Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters

We conducted gravity observations in Antarctica at Jang Bogo Station (JBS) during the 2019–2020 Austral summer season using an FG5-210 absolute gravimeter (AG) and a LaCoste & Romberg (LCR) Model D-58 relative gravimeter. Absolute gravity measurements were successfully made at reference gravity...

Full description

Bibliographic Details
Published in:Polar Science
Main Authors: Fukuda, Yoichi, Okuno, Jun'ichi, Doi, Koichiro, Lee, Choon-Ki
Language:English
Published: 2021
Subjects:
Online Access:https://nipr.repo.nii.ac.jp/records/16833
_version_ 1829301364252999680
author Fukuda, Yoichi
Okuno, Jun'ichi
Doi, Koichiro
Lee, Choon-Ki
author_facet Fukuda, Yoichi
Okuno, Jun'ichi
Doi, Koichiro
Lee, Choon-Ki
author_sort Fukuda, Yoichi
collection National Institute of Polar Research Repository, Japan
container_start_page 100702
container_title Polar Science
container_volume 29
description We conducted gravity observations in Antarctica at Jang Bogo Station (JBS) during the 2019–2020 Austral summer season using an FG5-210 absolute gravimeter (AG) and a LaCoste & Romberg (LCR) Model D-58 relative gravimeter. Absolute gravity measurements were successfully made at reference gravity point JBSAG1 and newly established gravity point JBSAG2, yielding about 19,000 and 14,400 drops of data, respectively, with measurement precisions better than 0.4 μGal (1 μGal = 10−8 m s−2). In addition, relative gravity measurements were conducted at 10 other newly established gravity points, with accuracies better than 10 μGal, to supplement the absolute gravity data. Superconducting gravimeter (SG) observation with an iGrav-021 instrument has been underway at JBS since 2016. Since an SG is a relative gravimeter, the calibration of the scale factor is essential for long-term gravity monitoring. In addition, the D-58 instrument was required for scale factor calibration. To calibrate the scale factors of these gravimeters, we first estimated a value for the iGrav-021 using parallel observations with the FG5-210 instrument. The D-58 scale factor was then estimated indirectly from parallel observations with the iGrav-021. These calibrations should ensure accurate gravity monitoring in future work. journal article
genre Antarc*
Antarctica
Polar Science
Polar Science
genre_facet Antarc*
Antarctica
Polar Science
Polar Science
geographic Austral
Bogo
geographic_facet Austral
Bogo
id ftnipr:oai:nipr.repo.nii.ac.jp:00016833
institution Open Polar
language English
long_lat ENVELOPE(9.783,9.783,63.095,63.095)
op_collection_id ftnipr
op_doi https://doi.org/10.1016/j.polar.2021.100702
op_relation 0.1016/j.polar.2021.100702
https://doi.org/10.1016/j.polar.2021.100702
Polar Science
29
100702
18739652
https://nipr.repo.nii.ac.jp/records/16833
op_rights metadata only access
publishDate 2021
record_format openpolar
spelling ftnipr:oai:nipr.repo.nii.ac.jp:00016833 2025-04-13T14:09:30+00:00 Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters Fukuda, Yoichi Okuno, Jun'ichi Doi, Koichiro Lee, Choon-Ki 2021-09 https://nipr.repo.nii.ac.jp/records/16833 eng eng 0.1016/j.polar.2021.100702 https://doi.org/10.1016/j.polar.2021.100702 Polar Science 29 100702 18739652 https://nipr.repo.nii.ac.jp/records/16833 metadata only access Gravity monitoring Absolute gravimeter measurement Superconducting gravimeter Scale factor calibration LaCoste D gravimeter 2021 ftnipr https://doi.org/10.1016/j.polar.2021.100702 2025-03-19T10:19:56Z We conducted gravity observations in Antarctica at Jang Bogo Station (JBS) during the 2019–2020 Austral summer season using an FG5-210 absolute gravimeter (AG) and a LaCoste & Romberg (LCR) Model D-58 relative gravimeter. Absolute gravity measurements were successfully made at reference gravity point JBSAG1 and newly established gravity point JBSAG2, yielding about 19,000 and 14,400 drops of data, respectively, with measurement precisions better than 0.4 μGal (1 μGal = 10−8 m s−2). In addition, relative gravity measurements were conducted at 10 other newly established gravity points, with accuracies better than 10 μGal, to supplement the absolute gravity data. Superconducting gravimeter (SG) observation with an iGrav-021 instrument has been underway at JBS since 2016. Since an SG is a relative gravimeter, the calibration of the scale factor is essential for long-term gravity monitoring. In addition, the D-58 instrument was required for scale factor calibration. To calibrate the scale factors of these gravimeters, we first estimated a value for the iGrav-021 using parallel observations with the FG5-210 instrument. The D-58 scale factor was then estimated indirectly from parallel observations with the iGrav-021. These calibrations should ensure accurate gravity monitoring in future work. journal article Other/Unknown Material Antarc* Antarctica Polar Science Polar Science National Institute of Polar Research Repository, Japan Austral Bogo ENVELOPE(9.783,9.783,63.095,63.095) Polar Science 29 100702
spellingShingle Gravity monitoring
Absolute gravimeter measurement
Superconducting gravimeter
Scale factor calibration
LaCoste D gravimeter
Fukuda, Yoichi
Okuno, Jun'ichi
Doi, Koichiro
Lee, Choon-Ki
Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters
title Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters
title_full Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters
title_fullStr Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters
title_full_unstemmed Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters
title_short Gravity observations at Jang Bogo Station, Antarctica, and scale factor calibrations of different relative gravimeters
title_sort gravity observations at jang bogo station, antarctica, and scale factor calibrations of different relative gravimeters
topic Gravity monitoring
Absolute gravimeter measurement
Superconducting gravimeter
Scale factor calibration
LaCoste D gravimeter
topic_facet Gravity monitoring
Absolute gravimeter measurement
Superconducting gravimeter
Scale factor calibration
LaCoste D gravimeter
url https://nipr.repo.nii.ac.jp/records/16833