Fuktbelastning i takkonstruktioner med perforerad ångspärr

Moisture in roof constructions is currently a major concern in the building industry, especially in Sweden where the climate is often wet and the dry season short. In order to avoid these problems in the future there needs to be a greater understanding and focus on building techniques that prevent m...

Full description

Bibliographic Details
Main Authors: Georgsdottir, Tina, Sawirs, Emely
Format: Other/Unknown Material
Language:Swedish
Published: Lunds universitet/Utbildningar i Helsingborg 2012
Subjects:
Online Access:http://lup.lub.lu.se/student-papers/record/2797821
id ftulundlupsp:oai:lup-student-papers.lub.lu.se:2797821
record_format openpolar
spelling ftulundlupsp:oai:lup-student-papers.lub.lu.se:2797821 2023-07-30T04:04:48+02:00 Fuktbelastning i takkonstruktioner med perforerad ångspärr Georgsdottir, Tina Sawirs, Emely 2012 application/pdf http://lup.lub.lu.se/student-papers/record/2797821 swe swe Lunds universitet/Utbildningar i Helsingborg http://lup.lub.lu.se/student-papers/record/2797821 wufi ångspärr variabel ångbroms isover dosmodellen mögelpåväxt Technology and Engineering M2 2012 ftulundlupsp 2023-07-11T20:06:29Z Moisture in roof constructions is currently a major concern in the building industry, especially in Sweden where the climate is often wet and the dry season short. In order to avoid these problems in the future there needs to be a greater understanding and focus on building techniques that prevent mold problems. Crucial to mold prevention is the vapor retarder, which is relied heavily upon in roof construction in order to prevent the airflow between indoor spaces and the construction itself. In most theoretical models this retarder is viewed as flawless, however this is often not the reality. The purpose of this study is to investigate the moisture and related mold problems associated with different degrees of perforation in the vapor retarder in two different types of roof constructions, a non-ventilated pitched roof and a traditional ventilated pitched roof. The constructions are located in Lund and Luleå and two different vapor retarders are tested, so there are four different constructions for each location: Ventilated inclined roof with glass wool slabs and Isover Vario KM Duplex UV (S.201) Ventilated inclined roof with glass wool slabs and Isover Vapor retarder (S201) Non-ventilated inclined roof with glass wool slabs and Isover Vario KM Duplex UV (S.204) Non-ventilated inclined roof with glass wool slabs and Isover Vapor retarder (S.204) Simulations have been made in the program WUFI Pro 5.1. Results from WUFI have been analyzed in a mold dosage model developed at Lunds Technical University. The results of simulations performed in this study show that the traditional ventilated pitched roof performs better than the non-ventilated pitched roof when a perforation exists in the vapor retarder. Generally the smallest of the studied perforations (d=5 mm per m^2 roof area) is acceptable in the ventilated pitched roof but larger holes lead to extensive mold growth. In the non-ventilated compact roof a hole in the vapor retarder cannot be accepted according to calculations in this study. The study also shows that ... Other/Unknown Material Luleå Luleå Luleå Lund University Publications Student Papers (LUP-SP)
institution Open Polar
collection Lund University Publications Student Papers (LUP-SP)
op_collection_id ftulundlupsp
language Swedish
topic wufi
ångspärr
variabel ångbroms
isover
dosmodellen
mögelpåväxt
Technology and Engineering
spellingShingle wufi
ångspärr
variabel ångbroms
isover
dosmodellen
mögelpåväxt
Technology and Engineering
Georgsdottir, Tina
Sawirs, Emely
Fuktbelastning i takkonstruktioner med perforerad ångspärr
topic_facet wufi
ångspärr
variabel ångbroms
isover
dosmodellen
mögelpåväxt
Technology and Engineering
description Moisture in roof constructions is currently a major concern in the building industry, especially in Sweden where the climate is often wet and the dry season short. In order to avoid these problems in the future there needs to be a greater understanding and focus on building techniques that prevent mold problems. Crucial to mold prevention is the vapor retarder, which is relied heavily upon in roof construction in order to prevent the airflow between indoor spaces and the construction itself. In most theoretical models this retarder is viewed as flawless, however this is often not the reality. The purpose of this study is to investigate the moisture and related mold problems associated with different degrees of perforation in the vapor retarder in two different types of roof constructions, a non-ventilated pitched roof and a traditional ventilated pitched roof. The constructions are located in Lund and Luleå and two different vapor retarders are tested, so there are four different constructions for each location: Ventilated inclined roof with glass wool slabs and Isover Vario KM Duplex UV (S.201) Ventilated inclined roof with glass wool slabs and Isover Vapor retarder (S201) Non-ventilated inclined roof with glass wool slabs and Isover Vario KM Duplex UV (S.204) Non-ventilated inclined roof with glass wool slabs and Isover Vapor retarder (S.204) Simulations have been made in the program WUFI Pro 5.1. Results from WUFI have been analyzed in a mold dosage model developed at Lunds Technical University. The results of simulations performed in this study show that the traditional ventilated pitched roof performs better than the non-ventilated pitched roof when a perforation exists in the vapor retarder. Generally the smallest of the studied perforations (d=5 mm per m^2 roof area) is acceptable in the ventilated pitched roof but larger holes lead to extensive mold growth. In the non-ventilated compact roof a hole in the vapor retarder cannot be accepted according to calculations in this study. The study also shows that ...
format Other/Unknown Material
author Georgsdottir, Tina
Sawirs, Emely
author_facet Georgsdottir, Tina
Sawirs, Emely
author_sort Georgsdottir, Tina
title Fuktbelastning i takkonstruktioner med perforerad ångspärr
title_short Fuktbelastning i takkonstruktioner med perforerad ångspärr
title_full Fuktbelastning i takkonstruktioner med perforerad ångspärr
title_fullStr Fuktbelastning i takkonstruktioner med perforerad ångspärr
title_full_unstemmed Fuktbelastning i takkonstruktioner med perforerad ångspärr
title_sort fuktbelastning i takkonstruktioner med perforerad ångspärr
publisher Lunds universitet/Utbildningar i Helsingborg
publishDate 2012
url http://lup.lub.lu.se/student-papers/record/2797821
genre Luleå
Luleå
Luleå
genre_facet Luleå
Luleå
Luleå
op_relation http://lup.lub.lu.se/student-papers/record/2797821
_version_ 1772816391444889600