Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo

LOW-COST DATA LOGGERS FOR AIR, SOIL AND ROCK TEMPERATURE MONITORING -Tiny Talk II data loggers were adapted in the laboratory of the Centro de Estudos Geográficos for air, soil and rock temperature monitoring. The loggers are single-channel 8 bit devices with a 2K EEPROM memory that allows the regis...

Full description

Bibliographic Details
Published in:Finisterra
Main Authors: Viera, Gonçalo Teles, Mora, Carla, Ramos, Miguel
Format: Article in Journal/Newspaper
Language:Portuguese
Published: Centro de Estudos Geográficos 2000
Subjects:
Online Access:https://revistas.rcaap.pt/finisterra/article/view/1673
id ftrcaapojs:oai:ojs.revistas.rcaap.pt:article/1673
record_format openpolar
spelling ftrcaapojs:oai:ojs.revistas.rcaap.pt:article/1673 2023-05-15T14:15:49+02:00 Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo Viera, Gonçalo Teles Mora, Carla Ramos, Miguel 2000-01-01 application/pdf https://revistas.rcaap.pt/finisterra/article/view/1673 por por Centro de Estudos Geográficos https://revistas.rcaap.pt/finisterra/article/view/1673/1367 https://revistas.rcaap.pt/finisterra/article/view/1673 Direitos de Autor (c) 2017 Finisterra Finisterra; Vol. 35 Núm. 69 (2000) Finisterra; Vol. 35 N.º 69 (2000) 2182-2905 0430-5027 info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion 2000 ftrcaapojs 2022-07-28T05:58:50Z LOW-COST DATA LOGGERS FOR AIR, SOIL AND ROCK TEMPERATURE MONITORING -Tiny Talk II data loggers were adapted in the laboratory of the Centro de Estudos Geográficos for air, soil and rock temperature monitoring. The loggers are single-channel 8 bit devices with a 2K EEPROM memory that allows the registration of 1,800 temperature records at user-defined intervals. Temperatures are measured by NTC100 thermistors separated by the authors from the data logger for more accurate measurements. Data is transfered from the loggers into a portable computer using a RS-232 cable. It is a low-cost system very appropriate for use in rough environmental conditions, particularly in mountain areas. It is successfully tested by the authors in the Antartic, Pyrenees, Sierra Nevada and Serra da Estrela.The detailed procedures for the construction of three measuring systems are described. The air temperature apparatus is constructed using PVC tubing and protecting cases and is designed for the measurement of air temperatures at 130cm above the ground. The soil temperature monitoring apparatus measures temperatures at 1, 5, 10 and 20cm depth and is based in 4 data loggers protected from moisture and dust in an IP68 case. The rock temperature measuring system is similar to the latter but the sensors are installed in the interior of the rock and isolated using silicon glue. Article in Journal/Newspaper antartic* SARC - Serviço de Alojamento de Revistas Científicas (RCAAP - Repositório Científico de Acesso Aberto de Portugal) Finisterra 35 69
institution Open Polar
collection SARC - Serviço de Alojamento de Revistas Científicas (RCAAP - Repositório Científico de Acesso Aberto de Portugal)
op_collection_id ftrcaapojs
language Portuguese
description LOW-COST DATA LOGGERS FOR AIR, SOIL AND ROCK TEMPERATURE MONITORING -Tiny Talk II data loggers were adapted in the laboratory of the Centro de Estudos Geográficos for air, soil and rock temperature monitoring. The loggers are single-channel 8 bit devices with a 2K EEPROM memory that allows the registration of 1,800 temperature records at user-defined intervals. Temperatures are measured by NTC100 thermistors separated by the authors from the data logger for more accurate measurements. Data is transfered from the loggers into a portable computer using a RS-232 cable. It is a low-cost system very appropriate for use in rough environmental conditions, particularly in mountain areas. It is successfully tested by the authors in the Antartic, Pyrenees, Sierra Nevada and Serra da Estrela.The detailed procedures for the construction of three measuring systems are described. The air temperature apparatus is constructed using PVC tubing and protecting cases and is designed for the measurement of air temperatures at 130cm above the ground. The soil temperature monitoring apparatus measures temperatures at 1, 5, 10 and 20cm depth and is based in 4 data loggers protected from moisture and dust in an IP68 case. The rock temperature measuring system is similar to the latter but the sensors are installed in the interior of the rock and isolated using silicon glue.
format Article in Journal/Newspaper
author Viera, Gonçalo Teles
Mora, Carla
Ramos, Miguel
spellingShingle Viera, Gonçalo Teles
Mora, Carla
Ramos, Miguel
Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo
author_facet Viera, Gonçalo Teles
Mora, Carla
Ramos, Miguel
author_sort Viera, Gonçalo Teles
title Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo
title_short Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo
title_full Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo
title_fullStr Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo
title_full_unstemmed Registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo
title_sort registadores automáticos de baixo-custo para a monitorização de temperaturas do ar, da rocha e do solo
publisher Centro de Estudos Geográficos
publishDate 2000
url https://revistas.rcaap.pt/finisterra/article/view/1673
genre antartic*
genre_facet antartic*
op_source Finisterra; Vol. 35 Núm. 69 (2000)
Finisterra; Vol. 35 N.º 69 (2000)
2182-2905
0430-5027
op_relation https://revistas.rcaap.pt/finisterra/article/view/1673/1367
https://revistas.rcaap.pt/finisterra/article/view/1673
op_rights Direitos de Autor (c) 2017 Finisterra
container_title Finisterra
container_volume 35
container_issue 69
_version_ 1766288095549849600