Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal

The carbon stable isotope ratio (delta C-13 value) of an environmentally-relevant Toxaphene congener in technical products and a biological sample from a remote region was in the focus of this work. For this reason, the major octachlorobornane residue of the multicomponent pesticide Toxaphene in bio...

Full description

Bibliographic Details
Main Authors: Vetter, W., Schlatterer, J., Gleixner, G.
Format: Article in Journal/Newspaper
Language:unknown
Published: 2006
Subjects:
Online Access:http://hdl.handle.net/11858/00-001M-0000-000E-D4AD-7
http://hdl.handle.net/11858/00-001M-0000-000E-D4AC-9
id ftpubman:oai:pure.mpg.de:item_1692166
record_format openpolar
spelling ftpubman:oai:pure.mpg.de:item_1692166 2023-08-27T04:06:05+02:00 Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal Vetter, W. Schlatterer, J. Gleixner, G. 2006 application/octet-stream http://hdl.handle.net/11858/00-001M-0000-000E-D4AD-7 http://hdl.handle.net/11858/00-001M-0000-000E-D4AC-9 unknown http://hdl.handle.net/11858/00-001M-0000-000E-D4AD-7 http://hdl.handle.net/11858/00-001M-0000-000E-D4AC-9 Journal of Chromatography A info:eu-repo/semantics/article 2006 ftpubman 2023-08-02T01:01:55Z The carbon stable isotope ratio (delta C-13 value) of an environmentally-relevant Toxaphene congener in technical products and a biological sample from a remote region was in the focus of this work. For this reason, the major octachlorobornane residue of the multicomponent pesticide Toxaphene in biological samples, 2-endo,3-exo,5-endo,6-exo,8,8,10,10-octachlorobornane (B8-1413 or P26), was quantitatively enriched from two technical Toxaphene mixtures (Toxaphene and Melipax) in duplicates as well as from an Antarctic Weddell seal sample. Normal phase followed by reversed-phase high-performance liquid chromatography (HPLC) with three columns, respectively, coupled in series was used for this purpose. Four of the five fractionated samples fulfilled the requirement of an interference-free GC-elution for subsequent determination of the delta C-13 value by gas chromatography interfaced to an isotope ratio mass spectrometer (GC-IRMS). B8-1413 in Toxaphene (n = 1) was more depleted in C-12 than in Melipax (n = 2), which agrees with previous results obtained for the entire mixtures. The B8-1413 isolate from a Weddell seal sample from the Antarctic showed a 8 degrees C value between the two technical products. Although a source appointment to the one or the other product was not possible, this example indicates that long range transport to the Antarctic and by uptake and food-chain bioaccumulation of B8-1413 in seals did not change the delta C-13 value significantly. The observed differences in one duplicate sample indicate that statistic evaluation of samples used for isotope ratio MS measurements is an important issue. (c) 2006 Elsevier B.V. All rights reserved. [References: 24] Article in Journal/Newspaper Antarc* Antarctic Weddell Seal Max Planck Society: MPG.PuRe Antarctic The Antarctic Weddell
institution Open Polar
collection Max Planck Society: MPG.PuRe
op_collection_id ftpubman
language unknown
description The carbon stable isotope ratio (delta C-13 value) of an environmentally-relevant Toxaphene congener in technical products and a biological sample from a remote region was in the focus of this work. For this reason, the major octachlorobornane residue of the multicomponent pesticide Toxaphene in biological samples, 2-endo,3-exo,5-endo,6-exo,8,8,10,10-octachlorobornane (B8-1413 or P26), was quantitatively enriched from two technical Toxaphene mixtures (Toxaphene and Melipax) in duplicates as well as from an Antarctic Weddell seal sample. Normal phase followed by reversed-phase high-performance liquid chromatography (HPLC) with three columns, respectively, coupled in series was used for this purpose. Four of the five fractionated samples fulfilled the requirement of an interference-free GC-elution for subsequent determination of the delta C-13 value by gas chromatography interfaced to an isotope ratio mass spectrometer (GC-IRMS). B8-1413 in Toxaphene (n = 1) was more depleted in C-12 than in Melipax (n = 2), which agrees with previous results obtained for the entire mixtures. The B8-1413 isolate from a Weddell seal sample from the Antarctic showed a 8 degrees C value between the two technical products. Although a source appointment to the one or the other product was not possible, this example indicates that long range transport to the Antarctic and by uptake and food-chain bioaccumulation of B8-1413 in seals did not change the delta C-13 value significantly. The observed differences in one duplicate sample indicate that statistic evaluation of samples used for isotope ratio MS measurements is an important issue. (c) 2006 Elsevier B.V. All rights reserved. [References: 24]
format Article in Journal/Newspaper
author Vetter, W.
Schlatterer, J.
Gleixner, G.
spellingShingle Vetter, W.
Schlatterer, J.
Gleixner, G.
Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal
author_facet Vetter, W.
Schlatterer, J.
Gleixner, G.
author_sort Vetter, W.
title Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal
title_short Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal
title_full Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal
title_fullStr Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal
title_full_unstemmed Experiments directed to the compound-specific determination of the stable carbon isotope ratios of the Toxaphene congener B8-1413 in two technical mixtures and Antarctic Weddell seal
title_sort experiments directed to the compound-specific determination of the stable carbon isotope ratios of the toxaphene congener b8-1413 in two technical mixtures and antarctic weddell seal
publishDate 2006
url http://hdl.handle.net/11858/00-001M-0000-000E-D4AD-7
http://hdl.handle.net/11858/00-001M-0000-000E-D4AC-9
geographic Antarctic
The Antarctic
Weddell
geographic_facet Antarctic
The Antarctic
Weddell
genre Antarc*
Antarctic
Weddell Seal
genre_facet Antarc*
Antarctic
Weddell Seal
op_source Journal of Chromatography A
op_relation http://hdl.handle.net/11858/00-001M-0000-000E-D4AD-7
http://hdl.handle.net/11858/00-001M-0000-000E-D4AC-9
_version_ 1775346825708961792