Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines

Thesis (M.E.S.), Memorial University of Newfoundland, 1999. Environmental Science Bibliography: p. 175-183 Trace element analysis in the earth and environmental sciences requires accurate and precise determination of element concentration in geological samples. Inductively coupled plasma-mass spectr...

Full description

Bibliographic Details
Main Author: Diegor, Wilfredo G., 1956-
Other Authors: Memorial University of Newfoundland. Environmental Science
Format: Text
Language:English
Published: 1999
Subjects:
Online Access:http://collections.mun.ca/cdm/ref/collection/theses4/id/121359
id ftmemorialunivdc:oai:collections.mun.ca:theses4/121359
record_format openpolar
institution Open Polar
collection Memorial University of Newfoundland: Digital Archives Initiative (DAI)
op_collection_id ftmemorialunivdc
language English
topic Trace elements--Analysis
Inductively coupled plasma mass spectrometry
River sediments--Philippines--Cebu
Urban soils--Philippines--Cebu
spellingShingle Trace elements--Analysis
Inductively coupled plasma mass spectrometry
River sediments--Philippines--Cebu
Urban soils--Philippines--Cebu
Diegor, Wilfredo G., 1956-
Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines
topic_facet Trace elements--Analysis
Inductively coupled plasma mass spectrometry
River sediments--Philippines--Cebu
Urban soils--Philippines--Cebu
description Thesis (M.E.S.), Memorial University of Newfoundland, 1999. Environmental Science Bibliography: p. 175-183 Trace element analysis in the earth and environmental sciences requires accurate and precise determination of element concentration in geological samples. Inductively coupled plasma-mass spectrometry (ICP-MS) continues to provide reliable data in this area. Analytical concerns in solution ÏCP-MS include completeness of digestion and volatilization loss. The work embodied in this thesis examined the use of high pressure digestion to address incompleteness of digestion in the analysis of geological materials. -- High pressure digestion vessels (HPDV) fabricated in-house were compared with the existing method at Memorial University of Newfoundland which uses screw top Teflon (STT) jars in digesting several geochemical reference materials (GRMs). ICP-MS analysis of the solutions using the MUN ICP-MS trace element package demonstrated more complete digestion of the marine sediment GRMs PACS-1, MESS-2 and BSK-1, indicated by higher Y, Zr, Nb, HREE, Hf and U values when the HPDV was used. Zirconium was from 40% to 150% higher, Hf was 35% to 120% higher, and the HREEs were generally higher by about 20% in the HPDV than in the routine method. The results indicate better decomposition of resistant minerals especially zircon grains that were likely in high abundance in the sediments. No significant difference between STT and HPDV was found for the other GRMs (basalt, andésite, gabbro, dolente and syenite). Lower element values for the granite material, G-2, were obtained in the HPDV, but Zr and Hf values were still significantly higher than in the STT. Rubidium was poorly recovered in the marine sediments, the reason for which has not been determined in the study. -- An ICP-MS data acquisition and reduction procedure (environmental-exploration package) was developed to determine transition metals and other trace elements in geological samples. Twenty-nine masses comprised the element suite: 51V, 52Cr, 55Mn, 59Co, 60Ni, 65Cu, 66Zn, 75As, 77Se, 79Br, 98Mo, 107Ag, 111Cd, 118Sn, 121Sb, 125Te, 127I 139La, 140Ce, 141Pr, 145Nd, 167Er, 169Tm, 175Lu, 183W, 201Hg, 208Pb, 209Bi and 232Th. Most important interferences were from 43Ca16O on 59Co, 44Ca16O on 60Ni, 49Ti16O on 65Cu and 50Ti16O on 66Zn. Internal standards used were 45Sc, 115In and 187Re. 238U and 254(UO) were measured to monitor polyatomic ion formation. Sensitivity of the elements was calculated from one of 2 external standards, except for 3 elements which were calibrated through surrogate calibration (Sn using Sb, W using Lu, and Hg using Pb). Calibration was demonstrated to be successful for the pair Sn-Sb; though not as good for W-Lu, probably due to laboratory contamination. Surrogate calibration for the pair Hg-Pb proved unsuccessful, most probably because of volatilization loss of Hg during sample digestion. Analysis of reference materials using the new package showed excellent results for V, Co, Cr, Ni, Sn, Sb, Cu, Zn, Mo, Cd and Pb compared with literature values. Arsenic and Ag results were mostly near detection limits. Comparison with XRF results indicated good agreement between the environmental-exploration package and the XRF. Compared with the MUN ICP-MS trace element package, the new package was in good agreement for the elements Mo, La, Ce, Pr, Nd, Er, Tm, Lu, Pb, Bi and Th. -- The high pressure digestion technique and the ICP-MS environmental-exploration package were applied to the analysis of urban stream sediment and soil samples from the Philippines. Good correlation for La, Ce, Pr, Nd, Er, Tm, Lu, Pb, Bi and Th between the package and the MUN ICP-MS trace results was shown by the high correlation coefficients derived. Nickel and As gave poor results because of the high concentrations in the calibration blanks for Ni and possibly because of volatility for As. Particle size may also have influenced the results for these 2 elements because results for the reference materials indicated good agreement between the XRF and the environmental-exploration package. It was found that the GRMs are significantly finer grained than the stream sediment and soil samples (greater <53 μm fraction), suggesting that there may be a need to grind the stream sediment and soil samples to obtain better results. -- Mapping of empirically derived geochemical classes showed that the spatial distribution of Cr, Ni, Cu, Zn, Pb, Sn, Sb and Cd in the stream sediments correspond to the large commercial zone in the SW portion of the study area. Higher values of Cu and Zn point to an industrial zone to the east. The soil element data correspond to an industrial zone where manufacturing and use of metal parts abound. Arsenic was high in the relatively new land development to the SW, which was a she where storm drainage and airline night soil from the nearby air facility previously collected. Except for Sb and Cd, the element concentration in the stream sediments were high for a limestone terrain. The soil samples likewise indicated input from human activity. The derived geochemical landscape coincided with the known land use in the area.
author2 Memorial University of Newfoundland. Environmental Science
format Text
author Diegor, Wilfredo G., 1956-
author_facet Diegor, Wilfredo G., 1956-
author_sort Diegor, Wilfredo G., 1956-
title Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines
title_short Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines
title_full Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines
title_fullStr Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines
title_full_unstemmed Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines
title_sort development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the icp-ms analysis of urban sediments and soils from cebu, philippines
publishDate 1999
url http://collections.mun.ca/cdm/ref/collection/theses4/id/121359
genre Newfoundland studies
University of Newfoundland
genre_facet Newfoundland studies
University of Newfoundland
op_source Paper copy kept in the Centre for Newfoundland Studies, Memorial University Libraries
op_relation Electronic Theses and Dissertations
(22.77 MB) -- http://collections.mun.ca/PDFs/theses/Diegor_WilfredoG.pdf
a1355684
http://collections.mun.ca/cdm/ref/collection/theses4/id/121359
op_rights The author retains copyright ownership and moral rights in this thesis. Neither the thesis nor substantial extracts from it may be printed or otherwise reproduced without the author's permission.
_version_ 1766113310961303552
spelling ftmemorialunivdc:oai:collections.mun.ca:theses4/121359 2023-05-15T17:23:33+02:00 Development of a high pressure digestion technique and a data acquisition/reduction procedure and their application to the ICP-MS analysis of urban sediments and soils from Cebu, Philippines Diegor, Wilfredo G., 1956- Memorial University of Newfoundland. Environmental Science 1999 192 leaves : ill. Image/jpeg; Application/pdf http://collections.mun.ca/cdm/ref/collection/theses4/id/121359 Eng eng Electronic Theses and Dissertations (22.77 MB) -- http://collections.mun.ca/PDFs/theses/Diegor_WilfredoG.pdf a1355684 http://collections.mun.ca/cdm/ref/collection/theses4/id/121359 The author retains copyright ownership and moral rights in this thesis. Neither the thesis nor substantial extracts from it may be printed or otherwise reproduced without the author's permission. Paper copy kept in the Centre for Newfoundland Studies, Memorial University Libraries Trace elements--Analysis Inductively coupled plasma mass spectrometry River sediments--Philippines--Cebu Urban soils--Philippines--Cebu Text 1999 ftmemorialunivdc 2015-08-06T19:22:24Z Thesis (M.E.S.), Memorial University of Newfoundland, 1999. Environmental Science Bibliography: p. 175-183 Trace element analysis in the earth and environmental sciences requires accurate and precise determination of element concentration in geological samples. Inductively coupled plasma-mass spectrometry (ICP-MS) continues to provide reliable data in this area. Analytical concerns in solution ÏCP-MS include completeness of digestion and volatilization loss. The work embodied in this thesis examined the use of high pressure digestion to address incompleteness of digestion in the analysis of geological materials. -- High pressure digestion vessels (HPDV) fabricated in-house were compared with the existing method at Memorial University of Newfoundland which uses screw top Teflon (STT) jars in digesting several geochemical reference materials (GRMs). ICP-MS analysis of the solutions using the MUN ICP-MS trace element package demonstrated more complete digestion of the marine sediment GRMs PACS-1, MESS-2 and BSK-1, indicated by higher Y, Zr, Nb, HREE, Hf and U values when the HPDV was used. Zirconium was from 40% to 150% higher, Hf was 35% to 120% higher, and the HREEs were generally higher by about 20% in the HPDV than in the routine method. The results indicate better decomposition of resistant minerals especially zircon grains that were likely in high abundance in the sediments. No significant difference between STT and HPDV was found for the other GRMs (basalt, andésite, gabbro, dolente and syenite). Lower element values for the granite material, G-2, were obtained in the HPDV, but Zr and Hf values were still significantly higher than in the STT. Rubidium was poorly recovered in the marine sediments, the reason for which has not been determined in the study. -- An ICP-MS data acquisition and reduction procedure (environmental-exploration package) was developed to determine transition metals and other trace elements in geological samples. Twenty-nine masses comprised the element suite: 51V, 52Cr, 55Mn, 59Co, 60Ni, 65Cu, 66Zn, 75As, 77Se, 79Br, 98Mo, 107Ag, 111Cd, 118Sn, 121Sb, 125Te, 127I 139La, 140Ce, 141Pr, 145Nd, 167Er, 169Tm, 175Lu, 183W, 201Hg, 208Pb, 209Bi and 232Th. Most important interferences were from 43Ca16O on 59Co, 44Ca16O on 60Ni, 49Ti16O on 65Cu and 50Ti16O on 66Zn. Internal standards used were 45Sc, 115In and 187Re. 238U and 254(UO) were measured to monitor polyatomic ion formation. Sensitivity of the elements was calculated from one of 2 external standards, except for 3 elements which were calibrated through surrogate calibration (Sn using Sb, W using Lu, and Hg using Pb). Calibration was demonstrated to be successful for the pair Sn-Sb; though not as good for W-Lu, probably due to laboratory contamination. Surrogate calibration for the pair Hg-Pb proved unsuccessful, most probably because of volatilization loss of Hg during sample digestion. Analysis of reference materials using the new package showed excellent results for V, Co, Cr, Ni, Sn, Sb, Cu, Zn, Mo, Cd and Pb compared with literature values. Arsenic and Ag results were mostly near detection limits. Comparison with XRF results indicated good agreement between the environmental-exploration package and the XRF. Compared with the MUN ICP-MS trace element package, the new package was in good agreement for the elements Mo, La, Ce, Pr, Nd, Er, Tm, Lu, Pb, Bi and Th. -- The high pressure digestion technique and the ICP-MS environmental-exploration package were applied to the analysis of urban stream sediment and soil samples from the Philippines. Good correlation for La, Ce, Pr, Nd, Er, Tm, Lu, Pb, Bi and Th between the package and the MUN ICP-MS trace results was shown by the high correlation coefficients derived. Nickel and As gave poor results because of the high concentrations in the calibration blanks for Ni and possibly because of volatility for As. Particle size may also have influenced the results for these 2 elements because results for the reference materials indicated good agreement between the XRF and the environmental-exploration package. It was found that the GRMs are significantly finer grained than the stream sediment and soil samples (greater <53 μm fraction), suggesting that there may be a need to grind the stream sediment and soil samples to obtain better results. -- Mapping of empirically derived geochemical classes showed that the spatial distribution of Cr, Ni, Cu, Zn, Pb, Sn, Sb and Cd in the stream sediments correspond to the large commercial zone in the SW portion of the study area. Higher values of Cu and Zn point to an industrial zone to the east. The soil element data correspond to an industrial zone where manufacturing and use of metal parts abound. Arsenic was high in the relatively new land development to the SW, which was a she where storm drainage and airline night soil from the nearby air facility previously collected. Except for Sb and Cd, the element concentration in the stream sediments were high for a limestone terrain. The soil samples likewise indicated input from human activity. The derived geochemical landscape coincided with the known land use in the area. Text Newfoundland studies University of Newfoundland Memorial University of Newfoundland: Digital Archives Initiative (DAI)