Validation of a new method to assess respiratory effort non-invasively

Study Objectives: To compare esophageal pressure (Pes) manometry as a measurement of respiratory effort with two, novel signals derived from calibrated respiratory inductive plethysmography (cRIP). Design: Cross-sectional study. Setting: Landspitali - The National University Hospital of Iceland. Par...

Full description

Bibliographic Details
Main Author: Marta Serwatko 1989-
Other Authors: Háskólinn í Reykjavík
Format: Thesis
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/1946/23804
id ftskemman:oai:skemman.is:1946/23804
record_format openpolar
spelling ftskemman:oai:skemman.is:1946/23804 2023-05-15T16:52:51+02:00 Validation of a new method to assess respiratory effort non-invasively Ný aðferðarfræði til mats á öndunarerfiði í svefni Marta Serwatko 1989- Háskólinn í Reykjavík 2016-01 application/pdf http://hdl.handle.net/1946/23804 en eng http://hdl.handle.net/1946/23804 Heilbrigðisverkfræði Meistaraprófsritgerðir Svefn Öndun Tækni- og verkfræðideild Biomedical engineering Respiration Sleep School of Science and Engineering Thesis Master's 2016 ftskemman 2022-12-11T06:54:21Z Study Objectives: To compare esophageal pressure (Pes) manometry as a measurement of respiratory effort with two, novel signals derived from calibrated respiratory inductive plethysmography (cRIP). Design: Cross-sectional study. Setting: Landspitali - The National University Hospital of Iceland. Participants: 31 subjects (18 males and 13 females, mean ± standard deviation; body mass index 29.9 ± 5.4 kg/m2 , age 47.1 ± 12.9 years, apnea-hypopnea index = 9.3 ± 9.6 per hour). Measurements and Results: Respiratory effort was assessed simultaneously with Pes manometry and cRIP. It is assumed that the breathing movement from the cRIP can be divided into two components, i.e. breathing component and a non-breathing component. Hence, two novel signals were derived from cRIP belts, i.e. cRIP-1 and cRIP-2. These are thought by the authors to reflect two parameters, the former the respiratory drive, and the latter the respiratory effort. Scored events in the cRIP signals were compared with scored events in the Pes signal. Furthermore, it was investigated if cRIP-1, cRIP-2, or Pes events preceded arousals. The sensitivity and positive predictive value (PPV) of scoring respiratory effort (RE) events manually using Pes compared to cRIP-2 was 0.50 and 0.43, respectively. Significant difference was found in the sensitivity of Pes followed by cRIP-1 in sleep stage N1, between N2 and REM (p<0.001). Also, between cRIP-1, N1 and N3 (p=0.001). The correlation coefficient between the number of RE events per patient determined by Pes measurement and cRIP-1 and cRIP-2 was 0.66 and 0.34, respectively. The correlation coefficient between the number of arousals determined by Pes compared with cRIP-1 and cRIP-2 was 0.88 and 0.44, respectively. Conclusions: cRIP-1 and cRIP-2 are important addition and may be very useful in choosing the right treatment option for patients. The cRIP-1 is better in predicting RERA, thus might serve as an alternative to the highly invasive Pes method. Markmið verkefnis: Samanburður tveggja mæliaðferða til ... Thesis Iceland Skemman (Iceland)
institution Open Polar
collection Skemman (Iceland)
op_collection_id ftskemman
language English
topic Heilbrigðisverkfræði
Meistaraprófsritgerðir
Svefn
Öndun
Tækni- og verkfræðideild
Biomedical engineering
Respiration
Sleep
School of Science and Engineering
spellingShingle Heilbrigðisverkfræði
Meistaraprófsritgerðir
Svefn
Öndun
Tækni- og verkfræðideild
Biomedical engineering
Respiration
Sleep
School of Science and Engineering
Marta Serwatko 1989-
Validation of a new method to assess respiratory effort non-invasively
topic_facet Heilbrigðisverkfræði
Meistaraprófsritgerðir
Svefn
Öndun
Tækni- og verkfræðideild
Biomedical engineering
Respiration
Sleep
School of Science and Engineering
description Study Objectives: To compare esophageal pressure (Pes) manometry as a measurement of respiratory effort with two, novel signals derived from calibrated respiratory inductive plethysmography (cRIP). Design: Cross-sectional study. Setting: Landspitali - The National University Hospital of Iceland. Participants: 31 subjects (18 males and 13 females, mean ± standard deviation; body mass index 29.9 ± 5.4 kg/m2 , age 47.1 ± 12.9 years, apnea-hypopnea index = 9.3 ± 9.6 per hour). Measurements and Results: Respiratory effort was assessed simultaneously with Pes manometry and cRIP. It is assumed that the breathing movement from the cRIP can be divided into two components, i.e. breathing component and a non-breathing component. Hence, two novel signals were derived from cRIP belts, i.e. cRIP-1 and cRIP-2. These are thought by the authors to reflect two parameters, the former the respiratory drive, and the latter the respiratory effort. Scored events in the cRIP signals were compared with scored events in the Pes signal. Furthermore, it was investigated if cRIP-1, cRIP-2, or Pes events preceded arousals. The sensitivity and positive predictive value (PPV) of scoring respiratory effort (RE) events manually using Pes compared to cRIP-2 was 0.50 and 0.43, respectively. Significant difference was found in the sensitivity of Pes followed by cRIP-1 in sleep stage N1, between N2 and REM (p<0.001). Also, between cRIP-1, N1 and N3 (p=0.001). The correlation coefficient between the number of RE events per patient determined by Pes measurement and cRIP-1 and cRIP-2 was 0.66 and 0.34, respectively. The correlation coefficient between the number of arousals determined by Pes compared with cRIP-1 and cRIP-2 was 0.88 and 0.44, respectively. Conclusions: cRIP-1 and cRIP-2 are important addition and may be very useful in choosing the right treatment option for patients. The cRIP-1 is better in predicting RERA, thus might serve as an alternative to the highly invasive Pes method. Markmið verkefnis: Samanburður tveggja mæliaðferða til ...
author2 Háskólinn í Reykjavík
format Thesis
author Marta Serwatko 1989-
author_facet Marta Serwatko 1989-
author_sort Marta Serwatko 1989-
title Validation of a new method to assess respiratory effort non-invasively
title_short Validation of a new method to assess respiratory effort non-invasively
title_full Validation of a new method to assess respiratory effort non-invasively
title_fullStr Validation of a new method to assess respiratory effort non-invasively
title_full_unstemmed Validation of a new method to assess respiratory effort non-invasively
title_sort validation of a new method to assess respiratory effort non-invasively
publishDate 2016
url http://hdl.handle.net/1946/23804
genre Iceland
genre_facet Iceland
op_relation http://hdl.handle.net/1946/23804
_version_ 1766043292043051008