Gait, cost and time implications for changing from PTB to ICEX® sockets

The ICEX® system (Ossur, Iceland), allows a socket to be manufactured directly onto the stump and is thought to provide improved comfort due to better pressure distribution whilst being easier to fit and manufacture. The aims of this project were to a) compare gait performance by measuring several g...

Full description

Bibliographic Details
Published in:Prosthetics & Orthotics International
Main Authors: Datta, D., Harris, I., Heller, B., Howitt, J., Martin, R.
Format: Article in Journal/Newspaper
Language:unknown
Published: 2004
Subjects:
Online Access:https://doi.org/10.1080/03093640408726696
id ftsheffhu:oai:shura.shu.ac.uk:2164
record_format openpolar
spelling ftsheffhu:oai:shura.shu.ac.uk:2164 2023-05-15T16:52:13+02:00 Gait, cost and time implications for changing from PTB to ICEX® sockets Datta, D. Harris, I. Heller, B. Howitt, J. Martin, R. 2004 https://doi.org/10.1080/03093640408726696 unknown http://shura.shu.ac.uk/2164/ 10.1080/03093640408726696 DATTA, D., HARRIS, I., HELLER, B. , HOWITT, J. and MARTIN, R. (2004). Gait, cost and time implications for changing from PTB to ICEX® sockets. Prosthetics and orthotics international, 28 (2), 115-120. doi:10.1080/03093640408726696 Article PeerReviewed 2004 ftsheffhu https://doi.org/10.1080/03093640408726696 2023-03-26T20:20:44Z The ICEX® system (Ossur, Iceland), allows a socket to be manufactured directly onto the stump and is thought to provide improved comfort due to better pressure distribution whilst being easier to fit and manufacture. The aims of this project were to a) compare gait performance by measuring several gait characteristics, b) compare production and fitting times, c) investigate financial implications and d) attempt to gauge the amputees' subjective opinions of socket comfort. A randomised, controlled trial was conducted on 27 trans-tibial amputees with an existing patellar tendon bearing (PTB) socket on the Endolite™ system (Chas A. Blatchford, UK). Twenty one (21) subjects completed the study. Of these, 10 in the control group received new PTB sockets while 11 in the experimental group received ICEX®. Gait analysis wearing existing sockets was performed and kinetic data obtained from a force plate. This was repeated with the new sockets after a 6 week period of adjustment. Mann-Whitney tests were used in statistical evaluations with a significance level of 5%. Subjects were asked to score their prosthesis for comfort using the Socket Comfort Score (Hanspal et al., 2003) and the frequency of visits for socket adjustments over a three-month period post-delivery of the sockets was recorded. This study demonstrates no significant difference in any of the gait parameters measured. Though the time required to manufacture a PTB prosthesis was found to be considerably longer than the ICEX®, the overall cost for producing the ICEX® was significantly greater. Subjects showed only minor comfort preference for the ICEX® design and there was no significant difference in the mean number of visits for socket adjustments. In view of the considerable additional cost of providing ICEX® and the lack of evidence of improvement in any parameter tested, the routine provision of ICEX® prostheses to unselected trans-tibial amputees cannot be recommended. Article in Journal/Newspaper Iceland SHURA (Sheffield Hallam University Research Archive) Stump ENVELOPE(-153.167,-153.167,-86.183,-86.183) The Stump ENVELOPE(-58.161,-58.161,-62.097,-62.097) Prosthetics & Orthotics International 28 2 115 120
institution Open Polar
collection SHURA (Sheffield Hallam University Research Archive)
op_collection_id ftsheffhu
language unknown
description The ICEX® system (Ossur, Iceland), allows a socket to be manufactured directly onto the stump and is thought to provide improved comfort due to better pressure distribution whilst being easier to fit and manufacture. The aims of this project were to a) compare gait performance by measuring several gait characteristics, b) compare production and fitting times, c) investigate financial implications and d) attempt to gauge the amputees' subjective opinions of socket comfort. A randomised, controlled trial was conducted on 27 trans-tibial amputees with an existing patellar tendon bearing (PTB) socket on the Endolite™ system (Chas A. Blatchford, UK). Twenty one (21) subjects completed the study. Of these, 10 in the control group received new PTB sockets while 11 in the experimental group received ICEX®. Gait analysis wearing existing sockets was performed and kinetic data obtained from a force plate. This was repeated with the new sockets after a 6 week period of adjustment. Mann-Whitney tests were used in statistical evaluations with a significance level of 5%. Subjects were asked to score their prosthesis for comfort using the Socket Comfort Score (Hanspal et al., 2003) and the frequency of visits for socket adjustments over a three-month period post-delivery of the sockets was recorded. This study demonstrates no significant difference in any of the gait parameters measured. Though the time required to manufacture a PTB prosthesis was found to be considerably longer than the ICEX®, the overall cost for producing the ICEX® was significantly greater. Subjects showed only minor comfort preference for the ICEX® design and there was no significant difference in the mean number of visits for socket adjustments. In view of the considerable additional cost of providing ICEX® and the lack of evidence of improvement in any parameter tested, the routine provision of ICEX® prostheses to unselected trans-tibial amputees cannot be recommended.
format Article in Journal/Newspaper
author Datta, D.
Harris, I.
Heller, B.
Howitt, J.
Martin, R.
spellingShingle Datta, D.
Harris, I.
Heller, B.
Howitt, J.
Martin, R.
Gait, cost and time implications for changing from PTB to ICEX® sockets
author_facet Datta, D.
Harris, I.
Heller, B.
Howitt, J.
Martin, R.
author_sort Datta, D.
title Gait, cost and time implications for changing from PTB to ICEX® sockets
title_short Gait, cost and time implications for changing from PTB to ICEX® sockets
title_full Gait, cost and time implications for changing from PTB to ICEX® sockets
title_fullStr Gait, cost and time implications for changing from PTB to ICEX® sockets
title_full_unstemmed Gait, cost and time implications for changing from PTB to ICEX® sockets
title_sort gait, cost and time implications for changing from ptb to icex® sockets
publishDate 2004
url https://doi.org/10.1080/03093640408726696
long_lat ENVELOPE(-153.167,-153.167,-86.183,-86.183)
ENVELOPE(-58.161,-58.161,-62.097,-62.097)
geographic Stump
The Stump
geographic_facet Stump
The Stump
genre Iceland
genre_facet Iceland
op_relation http://shura.shu.ac.uk/2164/
10.1080/03093640408726696
DATTA, D., HARRIS, I., HELLER, B. , HOWITT, J. and MARTIN, R. (2004). Gait, cost and time implications for changing from PTB to ICEX® sockets. Prosthetics and orthotics international, 28 (2), 115-120.
doi:10.1080/03093640408726696
op_doi https://doi.org/10.1080/03093640408726696
container_title Prosthetics & Orthotics International
container_volume 28
container_issue 2
container_start_page 115
op_container_end_page 120
_version_ 1766042373592186880