Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland

Wind energy harnessing is a new energy production alternative in Iceland. Current installed wind power in Iceland sums to 1.8 MW, which in contrast is 0.1% of the country’s total electricity production. This article is dedicated to the exploration of the potential cost of wind energy production at B...

Full description

Bibliographic Details
Main Authors: Birgir Freyr Ragnarsson, Gudmundur V. Oddsson, Runar Unnthorsson, Birgir Hrafnkelsson
Format: Article in Journal/Newspaper
Language:unknown
Subjects:
Online Access:https://www.mdpi.com/1996-1073/8/9/9464/pdf
https://www.mdpi.com/1996-1073/8/9/9464/
id ftrepec:oai:RePEc:gam:jeners:v:8:y:2015:i:9:p:9464-9485:d:55114
record_format openpolar
spelling ftrepec:oai:RePEc:gam:jeners:v:8:y:2015:i:9:p:9464-9485:d:55114 2024-04-14T08:13:23+00:00 Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland Birgir Freyr Ragnarsson Gudmundur V. Oddsson Runar Unnthorsson Birgir Hrafnkelsson https://www.mdpi.com/1996-1073/8/9/9464/pdf https://www.mdpi.com/1996-1073/8/9/9464/ unknown https://www.mdpi.com/1996-1073/8/9/9464/pdf https://www.mdpi.com/1996-1073/8/9/9464/ article ftrepec 2024-03-19T10:31:24Z Wind energy harnessing is a new energy production alternative in Iceland. Current installed wind power in Iceland sums to 1.8 MW, which in contrast is 0.1% of the country’s total electricity production. This article is dedicated to the exploration of the potential cost of wind energy production at Búrfell in the south of Iceland. A levelized cost of energy (LCOE) approach was applied to the estimation of the potential cost. Weibull simulation is used to simulate wind data for calculations. A confirmation of the power law is done by comparing real data to calculated values. A modified Weibull simulation is verified by comparing results with actual on-site test wind turbines. A wind farm of 99MWis suggested for the site. Key results were the capacity factor (CF) at Búrfell being 38.15% on average and that the LCOE for wind energy was estimated as 0.087–0.088 USD/kWh (assuming 10% weighted average cost of capital (WACC)), which classifies Búrfell among the lowest LCOE sites for wind energy in Europe. wind energy; levelized cost of energy (LCOE); annual energy production (AEP); modified Weibull; Iceland Article in Journal/Newspaper Iceland RePEc (Research Papers in Economics) Búrfell ENVELOPE(-19.818,-19.818,64.079,64.079)
institution Open Polar
collection RePEc (Research Papers in Economics)
op_collection_id ftrepec
language unknown
description Wind energy harnessing is a new energy production alternative in Iceland. Current installed wind power in Iceland sums to 1.8 MW, which in contrast is 0.1% of the country’s total electricity production. This article is dedicated to the exploration of the potential cost of wind energy production at Búrfell in the south of Iceland. A levelized cost of energy (LCOE) approach was applied to the estimation of the potential cost. Weibull simulation is used to simulate wind data for calculations. A confirmation of the power law is done by comparing real data to calculated values. A modified Weibull simulation is verified by comparing results with actual on-site test wind turbines. A wind farm of 99MWis suggested for the site. Key results were the capacity factor (CF) at Búrfell being 38.15% on average and that the LCOE for wind energy was estimated as 0.087–0.088 USD/kWh (assuming 10% weighted average cost of capital (WACC)), which classifies Búrfell among the lowest LCOE sites for wind energy in Europe. wind energy; levelized cost of energy (LCOE); annual energy production (AEP); modified Weibull; Iceland
format Article in Journal/Newspaper
author Birgir Freyr Ragnarsson
Gudmundur V. Oddsson
Runar Unnthorsson
Birgir Hrafnkelsson
spellingShingle Birgir Freyr Ragnarsson
Gudmundur V. Oddsson
Runar Unnthorsson
Birgir Hrafnkelsson
Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland
author_facet Birgir Freyr Ragnarsson
Gudmundur V. Oddsson
Runar Unnthorsson
Birgir Hrafnkelsson
author_sort Birgir Freyr Ragnarsson
title Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland
title_short Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland
title_full Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland
title_fullStr Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland
title_full_unstemmed Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland
title_sort levelized cost of energy analysis of a wind power generation system at búrfell in iceland
url https://www.mdpi.com/1996-1073/8/9/9464/pdf
https://www.mdpi.com/1996-1073/8/9/9464/
long_lat ENVELOPE(-19.818,-19.818,64.079,64.079)
geographic Búrfell
geographic_facet Búrfell
genre Iceland
genre_facet Iceland
op_relation https://www.mdpi.com/1996-1073/8/9/9464/pdf
https://www.mdpi.com/1996-1073/8/9/9464/
_version_ 1796311363935535104