Telemedicin enabled mobile pulse and blood pressure sensor

The last course, in the MSc in Electrical Engineering - Industrial Electronics, at Luleå University of Technology, is a project course. This year the goal was to produce a blood pressure and pulse measurement device. It was supposed to be used in elderly care since it is an inconvenience for them to...

Full description

Bibliographic Details
Main Author: Cabrerizo, Ana Belén
Format: Report
Language:English
Published: Luleå tekniska universitet, EISLAB 2000
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-25527
_version_ 1821577912231395328
author Cabrerizo, Ana Belén
author_facet Cabrerizo, Ana Belén
author_sort Cabrerizo, Ana Belén
collection Luleå University of Technology Publications (DiVA)
description The last course, in the MSc in Electrical Engineering - Industrial Electronics, at Luleå University of Technology, is a project course. This year the goal was to produce a blood pressure and pulse measurement device. It was supposed to be used in elderly care since it is an inconvenience for them to have to go to a hospital just to measure their pulse and blood pressure. With this device these measurements can be made in their home environment which would help them to relax and make the measurement more accurate. A doctor would also be relieved of a lot of work since he would be able to run measurements parallel with other work and then come back to analyse them at a later point. It would also be easier to compare with previous measurements since it would be possible to store the measurements from each patient on "their own" homepage. The device is built around a Mitsubishi processor, M16C/62, and it communicates with Internet via Ethernet and Bluetooth. The report describes how the problems were solved and what was produced by the groups in the different areas such as the processor, electromechanics, user interface and Bluetooth. Antenna AB was our partner in working with this project. Godkänd; 2000; 20091001 (ysko)
format Report
genre Luleå
Luleå
Luleå
genre_facet Luleå
Luleå
Luleå
id ftluleatu:oai:DiVA.org:ltu-25527
institution Open Polar
language English
op_collection_id ftluleatu
op_rights info:eu-repo/semantics/openAccess
publishDate 2000
publisher Luleå tekniska universitet, EISLAB
record_format openpolar
spelling ftluleatu:oai:DiVA.org:ltu-25527 2025-01-16T23:01:18+00:00 Telemedicin enabled mobile pulse and blood pressure sensor Cabrerizo, Ana Belén 2000 application/pdf http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-25527 eng eng Luleå tekniska universitet, EISLAB Luleå info:eu-repo/semantics/openAccess Other Electrical Engineering Electronic Engineering Information Engineering Annan elektroteknik och elektronik Report info:eu-repo/semantics/report text 2000 ftluleatu 2024-12-18T12:24:47Z The last course, in the MSc in Electrical Engineering - Industrial Electronics, at Luleå University of Technology, is a project course. This year the goal was to produce a blood pressure and pulse measurement device. It was supposed to be used in elderly care since it is an inconvenience for them to have to go to a hospital just to measure their pulse and blood pressure. With this device these measurements can be made in their home environment which would help them to relax and make the measurement more accurate. A doctor would also be relieved of a lot of work since he would be able to run measurements parallel with other work and then come back to analyse them at a later point. It would also be easier to compare with previous measurements since it would be possible to store the measurements from each patient on "their own" homepage. The device is built around a Mitsubishi processor, M16C/62, and it communicates with Internet via Ethernet and Bluetooth. The report describes how the problems were solved and what was produced by the groups in the different areas such as the processor, electromechanics, user interface and Bluetooth. Antenna AB was our partner in working with this project. Godkänd; 2000; 20091001 (ysko) Report Luleå Luleå Luleå Luleå University of Technology Publications (DiVA)
spellingShingle Other Electrical Engineering
Electronic Engineering
Information Engineering
Annan elektroteknik och elektronik
Cabrerizo, Ana Belén
Telemedicin enabled mobile pulse and blood pressure sensor
title Telemedicin enabled mobile pulse and blood pressure sensor
title_full Telemedicin enabled mobile pulse and blood pressure sensor
title_fullStr Telemedicin enabled mobile pulse and blood pressure sensor
title_full_unstemmed Telemedicin enabled mobile pulse and blood pressure sensor
title_short Telemedicin enabled mobile pulse and blood pressure sensor
title_sort telemedicin enabled mobile pulse and blood pressure sensor
topic Other Electrical Engineering
Electronic Engineering
Information Engineering
Annan elektroteknik och elektronik
topic_facet Other Electrical Engineering
Electronic Engineering
Information Engineering
Annan elektroteknik och elektronik
url http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-25527