Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities
The data in this paper are related to the research article entitled “Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components” (Frossard et al. Clinical Biomechanics, 89 (2021) 105457. DOI:10.1016/j.clinbiomech.2021.105457)....
Published in: | Data in Brief |
---|---|
Main Authors: | , , , , |
Format: | Text |
Language: | English |
Published: |
Elsevier
2022
|
Subjects: | |
Online Access: | http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859002/ https://doi.org/10.1016/j.dib.2022.107936 |
id |
ftpubmed:oai:pubmedcentral.nih.gov:8859002 |
---|---|
record_format |
openpolar |
spelling |
ftpubmed:oai:pubmedcentral.nih.gov:8859002 2023-05-15T16:51:40+02:00 Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities Frossard, Laurent Laux, Stefan Geada, Marta Heym, Peter Paul Lechler, Knut 2022-02-10 http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859002/ https://doi.org/10.1016/j.dib.2022.107936 en eng Elsevier http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859002/ http://dx.doi.org/10.1016/j.dib.2022.107936 © 2022 The Author(s). Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). CC-BY Data Brief Data Article Text 2022 ftpubmed https://doi.org/10.1016/j.dib.2022.107936 2022-03-06T01:45:58Z The data in this paper are related to the research article entitled “Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components” (Frossard et al. Clinical Biomechanics, 89 (2021) 105457. DOI:10.1016/j.clinbiomech.2021.105457). This article contains the overall and individual loading characteristics applied on transfemoral press-fit osseointegrated implant generated by bone-anchored prostheses fitted with state-of-the-art components during daily activities (i.e., microprocessor-controlled Rheo Knee XC knee, energy-storing-and-returning Pro-Flex XC or LP feet (ÖSSUR, Iceland)). Confounders of the loads are presented. The load profiles are characterized by the loading patterns, loading boundaries and loading local extrema of the forces and moments applied during straight-level walking, ascending and descending ramp and stairs at self-selected comfortable pace. The confounders of the loading information as well as new insights into inter-participants variability of loading patterns, loading boundaries and loading local extrema can inform the design of subsequent cross-sectional and longitudinal studies as well as literature reviews and meta-analyzes. The loading datasets are critical to clinicians and engineers designing finite element models of osseointegrated implants (e.g., medullar and percutaneous parts) and prosthetic components, algorithms capable to recognize the loading patterns applied on a residuum during daily activities, as well as clinical trials assessing the effects of particular prosthetic care interventions. Altogether, these datasets provide promoters of prosthetic care innovations with valuable insights informing the prescription of advanced prosthetic components to the growing population of individuals suffering from lower limb loss choosing bionics solutions. Online repository contains the files: https://data.mendeley.com/datasets/gmsyv97cpc/1 Text Iceland PubMed Central (PMC) Data in Brief 41 107936 |
institution |
Open Polar |
collection |
PubMed Central (PMC) |
op_collection_id |
ftpubmed |
language |
English |
topic |
Data Article |
spellingShingle |
Data Article Frossard, Laurent Laux, Stefan Geada, Marta Heym, Peter Paul Lechler, Knut Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities |
topic_facet |
Data Article |
description |
The data in this paper are related to the research article entitled “Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components” (Frossard et al. Clinical Biomechanics, 89 (2021) 105457. DOI:10.1016/j.clinbiomech.2021.105457). This article contains the overall and individual loading characteristics applied on transfemoral press-fit osseointegrated implant generated by bone-anchored prostheses fitted with state-of-the-art components during daily activities (i.e., microprocessor-controlled Rheo Knee XC knee, energy-storing-and-returning Pro-Flex XC or LP feet (ÖSSUR, Iceland)). Confounders of the loads are presented. The load profiles are characterized by the loading patterns, loading boundaries and loading local extrema of the forces and moments applied during straight-level walking, ascending and descending ramp and stairs at self-selected comfortable pace. The confounders of the loading information as well as new insights into inter-participants variability of loading patterns, loading boundaries and loading local extrema can inform the design of subsequent cross-sectional and longitudinal studies as well as literature reviews and meta-analyzes. The loading datasets are critical to clinicians and engineers designing finite element models of osseointegrated implants (e.g., medullar and percutaneous parts) and prosthetic components, algorithms capable to recognize the loading patterns applied on a residuum during daily activities, as well as clinical trials assessing the effects of particular prosthetic care interventions. Altogether, these datasets provide promoters of prosthetic care innovations with valuable insights informing the prescription of advanced prosthetic components to the growing population of individuals suffering from lower limb loss choosing bionics solutions. Online repository contains the files: https://data.mendeley.com/datasets/gmsyv97cpc/1 |
format |
Text |
author |
Frossard, Laurent Laux, Stefan Geada, Marta Heym, Peter Paul Lechler, Knut |
author_facet |
Frossard, Laurent Laux, Stefan Geada, Marta Heym, Peter Paul Lechler, Knut |
author_sort |
Frossard, Laurent |
title |
Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities |
title_short |
Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities |
title_full |
Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities |
title_fullStr |
Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities |
title_full_unstemmed |
Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities |
title_sort |
loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art components during daily activities |
publisher |
Elsevier |
publishDate |
2022 |
url |
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859002/ https://doi.org/10.1016/j.dib.2022.107936 |
genre |
Iceland |
genre_facet |
Iceland |
op_source |
Data Brief |
op_relation |
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8859002/ http://dx.doi.org/10.1016/j.dib.2022.107936 |
op_rights |
© 2022 The Author(s). Published by Elsevier Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
op_rightsnorm |
CC-BY |
op_doi |
https://doi.org/10.1016/j.dib.2022.107936 |
container_title |
Data in Brief |
container_volume |
41 |
container_start_page |
107936 |
_version_ |
1766041779247775744 |