Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System

We present the building performance of a house in Newfoundland. This house is built under the guidelines of the Passive House Institute United States (PHIUS+2015) standards. This is an important step took towards sustainable living in Newfoundland and Canada in general. Detailed energy consumption m...

Full description

Bibliographic Details
Published in:International Journal of Renewable Energy Research
Main Authors: Iqbal, Mohamed T., Manzoor, Sabir, Goodyear, David J.
Format: Article in Journal/Newspaper
Language:English
Published: Gazi University 2020
Subjects:
Online Access:https://research.library.mun.ca/16219/
https://research.library.mun.ca/16219/1/document.pdf
https://doi.org/10.20508/ijrer.v10i3.11165.g7997
id ftmemorialuniv:oai:research.library.mun.ca:16219
record_format openpolar
spelling ftmemorialuniv:oai:research.library.mun.ca:16219 2023-12-17T10:42:34+01:00 Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System Iqbal, Mohamed T. Manzoor, Sabir Goodyear, David J. 2020-09 application/pdf https://research.library.mun.ca/16219/ https://research.library.mun.ca/16219/1/document.pdf https://doi.org/10.20508/ijrer.v10i3.11165.g7997 en eng Gazi University https://research.library.mun.ca/16219/1/document.pdf Iqbal, Mohamed T. <https://research.library.mun.ca/view/creator_az/Iqbal=3AMohamed_T=2E=3A=3A.html> and Manzoor, Sabir <https://research.library.mun.ca/view/creator_az/Manzoor=3ASabir=3A=3A.html> and Goodyear, David J. <https://research.library.mun.ca/view/creator_az/Goodyear=3ADavid_J=2E=3A=3A.html> (2020) Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System. International Journal of Renewable Energy Research, 10 (3). ISSN 1309-0127 cc_by_nc Article PeerReviewed 2020 ftmemorialuniv https://doi.org/10.20508/ijrer.v10i3.11165.g7997 2023-11-19T00:12:36Z We present the building performance of a house in Newfoundland. This house is built under the guidelines of the Passive House Institute United States (PHIUS+2015) standards. This is an important step took towards sustainable living in Newfoundland and Canada in general. Detailed energy consumption modelling of the house has been performed along with the steps involved in the simulation process of Passive House planning and renewable energy system sizing. A significant part of the study presents the majority of the construction details of the house and the components involved. In this study, we present actual energy consumption data acquired from the house and the simulation performed in both pre-construction and post-construction phases. Additionally, steps followed during the planning and construction phase have been discussed in detail, and both static and dynamic energy modelling has been compared. Moreover, a cost comparison has been performed to calculate all the additional costs spent on the resources to build the house according to the Passive House (PHIUS+2015) standards; the analysis indicated a cost of 12% extra when compared with the house built under local regulations. Finally, a renewable energy system is proposed for the house to meet the electricity needs of the house. Article in Journal/Newspaper Newfoundland Memorial University of Newfoundland: Research Repository Canada International Journal of Renewable Energy Research v10i3
institution Open Polar
collection Memorial University of Newfoundland: Research Repository
op_collection_id ftmemorialuniv
language English
description We present the building performance of a house in Newfoundland. This house is built under the guidelines of the Passive House Institute United States (PHIUS+2015) standards. This is an important step took towards sustainable living in Newfoundland and Canada in general. Detailed energy consumption modelling of the house has been performed along with the steps involved in the simulation process of Passive House planning and renewable energy system sizing. A significant part of the study presents the majority of the construction details of the house and the components involved. In this study, we present actual energy consumption data acquired from the house and the simulation performed in both pre-construction and post-construction phases. Additionally, steps followed during the planning and construction phase have been discussed in detail, and both static and dynamic energy modelling has been compared. Moreover, a cost comparison has been performed to calculate all the additional costs spent on the resources to build the house according to the Passive House (PHIUS+2015) standards; the analysis indicated a cost of 12% extra when compared with the house built under local regulations. Finally, a renewable energy system is proposed for the house to meet the electricity needs of the house.
format Article in Journal/Newspaper
author Iqbal, Mohamed T.
Manzoor, Sabir
Goodyear, David J.
spellingShingle Iqbal, Mohamed T.
Manzoor, Sabir
Goodyear, David J.
Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System
author_facet Iqbal, Mohamed T.
Manzoor, Sabir
Goodyear, David J.
author_sort Iqbal, Mohamed T.
title Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System
title_short Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System
title_full Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System
title_fullStr Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System
title_full_unstemmed Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System
title_sort building performance modelling for the first house in newfoundland built on phius+2015 standards and design of renewable energy system
publisher Gazi University
publishDate 2020
url https://research.library.mun.ca/16219/
https://research.library.mun.ca/16219/1/document.pdf
https://doi.org/10.20508/ijrer.v10i3.11165.g7997
geographic Canada
geographic_facet Canada
genre Newfoundland
genre_facet Newfoundland
op_relation https://research.library.mun.ca/16219/1/document.pdf
Iqbal, Mohamed T. <https://research.library.mun.ca/view/creator_az/Iqbal=3AMohamed_T=2E=3A=3A.html> and Manzoor, Sabir <https://research.library.mun.ca/view/creator_az/Manzoor=3ASabir=3A=3A.html> and Goodyear, David J. <https://research.library.mun.ca/view/creator_az/Goodyear=3ADavid_J=2E=3A=3A.html> (2020) Building Performance Modelling for the First House in Newfoundland Built on PHIUS+2015 Standards and Design of Renewable Energy System. International Journal of Renewable Energy Research, 10 (3). ISSN 1309-0127
op_rights cc_by_nc
op_doi https://doi.org/10.20508/ijrer.v10i3.11165.g7997
container_title International Journal of Renewable Energy Research
container_issue v10i3
_version_ 1785554202299203584