Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis
This paper deals with gas-leakage detection and isolation in a fine coal injection vessel for a blast furnace process. Functions describing the expected time-domain behaviour of different leakages are developed, thus reducing the leakage isolation problem to pattern recognition. In order to lower th...
Published in: | Proceedings of the 1998 IEEE International Conference on Control Applications (Cat. No.98CH36104) |
---|---|
Main Authors: | , , |
Format: | Conference Object |
Language: | English |
Published: |
Luleå tekniska universitet, Signaler och system
1998
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-37811 https://doi.org/10.1109/CCA.1998.728368 |
_version_ | 1821577805315440640 |
---|---|
author | Johansson, Andreas Birk, Wolfgang Medvedev, Alexander |
author_facet | Johansson, Andreas Birk, Wolfgang Medvedev, Alexander |
author_sort | Johansson, Andreas |
collection | Luleå University of Technology Publications (DiVA) |
container_start_page | 212 |
container_title | Proceedings of the 1998 IEEE International Conference on Control Applications (Cat. No.98CH36104) |
container_volume | 1 |
description | This paper deals with gas-leakage detection and isolation in a fine coal injection vessel for a blast furnace process. Functions describing the expected time-domain behaviour of different leakages are developed, thus reducing the leakage isolation problem to pattern recognition. In order to lower the computational burden while preserving the essential dynamic behaviour of a leakage, a truncated Laguerre series representation is used. The Generalized Likelihood Ratio methos is employed to compare the Laguerre of the residual with the Laguerre spectra of the predefined typical leakage functions. Tests of the developed algorithm have been successfully performed at SSAB Tunnplåt, Luleå. Godkänd; 1998; 20061025 (ysko) |
format | Conference Object |
genre | Luleå Luleå Luleå |
genre_facet | Luleå Luleå Luleå |
id | ftluleatu:oai:DiVA.org:ltu-37811 |
institution | Open Polar |
language | English |
op_collection_id | ftluleatu |
op_container_end_page | 216 |
op_doi | https://doi.org/10.1109/CCA.1998.728368 |
op_relation | Proceedings of the 1998 IEEE International Conference on Control Applications : September 1 - 4, 1998, Stazione Marittima Congress Center, Trieste, Italy, p. 212-216 doi:10.1109/CCA.1998.728368 |
op_rights | info:eu-repo/semantics/openAccess |
publishDate | 1998 |
publisher | Luleå tekniska universitet, Signaler och system |
record_format | openpolar |
spelling | ftluleatu:oai:DiVA.org:ltu-37811 2025-01-16T23:01:11+00:00 Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis Johansson, Andreas Birk, Wolfgang Medvedev, Alexander 1998 application/pdf http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-37811 https://doi.org/10.1109/CCA.1998.728368 eng eng Luleå tekniska universitet, Signaler och system Luleå tekniska universitet, Institutionen för system- och rymdteknik Piscataway, NJ Proceedings of the 1998 IEEE International Conference on Control Applications : September 1 - 4, 1998, Stazione Marittima Congress Center, Trieste, Italy, p. 212-216 doi:10.1109/CCA.1998.728368 info:eu-repo/semantics/openAccess Control Engineering Reglerteknik Conference paper info:eu-repo/semantics/conferenceObject text 1998 ftluleatu https://doi.org/10.1109/CCA.1998.728368 2024-12-18T12:24:46Z This paper deals with gas-leakage detection and isolation in a fine coal injection vessel for a blast furnace process. Functions describing the expected time-domain behaviour of different leakages are developed, thus reducing the leakage isolation problem to pattern recognition. In order to lower the computational burden while preserving the essential dynamic behaviour of a leakage, a truncated Laguerre series representation is used. The Generalized Likelihood Ratio methos is employed to compare the Laguerre of the residual with the Laguerre spectra of the predefined typical leakage functions. Tests of the developed algorithm have been successfully performed at SSAB Tunnplåt, Luleå. Godkänd; 1998; 20061025 (ysko) Conference Object Luleå Luleå Luleå Luleå University of Technology Publications (DiVA) Proceedings of the 1998 IEEE International Conference on Control Applications (Cat. No.98CH36104) 1 212 216 |
spellingShingle | Control Engineering Reglerteknik Johansson, Andreas Birk, Wolfgang Medvedev, Alexander Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis |
title | Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis |
title_full | Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis |
title_fullStr | Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis |
title_full_unstemmed | Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis |
title_short | Model-based gas leakage detection and isolation in a pressurized system via Laguerre spectrum analysis |
title_sort | model-based gas leakage detection and isolation in a pressurized system via laguerre spectrum analysis |
topic | Control Engineering Reglerteknik |
topic_facet | Control Engineering Reglerteknik |
url | http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-37811 https://doi.org/10.1109/CCA.1998.728368 |