Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure

P(論文) A new type of Aitken nuclei sonde is reported. The sonde consists of an expansion fog chamber, which is similar in principle to the Pollak counter or the Aitken counter, as a measuring device of Aitken unclei concentration. The most important characteristics of the present fog chamber are that...

Full description

Bibliographic Details
Main Authors: Ito, Tomoyuki, Ikegami, Miwako, Kanazawa, Izuo
Language:English
Published: 1983
Subjects:
Online Access:https://nipr.repo.nii.ac.jp/record/1513/files/KJ00000012146.pdf
https://nipr.repo.nii.ac.jp/records/1513
_version_ 1829311288237359104
author Ito, Tomoyuki
Ikegami, Miwako
Kanazawa, Izuo
author_facet Ito, Tomoyuki
Ikegami, Miwako
Kanazawa, Izuo
author_sort Ito, Tomoyuki
collection National Institute of Polar Research Repository, Japan
description P(論文) A new type of Aitken nuclei sonde is reported. The sonde consists of an expansion fog chamber, which is similar in principle to the Pollak counter or the Aitken counter, as a measuring device of Aitken unclei concentration. The most important characteristics of the present fog chamber are that it is a very compact automatic one and it has a construction to keep expansion ratio constant irrespective of ambient pressure. The constant expansion ratio is an essential requirement for the measurement of Aitken nuclei concentration at different heights by a balloon or an airplane. The variation of measured values during 50 times measurement for a same air sample is smaller than 3% of the mean. Two identical fog chambers in the present sonde give Aitken unclei concentrations which agree within 50(cm)^<-3> for the concentration range covering between about 200 and about 2000cm^<-3>. A nuclei measuring signal is inserted into rawinsonde signal, which is transmitted to a ground station, every minute for 10s. The total weight of a sonde is 9kg, comprising a 5kg fog chamber, a 3.5kg battery and a 0.5kg rawinsonde. departmental bulletin paper
genre Memoirs of National Institute of Polar Research
Polar Research
genre_facet Memoirs of National Institute of Polar Research
Polar Research
geographic Aitken
geographic_facet Aitken
id ftnipr:oai:nipr.repo.nii.ac.jp:00001513
institution Open Polar
language English
long_lat ENVELOPE(-44.516,-44.516,-60.733,-60.733)
op_collection_id ftnipr
op_relation Memoirs of National Institute of Polar Research. Special issue
29
185
190
AA00733561
https://nipr.repo.nii.ac.jp/record/1513/files/KJ00000012146.pdf
https://nipr.repo.nii.ac.jp/records/1513
publishDate 1983
record_format openpolar
spelling ftnipr:oai:nipr.repo.nii.ac.jp:00001513 2025-04-13T14:22:34+00:00 Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure Ito, Tomoyuki Ikegami, Miwako Kanazawa, Izuo 1983-11 application/pdf https://nipr.repo.nii.ac.jp/record/1513/files/KJ00000012146.pdf https://nipr.repo.nii.ac.jp/records/1513 eng eng Memoirs of National Institute of Polar Research. Special issue 29 185 190 AA00733561 https://nipr.repo.nii.ac.jp/record/1513/files/KJ00000012146.pdf https://nipr.repo.nii.ac.jp/records/1513 1983 ftnipr 2025-03-19T10:19:56Z P(論文) A new type of Aitken nuclei sonde is reported. The sonde consists of an expansion fog chamber, which is similar in principle to the Pollak counter or the Aitken counter, as a measuring device of Aitken unclei concentration. The most important characteristics of the present fog chamber are that it is a very compact automatic one and it has a construction to keep expansion ratio constant irrespective of ambient pressure. The constant expansion ratio is an essential requirement for the measurement of Aitken nuclei concentration at different heights by a balloon or an airplane. The variation of measured values during 50 times measurement for a same air sample is smaller than 3% of the mean. Two identical fog chambers in the present sonde give Aitken unclei concentrations which agree within 50(cm)^<-3> for the concentration range covering between about 200 and about 2000cm^<-3>. A nuclei measuring signal is inserted into rawinsonde signal, which is transmitted to a ground station, every minute for 10s. The total weight of a sonde is 9kg, comprising a 5kg fog chamber, a 3.5kg battery and a 0.5kg rawinsonde. departmental bulletin paper Other/Unknown Material Memoirs of National Institute of Polar Research Polar Research National Institute of Polar Research Repository, Japan Aitken ENVELOPE(-44.516,-44.516,-60.733,-60.733)
spellingShingle Ito, Tomoyuki
Ikegami, Miwako
Kanazawa, Izuo
Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure
title Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure
title_full Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure
title_fullStr Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure
title_full_unstemmed Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure
title_short Aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure
title_sort aitken nuclei sonde with constant expansion ratio irrespective of ambient pressure
url https://nipr.repo.nii.ac.jp/record/1513/files/KJ00000012146.pdf
https://nipr.repo.nii.ac.jp/records/1513