Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions

Objectives: To evaluate the ability of an alignment jig/saw guide to reproduce appropriate osteotomy positions in the tibial plateau leveling osteotomy (TPLO) in the dog. Methods: Lateral radiographs of 65 clinical TPLO procedures using an alignment jig and freehand osteotomy performed by experience...

Full description

Bibliographic Details
Main Authors: Mariano, Abigail D., Kowaleski, Michael P., Boudrieau, Randy J.
Format: Dataset
Language:English
Published: Dryad 2017
Subjects:
Online Access:https://doi.org/10.5061/dryad.5f71g
id fttriple:oai:gotriple.eu:50|dedup_wf_001::a49021b1941794980683f9bf7bfbc04a
record_format openpolar
spelling fttriple:oai:gotriple.eu:50|dedup_wf_001::a49021b1941794980683f9bf7bfbc04a 2023-05-15T15:51:22+02:00 Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions Mariano, Abigail D. Kowaleski, Michael P. Boudrieau, Randy J. 2017-08-03 https://doi.org/10.5061/dryad.5f71g en eng Dryad http://dx.doi.org/10.5061/dryad.5f71g https://dx.doi.org/10.5061/dryad.5f71g lic_creative-commons 10.5061/dryad.5f71g oai:services.nod.dans.knaw.nl:Products/dans:oai:easy.dans.knaw.nl:easy-dataset:94224 oai:easy.dans.knaw.nl:easy-dataset:94224 10|openaire____::9e3be59865b2c1c335d32dae2fe7b254 10|re3data_____::94816e6421eeb072e7742ce6a9decc5f re3data_____::r3d100000044 10|eurocrisdris::fe4903425d9040f680d8610d9079ea14 10|re3data_____::84e123776089ce3c7a33db98d9cd15a8 10|openaire____::081b82f96300b6a6e3d282bad31cb6e2 Canis lupus familiaris saw guide TPLO Jig pin 2005-2007 TPLO osteotomy position 2013-2015 Life sciences medicine and health care info socio Dataset https://vocabularies.coar-repositories.org/resource_types/c_ddb1/ 2017 fttriple https://doi.org/10.5061/dryad.5f71g 2023-01-22T17:13:46Z Objectives: To evaluate the ability of an alignment jig/saw guide to reproduce appropriate osteotomy positions in the tibial plateau leveling osteotomy (TPLO) in the dog. Methods: Lateral radiographs of 65 clinical TPLO procedures using an alignment jig and freehand osteotomy performed by experienced TPLO surgeons using a 24 mm radial saw blade between Dec 2005 - Dec 2007 and Nov 2013 - Nov 2015 were reviewed. The freehand osteotomy position was compared to potential osteotomy positions using the alignment jig/saw guide. The proximal and distal jig pin holes on postoperative radiographs were used to align the jig to the bone; saw guide position was selected to most closely match the osteotomy performed. The guide-to-osteotomy fit was categorized by the distance between the actual osteotomy and proposed saw guide osteotomy at its greatest offset (?1 mm = excellent; ?2 mm = good; ?3 mm = satisfactory; >3 mm = poor). Results: Sixty-four of 65 TPLO osteotomies could be matched satisfactorily by the saw guide. Proximal jig pin placement 3-4 mm from the joint surface and location in a craniocaudal plane on the proximal tibia was significantly associated with the guide-to-osteotomy fit (P = 0.021 and P = 0.047, respectively). Clinical significance: The alignment jig/saw guide can be used to reproduce appropriate freehand osteotomy position for TPLO. Furthermore, an ideal osteotomy position centered on the tibial intercondylar tubercles also is possible. Accurate placement of the proximal jig pin is a crucial step for correct positioning of the saw guide in either instance. PLOSONEcomplete data set. (TPLO alignment jig-saw guide)Raw data collected for two groups of clinically performed TPLOs (a crescent osteotomy of the proximal tibia designed to alter the craniotibial shear force as a result of a cranial cruciate deficient knee). Group 1 (2005-2007): freehand osteotomies with jig only; Group 2 (2013-2015): freehand osteotomies with jig only. Group 1 follows recommendation at that time to place proximal jig pin ... Dataset Canis lupus Unknown
institution Open Polar
collection Unknown
op_collection_id fttriple
language English
topic Canis lupus familiaris
saw guide
TPLO
Jig pin
2005-2007
TPLO osteotomy position
2013-2015
Life sciences
medicine and health care
info
socio
spellingShingle Canis lupus familiaris
saw guide
TPLO
Jig pin
2005-2007
TPLO osteotomy position
2013-2015
Life sciences
medicine and health care
info
socio
Mariano, Abigail D.
Kowaleski, Michael P.
Boudrieau, Randy J.
Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions
topic_facet Canis lupus familiaris
saw guide
TPLO
Jig pin
2005-2007
TPLO osteotomy position
2013-2015
Life sciences
medicine and health care
info
socio
description Objectives: To evaluate the ability of an alignment jig/saw guide to reproduce appropriate osteotomy positions in the tibial plateau leveling osteotomy (TPLO) in the dog. Methods: Lateral radiographs of 65 clinical TPLO procedures using an alignment jig and freehand osteotomy performed by experienced TPLO surgeons using a 24 mm radial saw blade between Dec 2005 - Dec 2007 and Nov 2013 - Nov 2015 were reviewed. The freehand osteotomy position was compared to potential osteotomy positions using the alignment jig/saw guide. The proximal and distal jig pin holes on postoperative radiographs were used to align the jig to the bone; saw guide position was selected to most closely match the osteotomy performed. The guide-to-osteotomy fit was categorized by the distance between the actual osteotomy and proposed saw guide osteotomy at its greatest offset (?1 mm = excellent; ?2 mm = good; ?3 mm = satisfactory; >3 mm = poor). Results: Sixty-four of 65 TPLO osteotomies could be matched satisfactorily by the saw guide. Proximal jig pin placement 3-4 mm from the joint surface and location in a craniocaudal plane on the proximal tibia was significantly associated with the guide-to-osteotomy fit (P = 0.021 and P = 0.047, respectively). Clinical significance: The alignment jig/saw guide can be used to reproduce appropriate freehand osteotomy position for TPLO. Furthermore, an ideal osteotomy position centered on the tibial intercondylar tubercles also is possible. Accurate placement of the proximal jig pin is a crucial step for correct positioning of the saw guide in either instance. PLOSONEcomplete data set. (TPLO alignment jig-saw guide)Raw data collected for two groups of clinically performed TPLOs (a crescent osteotomy of the proximal tibia designed to alter the craniotibial shear force as a result of a cranial cruciate deficient knee). Group 1 (2005-2007): freehand osteotomies with jig only; Group 2 (2013-2015): freehand osteotomies with jig only. Group 1 follows recommendation at that time to place proximal jig pin ...
format Dataset
author Mariano, Abigail D.
Kowaleski, Michael P.
Boudrieau, Randy J.
author_facet Mariano, Abigail D.
Kowaleski, Michael P.
Boudrieau, Randy J.
author_sort Mariano, Abigail D.
title Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions
title_short Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions
title_full Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions
title_fullStr Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions
title_full_unstemmed Data from: Novel TPLO alignment jig/saw guide reproduces freehand and ideal osteotomy positions
title_sort data from: novel tplo alignment jig/saw guide reproduces freehand and ideal osteotomy positions
publisher Dryad
publishDate 2017
url https://doi.org/10.5061/dryad.5f71g
genre Canis lupus
genre_facet Canis lupus
op_source 10.5061/dryad.5f71g
oai:services.nod.dans.knaw.nl:Products/dans:oai:easy.dans.knaw.nl:easy-dataset:94224
oai:easy.dans.knaw.nl:easy-dataset:94224
10|openaire____::9e3be59865b2c1c335d32dae2fe7b254
10|re3data_____::94816e6421eeb072e7742ce6a9decc5f
re3data_____::r3d100000044
10|eurocrisdris::fe4903425d9040f680d8610d9079ea14
10|re3data_____::84e123776089ce3c7a33db98d9cd15a8
10|openaire____::081b82f96300b6a6e3d282bad31cb6e2
op_relation http://dx.doi.org/10.5061/dryad.5f71g
https://dx.doi.org/10.5061/dryad.5f71g
op_rights lic_creative-commons
op_doi https://doi.org/10.5061/dryad.5f71g
_version_ 1766386544091856896