Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica

P(論文) For the purpose of calibration of the superconducting gravimeter (SG) model CT#043 at Syowa Station, Antarctica, we carried out parallel observations with the absolute gravimeter (AG) FG5#210. Although the AG measurements were conducted from December 31, 2003 to February 9, 2004, SG measuremen...

Full description

Bibliographic Details
Main Authors: Fukuda, Yoichi, Iwano, Sachiko, Ikeda, Hiroshi, Hiraoka, Yoshifumi, Doi, Koichiro
Language:English
Published: National Institute of Polar Research 2005
Subjects:
Online Access:https://nipr.repo.nii.ac.jp/record/3148/files/KJ00003562984.pdf
https://doi.org/10.15094/00003148
https://nipr.repo.nii.ac.jp/records/3148
_version_ 1829309993201958912
author Fukuda, Yoichi
Iwano, Sachiko
Ikeda, Hiroshi
Hiraoka, Yoshifumi
Doi, Koichiro
author_facet Fukuda, Yoichi
Iwano, Sachiko
Ikeda, Hiroshi
Hiraoka, Yoshifumi
Doi, Koichiro
author_sort Fukuda, Yoichi
collection National Institute of Polar Research Repository, Japan
description P(論文) For the purpose of calibration of the superconducting gravimeter (SG) model CT#043 at Syowa Station, Antarctica, we carried out parallel observations with the absolute gravimeter (AG) FG5#210. Although the AG measurements were conducted from December 31, 2003 to February 9, 2004, SG measurements before January 17 are found to have suffered artificial sensitivity change. We finally adopted data from January 17 to February 1, 2004, and obtained the scale factor of CT#043 as -59.461 ±0.079μGal/volt by linear regression analysis. The result achieved a relative accuracy of around 0.1%, which is important to modern precise tidal analysis. We also determined the scale factor by comparing the data of parallel observations with the SG TT70#016. Both values showed good agreement, supporting the reliability of the above mentioned value. departmental bulletin paper
genre Antarc*
Antarctica
Polar geoscience
genre_facet Antarc*
Antarctica
Polar geoscience
geographic Syowa Station
geographic_facet Syowa Station
id ftnipr:oai:nipr.repo.nii.ac.jp:00003148
institution Open Polar
language English
op_collection_id ftnipr
op_doi https://doi.org/10.15094/00003148
op_relation Polar geoscience
18
41
48
AA1130866X
https://nipr.repo.nii.ac.jp/record/3148/files/KJ00003562984.pdf
https://doi.org/10.15094/00003148
https://nipr.repo.nii.ac.jp/records/3148
publishDate 2005
publisher National Institute of Polar Research
record_format openpolar
spelling ftnipr:oai:nipr.repo.nii.ac.jp:00003148 2025-04-13T14:08:05+00:00 Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica Fukuda, Yoichi Iwano, Sachiko Ikeda, Hiroshi Hiraoka, Yoshifumi Doi, Koichiro 2005-10 application/pdf https://nipr.repo.nii.ac.jp/record/3148/files/KJ00003562984.pdf https://doi.org/10.15094/00003148 https://nipr.repo.nii.ac.jp/records/3148 eng eng National Institute of Polar Research Polar geoscience 18 41 48 AA1130866X https://nipr.repo.nii.ac.jp/record/3148/files/KJ00003562984.pdf https://doi.org/10.15094/00003148 https://nipr.repo.nii.ac.jp/records/3148 superconducting gravimeter scale factor calibration absolute gravity measurements 2005 ftnipr https://doi.org/10.15094/00003148 2025-03-19T10:19:57Z P(論文) For the purpose of calibration of the superconducting gravimeter (SG) model CT#043 at Syowa Station, Antarctica, we carried out parallel observations with the absolute gravimeter (AG) FG5#210. Although the AG measurements were conducted from December 31, 2003 to February 9, 2004, SG measurements before January 17 are found to have suffered artificial sensitivity change. We finally adopted data from January 17 to February 1, 2004, and obtained the scale factor of CT#043 as -59.461 ±0.079μGal/volt by linear regression analysis. The result achieved a relative accuracy of around 0.1%, which is important to modern precise tidal analysis. We also determined the scale factor by comparing the data of parallel observations with the SG TT70#016. Both values showed good agreement, supporting the reliability of the above mentioned value. departmental bulletin paper Other/Unknown Material Antarc* Antarctica Polar geoscience National Institute of Polar Research Repository, Japan Syowa Station
spellingShingle superconducting gravimeter
scale factor
calibration
absolute gravity measurements
Fukuda, Yoichi
Iwano, Sachiko
Ikeda, Hiroshi
Hiraoka, Yoshifumi
Doi, Koichiro
Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica
title Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica
title_full Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica
title_fullStr Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica
title_full_unstemmed Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica
title_short Calibration of the superconducting gravimeter CT#043 with an absolute gravimeter FG5#210 at Syowa Station, Antarctica
title_sort calibration of the superconducting gravimeter ct#043 with an absolute gravimeter fg5#210 at syowa station, antarctica
topic superconducting gravimeter
scale factor
calibration
absolute gravity measurements
topic_facet superconducting gravimeter
scale factor
calibration
absolute gravity measurements
url https://nipr.repo.nii.ac.jp/record/3148/files/KJ00003562984.pdf
https://doi.org/10.15094/00003148
https://nipr.repo.nii.ac.jp/records/3148