Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)

Noble gases (3He, 4He, 20Ne, 22Ne) The water samples for stable noble gas isotopes (3He, 4He, 20Ne, 22Ne) were stored from the CTD/water bottle system without contact to atmospheric air and preventing air bubbles into gas tight copper tubes, which are clamped of at both sides. In the IUP Bremen nobl...

Full description

Bibliographic Details
Main Authors: Huhn, Oliver, Rhein, Monika, Bulsiewicz, Klaus, Sültenfuß, Jürgen
Format: Dataset
Language:English
Published: PANGAEA 2021
Subjects:
He
Ne
Online Access:https://doi.pangaea.de/10.1594/PANGAEA.930718
https://doi.org/10.1594/PANGAEA.930718
id ftpangaea:oai:pangaea.de:doi:10.1594/PANGAEA.930718
record_format openpolar
institution Open Polar
collection PANGAEA - Data Publisher for Earth & Environmental Science
op_collection_id ftpangaea
language English
topic Antarctica
ANT-XXXIII/2
Bottle number
CFC12
CTD/Rosette
CTD-RO
Date/Time of event
DEPTH
water
Elevation of event
Event label
Freon-12 (dichlorodifluoromethane)
Gas chromatographic (GC) separation on a capillary column
electron capture detection (ECD)
He
Helium
Helium-4
Latitude of event
Lazarev Sea
Longitude of event
Ne
Neon
noblegas
Polarstern
Pressure
PS111
PS111_100-1
PS111_101-1
PS111_10-2
PS111_12-2
PS111_122-1
PS111_123-1
PS111_124-1
PS111_126-1
PS111_127-1
PS111_128-1
PS111_129-1
PS111_130-1
PS111_131-1
PS111_132-1
PS111_133-1
PS111_14-5
PS111_18-1
PS111_19-3
PS111_20-3
PS111_21-3
PS111_22-1
PS111_23-1
PS111_24-1
spellingShingle Antarctica
ANT-XXXIII/2
Bottle number
CFC12
CTD/Rosette
CTD-RO
Date/Time of event
DEPTH
water
Elevation of event
Event label
Freon-12 (dichlorodifluoromethane)
Gas chromatographic (GC) separation on a capillary column
electron capture detection (ECD)
He
Helium
Helium-4
Latitude of event
Lazarev Sea
Longitude of event
Ne
Neon
noblegas
Polarstern
Pressure
PS111
PS111_100-1
PS111_101-1
PS111_10-2
PS111_12-2
PS111_122-1
PS111_123-1
PS111_124-1
PS111_126-1
PS111_127-1
PS111_128-1
PS111_129-1
PS111_130-1
PS111_131-1
PS111_132-1
PS111_133-1
PS111_14-5
PS111_18-1
PS111_19-3
PS111_20-3
PS111_21-3
PS111_22-1
PS111_23-1
PS111_24-1
Huhn, Oliver
Rhein, Monika
Bulsiewicz, Klaus
Sültenfuß, Jürgen
Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
topic_facet Antarctica
ANT-XXXIII/2
Bottle number
CFC12
CTD/Rosette
CTD-RO
Date/Time of event
DEPTH
water
Elevation of event
Event label
Freon-12 (dichlorodifluoromethane)
Gas chromatographic (GC) separation on a capillary column
electron capture detection (ECD)
He
Helium
Helium-4
Latitude of event
Lazarev Sea
Longitude of event
Ne
Neon
noblegas
Polarstern
Pressure
PS111
PS111_100-1
PS111_101-1
PS111_10-2
PS111_12-2
PS111_122-1
PS111_123-1
PS111_124-1
PS111_126-1
PS111_127-1
PS111_128-1
PS111_129-1
PS111_130-1
PS111_131-1
PS111_132-1
PS111_133-1
PS111_14-5
PS111_18-1
PS111_19-3
PS111_20-3
PS111_21-3
PS111_22-1
PS111_23-1
PS111_24-1
description Noble gases (3He, 4He, 20Ne, 22Ne) The water samples for stable noble gas isotopes (3He, 4He, 20Ne, 22Ne) were stored from the CTD/water bottle system without contact to atmospheric air and preventing air bubbles into gas tight copper tubes, which are clamped of at both sides. In the IUP Bremen noble gas lab the samples were pre-processed with a UHV (ultra high vacuum) gas extraction system. Sample gases are transferred via water vapor into a glass ampoule kept at liquid nitrogen temperature. For analysis of the noble gas isotopes the glass ampoules are connected to a fully automated UHV mass spectrometric system equipped with a two stage cryogenic system. Regularly, the system is calibrated with atmospheric air standards (reproducibility <0.2%). Also measurement of line blanks and linearity are done. The performance of the Bremen facility is described in Sültenfuß et al. (2009). The total errors for the noble gas measurements are estimated to be < 0.5 % for 4He, < 0.5 % for total Ne, and < 0.5% for δ3He Transient tracer (CFC-12, SF6) Chlorofluorocarbon (CFC-12) and sulfur hexafluoride (SF6) water samples from the CTD-bottle-system were stored in glass ampoules without contact to the atmosphere during the tapping. Immediately after sampling the ampoules are flame sealed after a CFC free headspace of pure nitrogen had been applied. The determination of concentrations in the IUP Bremen gas chromatography lab is accomplished by purge and trap sample pre-treatment followed by gas chromatographic (GC) separation on a capillary column and electron capture detection (ECD). The system is calibrated by analyzing several different volumes of a known standard gas. The loss of trace gas into the headspace is considered by a careful equilibration between liquid and gas phase under controlled conditions before the sealed ampoules are opened and a precise measurement of the volume of the headspace. Concentrations are calibrated on SIO98 scale (Prinn et al., 2000). A more detailed description of the measurement ...
format Dataset
author Huhn, Oliver
Rhein, Monika
Bulsiewicz, Klaus
Sültenfuß, Jürgen
author_facet Huhn, Oliver
Rhein, Monika
Bulsiewicz, Klaus
Sültenfuß, Jürgen
author_sort Huhn, Oliver
title Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
title_short Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
title_full Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
title_fullStr Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
title_full_unstemmed Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
title_sort noble gas (he, ne isotopes) and transient tracer (cfc-12, sf6) measurements from polarstern cruise ps111 (weddell sea, 2018)
publisher PANGAEA
publishDate 2021
url https://doi.pangaea.de/10.1594/PANGAEA.930718
https://doi.org/10.1594/PANGAEA.930718
op_coverage MEDIAN LATITUDE: -75.656097 * MEDIAN LONGITUDE: -38.031039 * SOUTH-BOUND LATITUDE: -77.898024 * WEST-BOUND LONGITUDE: -61.025867 * NORTH-BOUND LATITUDE: -63.999757 * EAST-BOUND LONGITUDE: 4.999871 * DATE/TIME START: 2018-01-26T09:46:00 * DATE/TIME END: 2018-02-28T03:59:00 * MINIMUM DEPTH, water: 1.8 m * MAXIMUM DEPTH, water: 4558.3 m
long_lat ENVELOPE(12.917,12.917,-69.967,-69.967)
ENVELOPE(7.000,7.000,-68.000,-68.000)
ENVELOPE(-61.025867,4.999871,-63.999757,-77.898024)
geographic Weddell Sea
Weddell
Lazarev
Lazarev Sea
geographic_facet Weddell Sea
Weddell
Lazarev
Lazarev Sea
genre Antarc*
Antarctica
Berichte zur Polar- und Meeresforschung
Lazarev Sea
Reports on Polar and Marine Research
Weddell Sea
genre_facet Antarc*
Antarctica
Berichte zur Polar- und Meeresforschung
Lazarev Sea
Reports on Polar and Marine Research
Weddell Sea
op_relation Janout, Markus A; Hellmer, Hartmut H; Hattermann, Tore; Huhn, Oliver; Sültenfuß, Jürgen; Østerhus, Svein; Stulic, Lukrecia; Ryan, Svenja; Schröder, Michael; Kanzow, Torsten (2021): FRIS Revisited in 2018: On the Circulation and Water Masses at the Filchner and Ronne Ice Shelves in the Southern Weddell Sea. Journal of Geophysical Research: Oceans, 126(6), https://doi.org/10.1029/2021JC017269
Janout, Markus A; Hellmer, Hartmut H; Schröder, Michael; Wisotzki, Andreas (2019): Physical oceanography measured on water bottle samples during POLARSTERN cruise PS111 (ANT-XXXIII/2) [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.897283
Schröder, Michael (2018): The Expedition PS111 of the Research Vessel POLARSTERN to the southern Weddell Sea in 2018. Berichte zur Polar- und Meeresforschung = Reports on Polar and Marine Research, 718, 161 pp, https://doi.org/10.2312/BzPM_0718_2018
Readme: Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018). https://download.pangaea.de/reference/108141/attachments/ps111_CFC12_SF6_He_d3He_Ne_ohuhn_IUP_bremen_germany_readme.pdf
Bulsiewicz, Klaus; Rose, Henning; Klatt, Olaf; Putzka, Alfred; Roether, Wolfgang (1998): A capillary-column chromatographic system for efficient chlorofluorocarbon measurement in ocean waters. Journal of Geophysical Research, 103(C8), 15959-15970, https://doi.org/10.1029/98JC00140
Prinn, Ronald G M; Weiss, Ray F; Fraser, Paul J B; Simmonds, Peter; Cunnold, Derek M; Alyea, F N; O'Doherty, Simon; Salameh, P K; Miller, B R; Huang, J; Wang, R H J; Hartley, D E; Harth, C; Steele, L P; Sturrock, G; Midgley, P M; McCulloch, A (2000): A history of chemically and radiatively important gases in air deduced from ALE/GAGE/AGAGE. Journal of Geophysical Research: Atmospheres, 105(D14), 17751-17792, https://doi.org/10.1029/2000JD900141
Sültenfuß, Jürgen; Roether, Wolfgang; Rhein, Monika (2009): The Bremen mass spectrometric facility for the measurement of helium isotopes, neon, and tritium in water. Isotopes in Environmental and Health Studies, 45(2), 83-95, https://doi.org/10.1080/10256010902871929
https://doi.pangaea.de/10.1594/PANGAEA.930718
https://doi.org/10.1594/PANGAEA.930718
op_rights CC-BY-4.0: Creative Commons Attribution 4.0 International
Access constraints: unrestricted
info:eu-repo/semantics/openAccess
op_doi https://doi.org/10.1594/PANGAEA.93071810.1029/2021JC01726910.1594/PANGAEA.89728310.2312/BzPM_0718_201810.1029/98JC0014010.1029/2000JD90014110.1080/10256010902871929
_version_ 1812177344919502848
spelling ftpangaea:oai:pangaea.de:doi:10.1594/PANGAEA.930718 2024-10-06T13:42:49+00:00 Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018) Huhn, Oliver Rhein, Monika Bulsiewicz, Klaus Sültenfuß, Jürgen MEDIAN LATITUDE: -75.656097 * MEDIAN LONGITUDE: -38.031039 * SOUTH-BOUND LATITUDE: -77.898024 * WEST-BOUND LONGITUDE: -61.025867 * NORTH-BOUND LATITUDE: -63.999757 * EAST-BOUND LONGITUDE: 4.999871 * DATE/TIME START: 2018-01-26T09:46:00 * DATE/TIME END: 2018-02-28T03:59:00 * MINIMUM DEPTH, water: 1.8 m * MAXIMUM DEPTH, water: 4558.3 m 2021 text/tab-separated-values, 4928 data points https://doi.pangaea.de/10.1594/PANGAEA.930718 https://doi.org/10.1594/PANGAEA.930718 en eng PANGAEA Janout, Markus A; Hellmer, Hartmut H; Hattermann, Tore; Huhn, Oliver; Sültenfuß, Jürgen; Østerhus, Svein; Stulic, Lukrecia; Ryan, Svenja; Schröder, Michael; Kanzow, Torsten (2021): FRIS Revisited in 2018: On the Circulation and Water Masses at the Filchner and Ronne Ice Shelves in the Southern Weddell Sea. Journal of Geophysical Research: Oceans, 126(6), https://doi.org/10.1029/2021JC017269 Janout, Markus A; Hellmer, Hartmut H; Schröder, Michael; Wisotzki, Andreas (2019): Physical oceanography measured on water bottle samples during POLARSTERN cruise PS111 (ANT-XXXIII/2) [dataset]. Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research, Bremerhaven, PANGAEA, https://doi.org/10.1594/PANGAEA.897283 Schröder, Michael (2018): The Expedition PS111 of the Research Vessel POLARSTERN to the southern Weddell Sea in 2018. Berichte zur Polar- und Meeresforschung = Reports on Polar and Marine Research, 718, 161 pp, https://doi.org/10.2312/BzPM_0718_2018 Readme: Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018). https://download.pangaea.de/reference/108141/attachments/ps111_CFC12_SF6_He_d3He_Ne_ohuhn_IUP_bremen_germany_readme.pdf Bulsiewicz, Klaus; Rose, Henning; Klatt, Olaf; Putzka, Alfred; Roether, Wolfgang (1998): A capillary-column chromatographic system for efficient chlorofluorocarbon measurement in ocean waters. Journal of Geophysical Research, 103(C8), 15959-15970, https://doi.org/10.1029/98JC00140 Prinn, Ronald G M; Weiss, Ray F; Fraser, Paul J B; Simmonds, Peter; Cunnold, Derek M; Alyea, F N; O'Doherty, Simon; Salameh, P K; Miller, B R; Huang, J; Wang, R H J; Hartley, D E; Harth, C; Steele, L P; Sturrock, G; Midgley, P M; McCulloch, A (2000): A history of chemically and radiatively important gases in air deduced from ALE/GAGE/AGAGE. Journal of Geophysical Research: Atmospheres, 105(D14), 17751-17792, https://doi.org/10.1029/2000JD900141 Sültenfuß, Jürgen; Roether, Wolfgang; Rhein, Monika (2009): The Bremen mass spectrometric facility for the measurement of helium isotopes, neon, and tritium in water. Isotopes in Environmental and Health Studies, 45(2), 83-95, https://doi.org/10.1080/10256010902871929 https://doi.pangaea.de/10.1594/PANGAEA.930718 https://doi.org/10.1594/PANGAEA.930718 CC-BY-4.0: Creative Commons Attribution 4.0 International Access constraints: unrestricted info:eu-repo/semantics/openAccess Antarctica ANT-XXXIII/2 Bottle number CFC12 CTD/Rosette CTD-RO Date/Time of event DEPTH water Elevation of event Event label Freon-12 (dichlorodifluoromethane) Gas chromatographic (GC) separation on a capillary column electron capture detection (ECD) He Helium Helium-4 Latitude of event Lazarev Sea Longitude of event Ne Neon noblegas Polarstern Pressure PS111 PS111_100-1 PS111_101-1 PS111_10-2 PS111_12-2 PS111_122-1 PS111_123-1 PS111_124-1 PS111_126-1 PS111_127-1 PS111_128-1 PS111_129-1 PS111_130-1 PS111_131-1 PS111_132-1 PS111_133-1 PS111_14-5 PS111_18-1 PS111_19-3 PS111_20-3 PS111_21-3 PS111_22-1 PS111_23-1 PS111_24-1 dataset 2021 ftpangaea https://doi.org/10.1594/PANGAEA.93071810.1029/2021JC01726910.1594/PANGAEA.89728310.2312/BzPM_0718_201810.1029/98JC0014010.1029/2000JD90014110.1080/10256010902871929 2024-09-11T00:15:18Z Noble gases (3He, 4He, 20Ne, 22Ne) The water samples for stable noble gas isotopes (3He, 4He, 20Ne, 22Ne) were stored from the CTD/water bottle system without contact to atmospheric air and preventing air bubbles into gas tight copper tubes, which are clamped of at both sides. In the IUP Bremen noble gas lab the samples were pre-processed with a UHV (ultra high vacuum) gas extraction system. Sample gases are transferred via water vapor into a glass ampoule kept at liquid nitrogen temperature. For analysis of the noble gas isotopes the glass ampoules are connected to a fully automated UHV mass spectrometric system equipped with a two stage cryogenic system. Regularly, the system is calibrated with atmospheric air standards (reproducibility <0.2%). Also measurement of line blanks and linearity are done. The performance of the Bremen facility is described in Sültenfuß et al. (2009). The total errors for the noble gas measurements are estimated to be < 0.5 % for 4He, < 0.5 % for total Ne, and < 0.5% for δ3He Transient tracer (CFC-12, SF6) Chlorofluorocarbon (CFC-12) and sulfur hexafluoride (SF6) water samples from the CTD-bottle-system were stored in glass ampoules without contact to the atmosphere during the tapping. Immediately after sampling the ampoules are flame sealed after a CFC free headspace of pure nitrogen had been applied. The determination of concentrations in the IUP Bremen gas chromatography lab is accomplished by purge and trap sample pre-treatment followed by gas chromatographic (GC) separation on a capillary column and electron capture detection (ECD). The system is calibrated by analyzing several different volumes of a known standard gas. The loss of trace gas into the headspace is considered by a careful equilibration between liquid and gas phase under controlled conditions before the sealed ampoules are opened and a precise measurement of the volume of the headspace. Concentrations are calibrated on SIO98 scale (Prinn et al., 2000). A more detailed description of the measurement ... Dataset Antarc* Antarctica Berichte zur Polar- und Meeresforschung Lazarev Sea Reports on Polar and Marine Research Weddell Sea PANGAEA - Data Publisher for Earth & Environmental Science Weddell Sea Weddell Lazarev ENVELOPE(12.917,12.917,-69.967,-69.967) Lazarev Sea ENVELOPE(7.000,7.000,-68.000,-68.000) ENVELOPE(-61.025867,4.999871,-63.999757,-77.898024)