Solar heating system installed at Stamford, CT. Final report
Information is provided on the solar heating system installed at the Lutz-Sotire Partnership Executive East Office Building, Stamford, Connecticut. The information consists of description of system and components, operation and maintenance manual, as-built drawings and manufacturer's compon...
Main Author: | |
---|---|
Language: | unknown |
Published: |
2013
|
Subjects: | |
Online Access: | http://www.osti.gov/servlets/purl/5275949 https://www.osti.gov/biblio/5275949 https://doi.org/10.2172/5275949 |
id |
ftosti:oai:osti.gov:5275949 |
---|---|
record_format |
openpolar |
spelling |
ftosti:oai:osti.gov:5275949 2023-07-30T04:05:29+02:00 Solar heating system installed at Stamford, CT. Final report Not Available 2013-04-12 application/pdf http://www.osti.gov/servlets/purl/5275949 https://www.osti.gov/biblio/5275949 https://doi.org/10.2172/5275949 unknown http://www.osti.gov/servlets/purl/5275949 https://www.osti.gov/biblio/5275949 https://doi.org/10.2172/5275949 doi:10.2172/5275949 14 SOLAR ENERGY OFFICE BUILDINGS SOLAR SPACE HEATING SOLAR HEATING SYSTEMS OPERATION ANTIFREEZE CONNECTICUT DESIGN FLAT PLATE COLLECTORS FREEZE PROTECTION GLYCOLS MAINTENANCE SENSIBLE HEAT STORAGE TANKS WATER ALCOHOLS BUILDINGS CONTAINERS ENERGY STORAGE EQUIPMENT HEAT STORAGE HEATING HEATING SYSTEMS HYDROGEN COMPOUNDS HYDROXY COMPOUNDS NORTH AMERICA NORTH ATLANTIC REGION ORGANIC COMPOUNDS OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR EQUIPMENT SOLAR HEATING SPACE HEATING STORAGE USA 2013 ftosti https://doi.org/10.2172/5275949 2023-07-11T10:38:19Z Information is provided on the solar heating system installed at the Lutz-Sotire Partnership Executive East Office Building, Stamford, Connecticut. The information consists of description of system and components, operation and maintenance manual, as-built drawings and manufacturer's component data. The solar system was designed to provide approximately 50 percent of the heating requirements. The solar facility has 2,561 sq. ft. of liquid flat plate collectors and a 6000 gallon, stone lined, well-insulated storage tank. Freeze protection is provided by a 50 percent glycol/water mixture in the collector loop. From the storage tank, solar heated water is fed into the building's distributed heat pump loop via a modulating three-way valve. If the storage tank temperature drops below 80/sup 0/F, the building loop may be supplied from the existing electrical hot water boilers. The Executive East Office Building is of moderate size, 25,000 sq. ft. of heated space in 2 1/2 stories. The solar system makes available for other users up to 150 KVA of existing electrical generating capacity. Other/Unknown Material North Atlantic SciTec Connect (Office of Scientific and Technical Information - OSTI, U.S. Department of Energy) |
institution |
Open Polar |
collection |
SciTec Connect (Office of Scientific and Technical Information - OSTI, U.S. Department of Energy) |
op_collection_id |
ftosti |
language |
unknown |
topic |
14 SOLAR ENERGY OFFICE BUILDINGS SOLAR SPACE HEATING SOLAR HEATING SYSTEMS OPERATION ANTIFREEZE CONNECTICUT DESIGN FLAT PLATE COLLECTORS FREEZE PROTECTION GLYCOLS MAINTENANCE SENSIBLE HEAT STORAGE TANKS WATER ALCOHOLS BUILDINGS CONTAINERS ENERGY STORAGE EQUIPMENT HEAT STORAGE HEATING HEATING SYSTEMS HYDROGEN COMPOUNDS HYDROXY COMPOUNDS NORTH AMERICA NORTH ATLANTIC REGION ORGANIC COMPOUNDS OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR EQUIPMENT SOLAR HEATING SPACE HEATING STORAGE USA |
spellingShingle |
14 SOLAR ENERGY OFFICE BUILDINGS SOLAR SPACE HEATING SOLAR HEATING SYSTEMS OPERATION ANTIFREEZE CONNECTICUT DESIGN FLAT PLATE COLLECTORS FREEZE PROTECTION GLYCOLS MAINTENANCE SENSIBLE HEAT STORAGE TANKS WATER ALCOHOLS BUILDINGS CONTAINERS ENERGY STORAGE EQUIPMENT HEAT STORAGE HEATING HEATING SYSTEMS HYDROGEN COMPOUNDS HYDROXY COMPOUNDS NORTH AMERICA NORTH ATLANTIC REGION ORGANIC COMPOUNDS OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR EQUIPMENT SOLAR HEATING SPACE HEATING STORAGE USA Not Available Solar heating system installed at Stamford, CT. Final report |
topic_facet |
14 SOLAR ENERGY OFFICE BUILDINGS SOLAR SPACE HEATING SOLAR HEATING SYSTEMS OPERATION ANTIFREEZE CONNECTICUT DESIGN FLAT PLATE COLLECTORS FREEZE PROTECTION GLYCOLS MAINTENANCE SENSIBLE HEAT STORAGE TANKS WATER ALCOHOLS BUILDINGS CONTAINERS ENERGY STORAGE EQUIPMENT HEAT STORAGE HEATING HEATING SYSTEMS HYDROGEN COMPOUNDS HYDROXY COMPOUNDS NORTH AMERICA NORTH ATLANTIC REGION ORGANIC COMPOUNDS OXYGEN COMPOUNDS SOLAR COLLECTORS SOLAR EQUIPMENT SOLAR HEATING SPACE HEATING STORAGE USA |
description |
Information is provided on the solar heating system installed at the Lutz-Sotire Partnership Executive East Office Building, Stamford, Connecticut. The information consists of description of system and components, operation and maintenance manual, as-built drawings and manufacturer's component data. The solar system was designed to provide approximately 50 percent of the heating requirements. The solar facility has 2,561 sq. ft. of liquid flat plate collectors and a 6000 gallon, stone lined, well-insulated storage tank. Freeze protection is provided by a 50 percent glycol/water mixture in the collector loop. From the storage tank, solar heated water is fed into the building's distributed heat pump loop via a modulating three-way valve. If the storage tank temperature drops below 80/sup 0/F, the building loop may be supplied from the existing electrical hot water boilers. The Executive East Office Building is of moderate size, 25,000 sq. ft. of heated space in 2 1/2 stories. The solar system makes available for other users up to 150 KVA of existing electrical generating capacity. |
author |
Not Available |
author_facet |
Not Available |
author_sort |
Not Available |
title |
Solar heating system installed at Stamford, CT. Final report |
title_short |
Solar heating system installed at Stamford, CT. Final report |
title_full |
Solar heating system installed at Stamford, CT. Final report |
title_fullStr |
Solar heating system installed at Stamford, CT. Final report |
title_full_unstemmed |
Solar heating system installed at Stamford, CT. Final report |
title_sort |
solar heating system installed at stamford, ct. final report |
publishDate |
2013 |
url |
http://www.osti.gov/servlets/purl/5275949 https://www.osti.gov/biblio/5275949 https://doi.org/10.2172/5275949 |
genre |
North Atlantic |
genre_facet |
North Atlantic |
op_relation |
http://www.osti.gov/servlets/purl/5275949 https://www.osti.gov/biblio/5275949 https://doi.org/10.2172/5275949 doi:10.2172/5275949 |
op_doi |
https://doi.org/10.2172/5275949 |
_version_ |
1772817442728312832 |