Estimation of professional risk from the factor “lectric field of industrial frequency”

The article presents the results of calculation of the professional risk value from the factor “electric field of industrial frequency” for the personnel of the Central (formerly the Khanty-Mansiysk) Main Power Transmission Line Company (PMES). This calculation was performed using the logical-probab...

Full description

Bibliographic Details
Main Author: Окраинская, И. С.
Other Authors: South Ural State University, Южно-Уральский государственный университет
Format: Article in Journal/Newspaper
Language:Russian
Published: South Ural State University 2014
Subjects:
Online Access:https://vestnik.susu.ru/power/article/view/559
id ftsusunivojs:oai:ojs.vestnik.susu.ac.ru:article/559
record_format openpolar
spelling ftsusunivojs:oai:ojs.vestnik.susu.ac.ru:article/559 2023-05-15T17:02:56+02:00 Estimation of professional risk from the factor “lectric field of industrial frequency” Оценка профессионального риска по фактору «электрическое поле промышленной частоты» Окраинская, И. С. South Ural State University Южно-Уральский государственный университет 2014-11-13 application/pdf https://vestnik.susu.ru/power/article/view/559 rus rus South Ural State University Южно-Уральский государственный университет https://vestnik.susu.ru/power/article/view/559/524 https://vestnik.susu.ru/power/article/view/559 Power Engineering; Том 13, № 2 (2013); 32-35 Энергетика; Том 13, № 2 (2013); 32-35 2409-1057 1990-8512 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion 2014 ftsusunivojs 2020-11-15T16:15:10Z The article presents the results of calculation of the professional risk value from the factor “electric field of industrial frequency” for the personnel of the Central (formerly the Khanty-Mansiysk) Main Power Transmission Line Company (PMES). This calculation was performed using the logical-probability model. The probability of certain events of this model were determined based on data derived from experimental studies of the electric field distribution on the open distribution 500 kV substations, of the company mentioned earlier. Special coefficients have been used to account the harmful effects for human present in areas of varying electric field. Special coefficients have been determined on the basis of the curve of maximum allowable time spent in the electric field of industrial frequency. The author points out the factors that determine the professional risk to personnel operating extra high voltage electrical equipment.Keywords: professional risk, electric field, open distributive substation 500 kV, personnel. В статье приведены результаты расчета величины профессионального риска по фактору «электрическое поле промышленной частоты» для персонала Центрального (ранее Ханты-Мансийского) предприятия магистральных электрических сетей. Расчет выполнен на основе логико-вероятностной модели вероятности повреждения здоровья работников. Вероятности некоторых событий логико-вероятностной модели были определены на основе данных, полученных в результате экспериментального исследования распределения напряженности электрического поля на открытых распределительных устройствах подстанций напряжением 500 кВ, указанного предприятия. Для учета вреда, наносимого пребыванием в зонах различной напряженности электрического поля, были использованы специальные коэффициенты, определенные на основе кривой предельно допустимого времени нахождения в электрическом поле промышленной частоты. Сделаны выводы о факторах, определяющих величину профессионального риска для персонала, обслуживающего электроустановки сверхвысокого напряжения.Ключевые слова: профессиональный риск, электрическое поле, открытое распределительное устройство 500 кВ, обслуживающий персонал. Article in Journal/Newspaper khanty Bulletin of the South Ural State University
institution Open Polar
collection Bulletin of the South Ural State University
op_collection_id ftsusunivojs
language Russian
description The article presents the results of calculation of the professional risk value from the factor “electric field of industrial frequency” for the personnel of the Central (formerly the Khanty-Mansiysk) Main Power Transmission Line Company (PMES). This calculation was performed using the logical-probability model. The probability of certain events of this model were determined based on data derived from experimental studies of the electric field distribution on the open distribution 500 kV substations, of the company mentioned earlier. Special coefficients have been used to account the harmful effects for human present in areas of varying electric field. Special coefficients have been determined on the basis of the curve of maximum allowable time spent in the electric field of industrial frequency. The author points out the factors that determine the professional risk to personnel operating extra high voltage electrical equipment.Keywords: professional risk, electric field, open distributive substation 500 kV, personnel. В статье приведены результаты расчета величины профессионального риска по фактору «электрическое поле промышленной частоты» для персонала Центрального (ранее Ханты-Мансийского) предприятия магистральных электрических сетей. Расчет выполнен на основе логико-вероятностной модели вероятности повреждения здоровья работников. Вероятности некоторых событий логико-вероятностной модели были определены на основе данных, полученных в результате экспериментального исследования распределения напряженности электрического поля на открытых распределительных устройствах подстанций напряжением 500 кВ, указанного предприятия. Для учета вреда, наносимого пребыванием в зонах различной напряженности электрического поля, были использованы специальные коэффициенты, определенные на основе кривой предельно допустимого времени нахождения в электрическом поле промышленной частоты. Сделаны выводы о факторах, определяющих величину профессионального риска для персонала, обслуживающего электроустановки сверхвысокого напряжения.Ключевые слова: профессиональный риск, электрическое поле, открытое распределительное устройство 500 кВ, обслуживающий персонал.
author2 South Ural State University
Южно-Уральский государственный университет
format Article in Journal/Newspaper
author Окраинская, И. С.
spellingShingle Окраинская, И. С.
Estimation of professional risk from the factor “lectric field of industrial frequency”
author_facet Окраинская, И. С.
author_sort Окраинская, И. С.
title Estimation of professional risk from the factor “lectric field of industrial frequency”
title_short Estimation of professional risk from the factor “lectric field of industrial frequency”
title_full Estimation of professional risk from the factor “lectric field of industrial frequency”
title_fullStr Estimation of professional risk from the factor “lectric field of industrial frequency”
title_full_unstemmed Estimation of professional risk from the factor “lectric field of industrial frequency”
title_sort estimation of professional risk from the factor “lectric field of industrial frequency”
publisher South Ural State University
publishDate 2014
url https://vestnik.susu.ru/power/article/view/559
genre khanty
genre_facet khanty
op_source Power Engineering; Том 13, № 2 (2013); 32-35
Энергетика; Том 13, № 2 (2013); 32-35
2409-1057
1990-8512
op_relation https://vestnik.susu.ru/power/article/view/559/524
https://vestnik.susu.ru/power/article/view/559
_version_ 1766056637916774400