Development of an optical scanner for Dome Fuji II ice core project
An optical scanner for stratigraphical study was developed for the Dome Fuji ice core project II. The optical scanner measures two-dimensional light scattering intensities and records optical structures of ice cores. We developed the scanner hardware and control software. The line scanner is control...
Main Authors: | , , , , , , , |
---|---|
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
National Institute of Polar Research
2003
|
Subjects: | |
Online Access: | https://doi.org/10.15094/00009270 https://doaj.org/article/993e4a2f011548acb094e1b54c3d5c89 |
id |
fttriple:oai:gotriple.eu:oai:doaj.org/article:993e4a2f011548acb094e1b54c3d5c89 |
---|---|
record_format |
openpolar |
spelling |
fttriple:oai:gotriple.eu:oai:doaj.org/article:993e4a2f011548acb094e1b54c3d5c89 2023-05-15T14:04:01+02:00 Development of an optical scanner for Dome Fuji II ice core project Morimasa Takata Yoshinori Iizuka Hitoshi Shoji Atsushi Miyamoto Sepp Kipfstuhl Takeo Hondoh Shuji Fujita Yoshiyuki Fujii 2003-11-01 https://doi.org/10.15094/00009270 https://doaj.org/article/993e4a2f011548acb094e1b54c3d5c89 en other eng National Institute of Polar Research doi:10.15094/00009270 0085-7289 2432-079X https://doaj.org/article/993e4a2f011548acb094e1b54c3d5c89 undefined Antarctic Record, Vol 47, Iss 3, Pp 358-337 (2003) geo envir Journal Article https://vocabularies.coar-repositories.org/resource_types/c_6501/ 2003 fttriple https://doi.org/10.15094/00009270 2023-01-22T19:14:08Z An optical scanner for stratigraphical study was developed for the Dome Fuji ice core project II. The optical scanner measures two-dimensional light scattering intensities and records optical structures of ice cores. We developed the scanner hardware and control software. The line scanner is controlled by a personal computer and is constructed for automatic measurement. The sliding speed of the scanner is about 5mm per second and, therefore, one ice core sample with a standard length for our sample processes (1.5m long) can be measured within about six minutes. The line scanner was transported to Dome Fuji Station, Antarctica, by the wintering party of the 44th Japanese Antarctic Research Expedition (JARE-44), and will be used for Dome Fuji II ice core measurement by the JARE-45 summer party and successive parties. Article in Journal/Newspaper Antarc* Antarctic Antarctica ice core Unknown Antarctic Dome Fuji ENVELOPE(39.700,39.700,-77.317,-77.317) Dome Fuji Station ENVELOPE(39.703,39.703,-77.317,-77.317) |
institution |
Open Polar |
collection |
Unknown |
op_collection_id |
fttriple |
language |
English |
topic |
geo envir |
spellingShingle |
geo envir Morimasa Takata Yoshinori Iizuka Hitoshi Shoji Atsushi Miyamoto Sepp Kipfstuhl Takeo Hondoh Shuji Fujita Yoshiyuki Fujii Development of an optical scanner for Dome Fuji II ice core project |
topic_facet |
geo envir |
description |
An optical scanner for stratigraphical study was developed for the Dome Fuji ice core project II. The optical scanner measures two-dimensional light scattering intensities and records optical structures of ice cores. We developed the scanner hardware and control software. The line scanner is controlled by a personal computer and is constructed for automatic measurement. The sliding speed of the scanner is about 5mm per second and, therefore, one ice core sample with a standard length for our sample processes (1.5m long) can be measured within about six minutes. The line scanner was transported to Dome Fuji Station, Antarctica, by the wintering party of the 44th Japanese Antarctic Research Expedition (JARE-44), and will be used for Dome Fuji II ice core measurement by the JARE-45 summer party and successive parties. |
format |
Article in Journal/Newspaper |
author |
Morimasa Takata Yoshinori Iizuka Hitoshi Shoji Atsushi Miyamoto Sepp Kipfstuhl Takeo Hondoh Shuji Fujita Yoshiyuki Fujii |
author_facet |
Morimasa Takata Yoshinori Iizuka Hitoshi Shoji Atsushi Miyamoto Sepp Kipfstuhl Takeo Hondoh Shuji Fujita Yoshiyuki Fujii |
author_sort |
Morimasa Takata |
title |
Development of an optical scanner for Dome Fuji II ice core project |
title_short |
Development of an optical scanner for Dome Fuji II ice core project |
title_full |
Development of an optical scanner for Dome Fuji II ice core project |
title_fullStr |
Development of an optical scanner for Dome Fuji II ice core project |
title_full_unstemmed |
Development of an optical scanner for Dome Fuji II ice core project |
title_sort |
development of an optical scanner for dome fuji ii ice core project |
publisher |
National Institute of Polar Research |
publishDate |
2003 |
url |
https://doi.org/10.15094/00009270 https://doaj.org/article/993e4a2f011548acb094e1b54c3d5c89 |
long_lat |
ENVELOPE(39.700,39.700,-77.317,-77.317) ENVELOPE(39.703,39.703,-77.317,-77.317) |
geographic |
Antarctic Dome Fuji Dome Fuji Station |
geographic_facet |
Antarctic Dome Fuji Dome Fuji Station |
genre |
Antarc* Antarctic Antarctica ice core |
genre_facet |
Antarc* Antarctic Antarctica ice core |
op_source |
Antarctic Record, Vol 47, Iss 3, Pp 358-337 (2003) |
op_relation |
doi:10.15094/00009270 0085-7289 2432-079X https://doaj.org/article/993e4a2f011548acb094e1b54c3d5c89 |
op_rights |
undefined |
op_doi |
https://doi.org/10.15094/00009270 |
_version_ |
1766274945689583616 |