Midtemperature Solar Systems Test Facility predictions for thermal performance based on test data: Custom Engineering trough with glass reflector surface and Sandia-designed receivers
Thermal performance predictions based on test data are presented for the Custom Engineering trough and Sandia-designed receivers, with glass reflector surface, for three output temperatures at five cities in the United States. Two experimental receivers were tested, one with an antireflective coatin...
Main Author: | |
---|---|
Language: | unknown |
Published: |
2020
|
Subjects: | |
Online Access: | http://www.osti.gov/servlets/purl/6564485 https://www.osti.gov/biblio/6564485 https://doi.org/10.2172/6564485 |
Summary: | Thermal performance predictions based on test data are presented for the Custom Engineering trough and Sandia-designed receivers, with glass reflector surface, for three output temperatures at five cities in the United States. Two experimental receivers were tested, one with an antireflective coating on the glass envelope around the receiver tube and one without the antireflective coating. |
---|