Daystar Corporation installed a solar/electric domestic water heating system in the Borda Wing of the South County Hospital, Wakefield, R.I. in 1975. Initial performance measurements showed that the overall water heating system efficiency was approximately 35 percent. To deliver one unit of hot wate...
Main Authors: | , , |
---|---|
Language: | unknown |
Published: |
2020
|
Subjects: | |
Online Access: | http://www.osti.gov/servlets/purl/6940833 https://www.osti.gov/biblio/6940833 https://doi.org/10.2172/6940833 |
id |
ftosti:oai:osti.gov:6940833 |
---|---|
record_format |
openpolar |
spelling |
ftosti:oai:osti.gov:6940833 2023-07-30T04:05:24+02:00 Hot water system efficiency study at South County Hospital, Wakefield, Rhode Island Cummings, R.D. Peck, D.J. Hall, W.J. 2020-05-18 application/pdf http://www.osti.gov/servlets/purl/6940833 https://www.osti.gov/biblio/6940833 https://doi.org/10.2172/6940833 unknown http://www.osti.gov/servlets/purl/6940833 https://www.osti.gov/biblio/6940833 https://doi.org/10.2172/6940833 doi:10.2172/6940833 14 SOLAR ENERGY HOSPITALS SOLAR WATER HEATING SOLAR WATER HEATERS EFFICIENCY BOILERS ELECTRIC APPLIANCES ENERGY CONSERVATION FLAT PLATE COLLECTORS HEAT LOSSES PERFORMANCE TESTING PIPES RHODE ISLAND WATER APPLIANCES BUILDINGS ENERGY LOSSES GAS APPLIANCES HEATERS HEATING HYDROGEN COMPOUNDS MEDICAL CENTERS NORTH ATLANTIC REGION OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR HEATING TESTING WATER HEATERS 2020 ftosti https://doi.org/10.2172/6940833 2023-07-11T10:52:58Z Daystar Corporation installed a solar/electric domestic water heating system in the Borda Wing of the South County Hospital, Wakefield, R.I. in 1975. Initial performance measurements showed that the overall water heating system efficiency was approximately 35 percent. To deliver one unit of hot water ''at the faucet'' required three units of energy input. This study was undertaken to identify the losses which caused this low efficiency and possible improvements which could be made at the South County installation and in future similar installations. Other/Unknown Material North Atlantic SciTec Connect (Office of Scientific and Technical Information - OSTI, U.S. Department of Energy) Wakefield ENVELOPE(-65.183,-65.183,-69.283,-69.283) |
institution |
Open Polar |
collection |
SciTec Connect (Office of Scientific and Technical Information - OSTI, U.S. Department of Energy) |
op_collection_id |
ftosti |
language |
unknown |
topic |
14 SOLAR ENERGY HOSPITALS SOLAR WATER HEATING SOLAR WATER HEATERS EFFICIENCY BOILERS ELECTRIC APPLIANCES ENERGY CONSERVATION FLAT PLATE COLLECTORS HEAT LOSSES PERFORMANCE TESTING PIPES RHODE ISLAND WATER APPLIANCES BUILDINGS ENERGY LOSSES GAS APPLIANCES HEATERS HEATING HYDROGEN COMPOUNDS MEDICAL CENTERS NORTH ATLANTIC REGION OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR HEATING TESTING WATER HEATERS |
spellingShingle |
14 SOLAR ENERGY HOSPITALS SOLAR WATER HEATING SOLAR WATER HEATERS EFFICIENCY BOILERS ELECTRIC APPLIANCES ENERGY CONSERVATION FLAT PLATE COLLECTORS HEAT LOSSES PERFORMANCE TESTING PIPES RHODE ISLAND WATER APPLIANCES BUILDINGS ENERGY LOSSES GAS APPLIANCES HEATERS HEATING HYDROGEN COMPOUNDS MEDICAL CENTERS NORTH ATLANTIC REGION OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR HEATING TESTING WATER HEATERS Cummings, R.D. Peck, D.J. Hall, W.J. Hot water system efficiency study at South County Hospital, Wakefield, Rhode Island |
topic_facet |
14 SOLAR ENERGY HOSPITALS SOLAR WATER HEATING SOLAR WATER HEATERS EFFICIENCY BOILERS ELECTRIC APPLIANCES ENERGY CONSERVATION FLAT PLATE COLLECTORS HEAT LOSSES PERFORMANCE TESTING PIPES RHODE ISLAND WATER APPLIANCES BUILDINGS ENERGY LOSSES GAS APPLIANCES HEATERS HEATING HYDROGEN COMPOUNDS MEDICAL CENTERS NORTH ATLANTIC REGION OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR HEATING TESTING WATER HEATERS |
description |
Daystar Corporation installed a solar/electric domestic water heating system in the Borda Wing of the South County Hospital, Wakefield, R.I. in 1975. Initial performance measurements showed that the overall water heating system efficiency was approximately 35 percent. To deliver one unit of hot water ''at the faucet'' required three units of energy input. This study was undertaken to identify the losses which caused this low efficiency and possible improvements which could be made at the South County installation and in future similar installations. |
author |
Cummings, R.D. Peck, D.J. Hall, W.J. |
author_facet |
Cummings, R.D. Peck, D.J. Hall, W.J. |
author_sort |
Cummings, R.D. |
title |
Hot water system efficiency study at South County Hospital, Wakefield, Rhode Island |
title_short |
Hot water system efficiency study at South County Hospital, Wakefield, Rhode Island |
title_full |
Hot water system efficiency study at South County Hospital, Wakefield, Rhode Island |
title_fullStr |
Hot water system efficiency study at South County Hospital, Wakefield, Rhode Island |
title_full_unstemmed |
Hot water system efficiency study at South County Hospital, Wakefield, Rhode Island |
title_sort |
hot water system efficiency study at south county hospital, wakefield, rhode island |
publishDate |
2020 |
url |
http://www.osti.gov/servlets/purl/6940833 https://www.osti.gov/biblio/6940833 https://doi.org/10.2172/6940833 |
long_lat |
ENVELOPE(-65.183,-65.183,-69.283,-69.283) |
geographic |
Wakefield |
geographic_facet |
Wakefield |
genre |
North Atlantic |
genre_facet |
North Atlantic |
op_relation |
http://www.osti.gov/servlets/purl/6940833 https://www.osti.gov/biblio/6940833 https://doi.org/10.2172/6940833 doi:10.2172/6940833 |
op_doi |
https://doi.org/10.2172/6940833 |
_version_ |
1772817262556741632 |