Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015.

The concentrations of the measured components are generally low and below national limit values for the protection of human health and critical levels for the protection of vegetation. Wind from northern sectors gave the highest average concentrations of nitrogen oxides, which indicates the power st...

Full description

Bibliographic Details
Main Authors: Johnsrud, Mona, Hermansen, Ove, Tørnkvist, Kjersti Karlsen
Format: Report
Language:English
Published: NILU 2016
Subjects:
Online Access:http://hdl.handle.net/11250/2432683
id ftnilu:oai:nilu.brage.unit.no:11250/2432683
record_format openpolar
spelling ftnilu:oai:nilu.brage.unit.no:11250/2432683 2023-07-30T04:04:26+02:00 Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015. Luftkvalitet i Ny‐Ålesund. Målinger av lokal luftkvalitet 2014‐2015. Johnsrud, Mona Hermansen, Ove Tørnkvist, Kjersti Karlsen 2016 application/pdf http://hdl.handle.net/11250/2432683 eng eng NILU NILU report NILU report;35/2016 Johnsrud, M., Hermansen, O. and Tørnkvist, K. (2016). Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015 (NILU report, 35/2016). Kjeller: NILU. urn:isbn:978-82-425-2866-7 urn:issn:2464-3327 http://hdl.handle.net/11250/2432683 cristin:1454664 © NILU – Norwegian Institute for Air Research. The publication may be freely cited where the source is acknowledged. 26 35/2016 Research report 2016 ftnilu 2023-07-08T19:54:20Z The concentrations of the measured components are generally low and below national limit values for the protection of human health and critical levels for the protection of vegetation. Wind from northern sectors gave the highest average concentrations of nitrogen oxides, which indicates the power station and the harbour as possible sources. From September 2014 to February 2015, volcanic eruptions at Iceland emitted large volumes of SO2, which gave episodes of elevated concentrations in Ny-Ålesund. The measurement results for CO2 show an annual variation with higher concentrations in the winter and lower in summer. Measured concentrations of CO were most likely caused by local snowmobile traffic and long-range transport of emissions from wildfires in North America. De målte konsentrasjonene var generelt lave for alle komponenter og under nasjonale grenseverdier for beskyttelse av menneskets helse og økosystemet. Vind fra nordlige sektorer ga de høyeste gjennomsnittskonsentrasjonene av nitrogenoksider, noe som peker på kraftstasjonen og havnen som mulige kilder. Fra september 2014 til februar 2015 ga vulkanutbrudd på Island store utslipp av SO2, som ga episoder med høye konsentrasjoner i Ny‐Ålesund. Måleresultatene fro CO2 viser en årlig variasjon, med høyere konsentrasjoner om vinteren og lavere om sommeren. Kilder for de målte konsentrasjonene av CO var mest sannsynlig lokal snøskutertrafikk og langtransporterte utslipp fra skogbranner i Nord‐Amerika. Report Iceland Ny Ålesund Ny-Ålesund NILU – Norwegian Institute for Air Research: NILU Brage Ny-Ålesund
institution Open Polar
collection NILU – Norwegian Institute for Air Research: NILU Brage
op_collection_id ftnilu
language English
description The concentrations of the measured components are generally low and below national limit values for the protection of human health and critical levels for the protection of vegetation. Wind from northern sectors gave the highest average concentrations of nitrogen oxides, which indicates the power station and the harbour as possible sources. From September 2014 to February 2015, volcanic eruptions at Iceland emitted large volumes of SO2, which gave episodes of elevated concentrations in Ny-Ålesund. The measurement results for CO2 show an annual variation with higher concentrations in the winter and lower in summer. Measured concentrations of CO were most likely caused by local snowmobile traffic and long-range transport of emissions from wildfires in North America. De målte konsentrasjonene var generelt lave for alle komponenter og under nasjonale grenseverdier for beskyttelse av menneskets helse og økosystemet. Vind fra nordlige sektorer ga de høyeste gjennomsnittskonsentrasjonene av nitrogenoksider, noe som peker på kraftstasjonen og havnen som mulige kilder. Fra september 2014 til februar 2015 ga vulkanutbrudd på Island store utslipp av SO2, som ga episoder med høye konsentrasjoner i Ny‐Ålesund. Måleresultatene fro CO2 viser en årlig variasjon, med høyere konsentrasjoner om vinteren og lavere om sommeren. Kilder for de målte konsentrasjonene av CO var mest sannsynlig lokal snøskutertrafikk og langtransporterte utslipp fra skogbranner i Nord‐Amerika.
format Report
author Johnsrud, Mona
Hermansen, Ove
Tørnkvist, Kjersti Karlsen
spellingShingle Johnsrud, Mona
Hermansen, Ove
Tørnkvist, Kjersti Karlsen
Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015.
author_facet Johnsrud, Mona
Hermansen, Ove
Tørnkvist, Kjersti Karlsen
author_sort Johnsrud, Mona
title Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015.
title_short Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015.
title_full Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015.
title_fullStr Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015.
title_full_unstemmed Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015.
title_sort air quality in ny-ålesund. monitoring of local air quality 2014-2015.
publisher NILU
publishDate 2016
url http://hdl.handle.net/11250/2432683
geographic Ny-Ålesund
geographic_facet Ny-Ålesund
genre Iceland
Ny Ålesund
Ny-Ålesund
genre_facet Iceland
Ny Ålesund
Ny-Ålesund
op_source 26
35/2016
op_relation NILU report
NILU report;35/2016
Johnsrud, M., Hermansen, O. and Tørnkvist, K. (2016). Air quality in Ny-Ålesund. Monitoring of local air quality 2014-2015 (NILU report, 35/2016). Kjeller: NILU.
urn:isbn:978-82-425-2866-7
urn:issn:2464-3327
http://hdl.handle.net/11250/2432683
cristin:1454664
op_rights © NILU – Norwegian Institute for Air Research. The publication may be freely cited where the source is acknowledged.
_version_ 1772815873830027264