen för tillämpad fysik och elektronik http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-164106 info:eu-repo/semantics/openAccess Badhus energi energibalans simhall Energy Engineering Energiteknik Student thesis info:eu-repo/semantics/bachelorThesis text 2019 ftumeauniv 2023-09-22T13:51:43Z One of the goals in this thesis is to make an energy balance for the new bathhouse in Kiruna. Another goal is to investigate whether it is possible to environmentally certify the building with bathhouse operations. Additional goal is to check whether the Upphandlingsmyndighetens sustainability criteria for bathhouses are possible to use when building bathhouses. The background to this project is that Kiruna are getting a new bathhouse because the old one is to be demolished. What has been investigated in this project is the criteria for environmental certifications and whether a bathhouse business can meet those criteria. The indicator that has been of most interest is energy use. The energy balance was made through measurements and conversations with experts from the consultant company We group and by simulating the energy balance using the software VIP Energy. The work has resulted in an energy balance being created. A comparison is made between only the building and the building with a bathhouse activity. The environmental certifications were investigated, and they were found that none of the selected environmental certifications worked for the building with bathhouse activities since they use too much energy. The National agency for public procurement sustainability criteria for bathhouses generally works but need to be adjusted to be more useful.work but should be used as an aid until the criteria are completed. The energy balance showed that the bathhouse with operations had an energy consumption of 323.9 kWh / (m2, Atemp) in one year. The bath house without activity had an energy consumption of 44.3 kWh / (m2, Atemp) in one year. The building with bathhouse operations has an energy performance premiere energy of 351.5 kWh / (m2, Atemp) in one year and the building without bathhouse operations is 61.1 kWh / (m2, Atemp) in a year. The requirement from BBR on energy performance is 125.5 kWh / (m2, Atemp) in a year. Bachelor Thesis Kiruna Umeå University: Publications (DiVA) Kiruna |
institution |
Open Polar |
collection |
Umeå University: Publications (DiVA) |
op_collection_id |
ftumeauniv |
language |
Swedish |
topic |
Badhus energi energibalans simhall Energy Engineering Energiteknik |
spellingShingle |
Badhus energi energibalans simhall Energy Engineering Energiteknik Forsvall, Anna-Sara Energibalans i det nya badhuset i Kiruna |
topic_facet |
Badhus energi energibalans simhall Energy Engineering Energiteknik |
description |
One of the goals in this thesis is to make an energy balance for the new bathhouse in Kiruna. Another goal is to investigate whether it is possible to environmentally certify the building with bathhouse operations. Additional goal is to check whether the Upphandlingsmyndighetens sustainability criteria for bathhouses are possible to use when building bathhouses. The background to this project is that Kiruna are getting a new bathhouse because the old one is to be demolished. What has been investigated in this project is the criteria for environmental certifications and whether a bathhouse business can meet those criteria. The indicator that has been of most interest is energy use. The energy balance was made through measurements and conversations with experts from the consultant company We group and by simulating the energy balance using the software VIP Energy. The work has resulted in an energy balance being created. A comparison is made between only the building and the building with a bathhouse activity. The environmental certifications were investigated, and they were found that none of the selected environmental certifications worked for the building with bathhouse activities since they use too much energy. The National agency for public procurement sustainability criteria for bathhouses generally works but need to be adjusted to be more useful.work but should be used as an aid until the criteria are completed. The energy balance showed that the bathhouse with operations had an energy consumption of 323.9 kWh / (m2, Atemp) in one year. The bath house without activity had an energy consumption of 44.3 kWh / (m2, Atemp) in one year. The building with bathhouse operations has an energy performance premiere energy of 351.5 kWh / (m2, Atemp) in one year and the building without bathhouse operations is 61.1 kWh / (m2, Atemp) in a year. The requirement from BBR on energy performance is 125.5 kWh / (m2, Atemp) in a year. |
format |
Bachelor Thesis |
author |
Forsvall, Anna-Sara |
author_facet |
Forsvall, Anna-Sara |
author_sort |
Forsvall, Anna-Sara |
title |
Energibalans i det nya badhuset i Kiruna |
title_short |
Energibalans i det nya badhuset i Kiruna |
title_full |
Energibalans i det nya badhuset i Kiruna |
title_fullStr |
Energibalans i det nya badhuset i Kiruna |
title_full_unstemmed |
Energibalans i det nya badhuset i Kiruna |
title_sort |
energibalans i det nya badhuset i kiruna |
publisher |
Umeå universitet, Institutionen för tillämpad fysik och elektronik |
publishDate |
2019 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-164106 |
geographic |
Kiruna |
geographic_facet |
Kiruna |
genre |
Kiruna |
genre_facet |
Kiruna |
op_relation |
http://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-164106 |
op_rights |
info:eu-repo/semantics/openAccess |
_version_ |
1779316448605241344 |