Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers

Thermal performance predictions based on test data are presented for the Custom Engineering trough and Sandia-designed receivers, with glass reflector surface, for three output temperatures at five cities in the United States. Two experimental receivers were tested, one with an antireflective coatin...

Full description

Bibliographic Details
Main Author: Harrison, T.D.
Language:unknown
Published: 2020
Subjects:
USA
Online Access:http://www.osti.gov/servlets/purl/6564485
https://www.osti.gov/biblio/6564485
https://doi.org/10.2172/6564485
id ftosti:oai:osti.gov:6564485
record_format openpolar
spelling ftosti:oai:osti.gov:6564485 2023-07-30T04:05:22+02:00 Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers Harrison, T.D. 2020-08-21 application/pdf http://www.osti.gov/servlets/purl/6564485 https://www.osti.gov/biblio/6564485 https://doi.org/10.2172/6564485 unknown http://www.osti.gov/servlets/purl/6564485 https://www.osti.gov/biblio/6564485 https://doi.org/10.2172/6564485 doi:10.2172/6564485 14 SOLAR ENERGY PARABOLIC TROUGH COLLECTORS PERFORMANCE TESTING ANTIREFLECTION COATINGS CALIFORNIA COMPUTER CALCULATIONS EFFICIENCY EXPERIMENTAL DATA MASSACHUSETTS MSSTF NEW MEXICO PERFORMANCE SOUTH CAROLINA TEXAS THEORETICAL DATA COATINGS CONCENTRATING COLLECTORS DATA EQUIPMENT INFORMATION NORTH AMERICA NORTH ATLANTIC REGION NUMERICAL DATA PARABOLIC COLLECTORS SOLAR COLLECTORS SOLAR EQUIPMENT SOUTHEAST REGION SOUTHWEST REGION TEST FACILITIES TESTING USA WESTERN REGION 2020 ftosti https://doi.org/10.2172/6564485 2023-07-11T10:49:42Z Thermal performance predictions based on test data are presented for the Custom Engineering trough and Sandia-designed receivers, with glass reflector surface, for three output temperatures at five cities in the United States. Two experimental receivers were tested, one with an antireflective coating on the glass envelope around the receiver tube and one without the antireflective coating. Other/Unknown Material North Atlantic SciTec Connect (Office of Scientific and Technical Information - OSTI, U.S. Department of Energy)
institution Open Polar
collection SciTec Connect (Office of Scientific and Technical Information - OSTI, U.S. Department of Energy)
op_collection_id ftosti
language unknown
topic 14 SOLAR ENERGY
PARABOLIC TROUGH COLLECTORS
PERFORMANCE TESTING
ANTIREFLECTION COATINGS
CALIFORNIA
COMPUTER CALCULATIONS
EFFICIENCY
EXPERIMENTAL DATA
MASSACHUSETTS
MSSTF
NEW MEXICO
PERFORMANCE
SOUTH CAROLINA
TEXAS
THEORETICAL DATA
COATINGS
CONCENTRATING COLLECTORS
DATA
EQUIPMENT
INFORMATION
NORTH AMERICA
NORTH ATLANTIC REGION
NUMERICAL DATA
PARABOLIC COLLECTORS
SOLAR COLLECTORS
SOLAR EQUIPMENT
SOUTHEAST REGION
SOUTHWEST REGION
TEST FACILITIES
TESTING
USA
WESTERN REGION
spellingShingle 14 SOLAR ENERGY
PARABOLIC TROUGH COLLECTORS
PERFORMANCE TESTING
ANTIREFLECTION COATINGS
CALIFORNIA
COMPUTER CALCULATIONS
EFFICIENCY
EXPERIMENTAL DATA
MASSACHUSETTS
MSSTF
NEW MEXICO
PERFORMANCE
SOUTH CAROLINA
TEXAS
THEORETICAL DATA
COATINGS
CONCENTRATING COLLECTORS
DATA
EQUIPMENT
INFORMATION
NORTH AMERICA
NORTH ATLANTIC REGION
NUMERICAL DATA
PARABOLIC COLLECTORS
SOLAR COLLECTORS
SOLAR EQUIPMENT
SOUTHEAST REGION
SOUTHWEST REGION
TEST FACILITIES
TESTING
USA
WESTERN REGION
Harrison, T.D.
Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers
topic_facet 14 SOLAR ENERGY
PARABOLIC TROUGH COLLECTORS
PERFORMANCE TESTING
ANTIREFLECTION COATINGS
CALIFORNIA
COMPUTER CALCULATIONS
EFFICIENCY
EXPERIMENTAL DATA
MASSACHUSETTS
MSSTF
NEW MEXICO
PERFORMANCE
SOUTH CAROLINA
TEXAS
THEORETICAL DATA
COATINGS
CONCENTRATING COLLECTORS
DATA
EQUIPMENT
INFORMATION
NORTH AMERICA
NORTH ATLANTIC REGION
NUMERICAL DATA
PARABOLIC COLLECTORS
SOLAR COLLECTORS
SOLAR EQUIPMENT
SOUTHEAST REGION
SOUTHWEST REGION
TEST FACILITIES
TESTING
USA
WESTERN REGION
description Thermal performance predictions based on test data are presented for the Custom Engineering trough and Sandia-designed receivers, with glass reflector surface, for three output temperatures at five cities in the United States. Two experimental receivers were tested, one with an antireflective coating on the glass envelope around the receiver tube and one without the antireflective coating.
author Harrison, T.D.
author_facet Harrison, T.D.
author_sort Harrison, T.D.
title Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers
title_short Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers
title_full Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers
title_fullStr Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers
title_full_unstemmed Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers
title_sort midtemperature solar systems test facility predictions for thermal performance based on test data: custom engineering trough with glass reflector surface and sandia-designed receivers
publishDate 2020
url http://www.osti.gov/servlets/purl/6564485
https://www.osti.gov/biblio/6564485
https://doi.org/10.2172/6564485
genre North Atlantic
genre_facet North Atlantic
op_relation http://www.osti.gov/servlets/purl/6564485
https://www.osti.gov/biblio/6564485
https://doi.org/10.2172/6564485
doi:10.2172/6564485
op_doi https://doi.org/10.2172/6564485
_version_ 1772817232998432768