CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016

Water samples for CFC and SF6 measurements were collected using a CTD/rosette sampling system. The CFC/SF6 sample was the first sample drawn from the rosette bottle. The samples were collected in 250 cc glass stoppered bottles through a PVC tube connected to the rosette bottle drain valve. Bubbles w...

Full description

Bibliographic Details
Main Author: Smethie, William M jr
Format: Dataset
Language:English
Published: PANGAEA 2017
Subjects:
Online Access:https://doi.pangaea.de/10.1594/PANGAEA.872956
https://doi.org/10.1594/PANGAEA.872956
id ftpangaea:oai:pangaea.de:doi:10.1594/PANGAEA.872956
record_format openpolar
institution Open Polar
collection PANGAEA - Data Publisher for Earth & Environmental Science
op_collection_id ftpangaea
language English
topic Arctic Ocean
ARK-XXIX/3
Barents Sea
Bottle number
CTD/Rosette
CTD-RO
Date/Time of event
DEPTH
water
Elevation of event
Event label
Freon-11 (trichorofluoromethane)
Freon-113
Freon-12 (dichlorodifluoromethane)
GEOTRACES
Global marine biogeochemical cycles of trace elements and their isotopes
Latitude of event
Longitude of event
Polarstern
Pressure
PS94
PS94/004-1
PS94/018-3
PS94/032-2
PS94/040-1
PS94/040-3
PS94/046-4
PS94/050-1
PS94/050-4
PS94/050-6
PS94/054-2
PS94/058-1
PS94/058-3
PS94/058-5
PS94/062-1
PS94/064-1
PS94/068-1
PS94/069-4
PS94/069-5
PS94/072-1
PS94/074-1
PS94/076-1
PS94/080-1
PS94/081-2
PS94/081-5
PS94/081-7
PS94/085-1
PS94/089-1
PS94/096-2
spellingShingle Arctic Ocean
ARK-XXIX/3
Barents Sea
Bottle number
CTD/Rosette
CTD-RO
Date/Time of event
DEPTH
water
Elevation of event
Event label
Freon-11 (trichorofluoromethane)
Freon-113
Freon-12 (dichlorodifluoromethane)
GEOTRACES
Global marine biogeochemical cycles of trace elements and their isotopes
Latitude of event
Longitude of event
Polarstern
Pressure
PS94
PS94/004-1
PS94/018-3
PS94/032-2
PS94/040-1
PS94/040-3
PS94/046-4
PS94/050-1
PS94/050-4
PS94/050-6
PS94/054-2
PS94/058-1
PS94/058-3
PS94/058-5
PS94/062-1
PS94/064-1
PS94/068-1
PS94/069-4
PS94/069-5
PS94/072-1
PS94/074-1
PS94/076-1
PS94/080-1
PS94/081-2
PS94/081-5
PS94/081-7
PS94/085-1
PS94/089-1
PS94/096-2
Smethie, William M jr
CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016
topic_facet Arctic Ocean
ARK-XXIX/3
Barents Sea
Bottle number
CTD/Rosette
CTD-RO
Date/Time of event
DEPTH
water
Elevation of event
Event label
Freon-11 (trichorofluoromethane)
Freon-113
Freon-12 (dichlorodifluoromethane)
GEOTRACES
Global marine biogeochemical cycles of trace elements and their isotopes
Latitude of event
Longitude of event
Polarstern
Pressure
PS94
PS94/004-1
PS94/018-3
PS94/032-2
PS94/040-1
PS94/040-3
PS94/046-4
PS94/050-1
PS94/050-4
PS94/050-6
PS94/054-2
PS94/058-1
PS94/058-3
PS94/058-5
PS94/062-1
PS94/064-1
PS94/068-1
PS94/069-4
PS94/069-5
PS94/072-1
PS94/074-1
PS94/076-1
PS94/080-1
PS94/081-2
PS94/081-5
PS94/081-7
PS94/085-1
PS94/089-1
PS94/096-2
description Water samples for CFC and SF6 measurements were collected using a CTD/rosette sampling system. The CFC/SF6 sample was the first sample drawn from the rosette bottle. The samples were collected in 250 cc glass stoppered bottles through a PVC tube connected to the rosette bottle drain valve. Bubbles were cleared from the tube with water flowing and the tube was inserted to the bottom of the 250 cc glass bottle. The glass bottle was placed in a wide mouth plastic jar that extended above the opening of the glass bottle. The overflow water collected in the jar, filling and overflowing the jar and covering the glass bottle opening. The flow continued for 3 overflow volumes of the glass bottle (750 cc) and the glass stopper was then inserted underwater preventing air from being trapped in the sample. The bottle was then placed upside down in the jar, the jar was capped and the sample stored at 2°C in a refrigerator to prevent degassing. At the end of the cruise, the samples were packed in insulated boxes with cold packs to maintain the 2°C temperature and shipped by air freight to Lamont-Doherty Earth Observatory. The measurements were carried out at Lamont using a dual purge and trap system interfaced to a dual ECD (electron capture detector) HP6890 gas chromatograph. When a water sample is introduced into the system, it is split into two aliquots, a 20 cc aliquot for CFC measurement and a 180 cc aliquot for SF6 measurement. The aliquots are transferred to appropriately sized sparging chambers and stripped with ultra high purity nitrogen, which transports the extracted gases to cold traps (Unibeads-2s for CFCs, Carboxan-1000 for SF6) cooled to -80°C. The traps are then heated to 110°C for CFCs and 165°C for SF6 and flushed into the gas chromatograph where CFCs are separated with a Porasil-B pre-column and a Carbograph 1AC main column and SF6 is separated with a pre-column and main column of Molecular Sieve 5A. The gases are detected by the ECDs. The ECDs are calibrated by running gas standards with known ...
format Dataset
author Smethie, William M jr
author_facet Smethie, William M jr
author_sort Smethie, William M jr
title CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016
title_short CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016
title_full CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016
title_fullStr CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016
title_full_unstemmed CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016
title_sort cfc-11, cfc-12, cfc-113, and sf6 measured on water bottle samples during polarstern cruise ps94 (ark-xxix/3) to the arctic ocean in 2016
publisher PANGAEA
publishDate 2017
url https://doi.pangaea.de/10.1594/PANGAEA.872956
https://doi.org/10.1594/PANGAEA.872956
op_coverage MEDIAN LATITUDE: 86.161035 * MEDIAN LONGITUDE: 81.955273 * SOUTH-BOUND LATITUDE: 79.251170 * WEST-BOUND LONGITUDE: 29.664170 * NORTH-BOUND LATITUDE: 89.649170 * EAST-BOUND LONGITUDE: -119.457670 * DATE/TIME START: 2015-08-20T00:45:00 * DATE/TIME END: 2015-09-14T16:15:00 * MINIMUM DEPTH, water: 1.3 m * MAXIMUM DEPTH, water: 4849.6 m
long_lat ENVELOPE(29.664170,-119.457670,89.649170,79.251170)
genre Arctic
Arctic Ocean
Barents Sea
Berichte zur Polar- und Meeresforschung
Reports on Polar and Marine Research
genre_facet Arctic
Arctic Ocean
Barents Sea
Berichte zur Polar- und Meeresforschung
Reports on Polar and Marine Research
op_source Lamont-Doherty Earth Observatory of Columbia University, New York
op_relation Schauer, Ursula (2016): The Expedition PS94 of the Research Vessel POLARSTERN to the central Arctic Ocean in 2015. Berichte zur Polar- und Meeresforschung = Reports on Polar and Marine Research, 703, 170 pp, https://doi.org/10.2312/BzPM_0703_2016
https://doi.pangaea.de/10.1594/PANGAEA.872956
https://doi.org/10.1594/PANGAEA.872956
op_rights CC-BY-SA-3.0: Creative Commons Attribution-ShareAlike 3.0 Unported
Access constraints: unrestricted
info:eu-repo/semantics/openAccess
op_doi https://doi.org/10.1594/PANGAEA.87295610.2312/BzPM_0703_2016
_version_ 1810292722504826880
spelling ftpangaea:oai:pangaea.de:doi:10.1594/PANGAEA.872956 2024-09-15T17:50:55+00:00 CFC-11, CFC-12, CFC-113, and SF6 measured on water bottle samples during POLARSTERN cruise PS94 (ARK-XXIX/3) to the Arctic Ocean in 2016 Smethie, William M jr MEDIAN LATITUDE: 86.161035 * MEDIAN LONGITUDE: 81.955273 * SOUTH-BOUND LATITUDE: 79.251170 * WEST-BOUND LONGITUDE: 29.664170 * NORTH-BOUND LATITUDE: 89.649170 * EAST-BOUND LONGITUDE: -119.457670 * DATE/TIME START: 2015-08-20T00:45:00 * DATE/TIME END: 2015-09-14T16:15:00 * MINIMUM DEPTH, water: 1.3 m * MAXIMUM DEPTH, water: 4849.6 m 2017 text/tab-separated-values, 3228 data points https://doi.pangaea.de/10.1594/PANGAEA.872956 https://doi.org/10.1594/PANGAEA.872956 en eng PANGAEA Schauer, Ursula (2016): The Expedition PS94 of the Research Vessel POLARSTERN to the central Arctic Ocean in 2015. Berichte zur Polar- und Meeresforschung = Reports on Polar and Marine Research, 703, 170 pp, https://doi.org/10.2312/BzPM_0703_2016 https://doi.pangaea.de/10.1594/PANGAEA.872956 https://doi.org/10.1594/PANGAEA.872956 CC-BY-SA-3.0: Creative Commons Attribution-ShareAlike 3.0 Unported Access constraints: unrestricted info:eu-repo/semantics/openAccess Lamont-Doherty Earth Observatory of Columbia University, New York Arctic Ocean ARK-XXIX/3 Barents Sea Bottle number CTD/Rosette CTD-RO Date/Time of event DEPTH water Elevation of event Event label Freon-11 (trichorofluoromethane) Freon-113 Freon-12 (dichlorodifluoromethane) GEOTRACES Global marine biogeochemical cycles of trace elements and their isotopes Latitude of event Longitude of event Polarstern Pressure PS94 PS94/004-1 PS94/018-3 PS94/032-2 PS94/040-1 PS94/040-3 PS94/046-4 PS94/050-1 PS94/050-4 PS94/050-6 PS94/054-2 PS94/058-1 PS94/058-3 PS94/058-5 PS94/062-1 PS94/064-1 PS94/068-1 PS94/069-4 PS94/069-5 PS94/072-1 PS94/074-1 PS94/076-1 PS94/080-1 PS94/081-2 PS94/081-5 PS94/081-7 PS94/085-1 PS94/089-1 PS94/096-2 dataset 2017 ftpangaea https://doi.org/10.1594/PANGAEA.87295610.2312/BzPM_0703_2016 2024-07-24T02:31:33Z Water samples for CFC and SF6 measurements were collected using a CTD/rosette sampling system. The CFC/SF6 sample was the first sample drawn from the rosette bottle. The samples were collected in 250 cc glass stoppered bottles through a PVC tube connected to the rosette bottle drain valve. Bubbles were cleared from the tube with water flowing and the tube was inserted to the bottom of the 250 cc glass bottle. The glass bottle was placed in a wide mouth plastic jar that extended above the opening of the glass bottle. The overflow water collected in the jar, filling and overflowing the jar and covering the glass bottle opening. The flow continued for 3 overflow volumes of the glass bottle (750 cc) and the glass stopper was then inserted underwater preventing air from being trapped in the sample. The bottle was then placed upside down in the jar, the jar was capped and the sample stored at 2°C in a refrigerator to prevent degassing. At the end of the cruise, the samples were packed in insulated boxes with cold packs to maintain the 2°C temperature and shipped by air freight to Lamont-Doherty Earth Observatory. The measurements were carried out at Lamont using a dual purge and trap system interfaced to a dual ECD (electron capture detector) HP6890 gas chromatograph. When a water sample is introduced into the system, it is split into two aliquots, a 20 cc aliquot for CFC measurement and a 180 cc aliquot for SF6 measurement. The aliquots are transferred to appropriately sized sparging chambers and stripped with ultra high purity nitrogen, which transports the extracted gases to cold traps (Unibeads-2s for CFCs, Carboxan-1000 for SF6) cooled to -80°C. The traps are then heated to 110°C for CFCs and 165°C for SF6 and flushed into the gas chromatograph where CFCs are separated with a Porasil-B pre-column and a Carbograph 1AC main column and SF6 is separated with a pre-column and main column of Molecular Sieve 5A. The gases are detected by the ECDs. The ECDs are calibrated by running gas standards with known ... Dataset Arctic Arctic Ocean Barents Sea Berichte zur Polar- und Meeresforschung Reports on Polar and Marine Research PANGAEA - Data Publisher for Earth & Environmental Science ENVELOPE(29.664170,-119.457670,89.649170,79.251170)