Non-destructive testing of a post-tensioned concrete road bridge in Norway

The Herøysunds bridge on the west-coast in Nordland Fylke in Norway had undergone concrete repair works with focus on reinforcement corrosion. During these actions, it was discovered that the tendon ducts had loss of injection. To ensure the safety of the bridge it was decided to map voids and defe...

Full description

Bibliographic Details
Main Authors: Täljsten, Björn, Popescu, C., Holmqvist, M.
Format: Conference Object
Language:English
Published: Luleå tekniska universitet, Byggkonstruktion och brand 2024
Subjects:
Online Access:http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644
https://doi.org/10.1201/9781003483755-462
id ftluleatu:oai:DiVA.org:ltu-108644
record_format openpolar
spelling ftluleatu:oai:DiVA.org:ltu-108644 2024-09-15T18:20:32+00:00 Non-destructive testing of a post-tensioned concrete road bridge in Norway Täljsten, Björn Popescu, C. Holmqvist, M. 2024 application/pdf http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644 https://doi.org/10.1201/9781003483755-462 eng eng LuleÃ¥ tekniska universitet, Byggkonstruktion och brand Invator AB, Sweden Sintef AS and Invator AB, Sweden Bridge Maintenance, Safety, Management, Digitalization and Sustainability, p. 3913-3921 orcid:0000-0001-7799-5809 http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644 doi:10.1201/9781003483755-462 Scopus 2-s2.0-85200351935 info:eu-repo/semantics/openAccess Infrastructure Engineering Infrastrukturteknik Conference paper info:eu-repo/semantics/conferenceObject text 2024 ftluleatu https://doi.org/10.1201/9781003483755-462 2024-08-20T23:39:29Z The Herøysunds bridge on the west-coast in Nordland Fylke in Norway had undergone concrete repair works with focus on reinforcement corrosion. During these actions, it was discovered that the tendon ducts had loss of injection. To ensure the safety of the bridge it was decided to map voids and defects in the ducts. Several risk areas were pointed out by the constructor and a non-destructive test (NDT) was carried out. A methodology with combin-ation of different NDT methods were used; cover meter, GPR, UPE, IE and Videoscope. The results from the NDT investigate shows that the suggested approach was successful, and it was possible with high accuracy to detect voids in the ducts. The methodology forms a basis for the procedure recommended by the Norwegian Public Roads Administration. Funder: Norwegian public road administration; Nordland municipality; Full text license: CC BY-NC-ND; ISBN for host publication: 9781003483755; Conference Object Nordland Nordland Nordland Luleå University of Technology Publications (DiVA) 3913 3921 London
institution Open Polar
collection Luleå University of Technology Publications (DiVA)
op_collection_id ftluleatu
language English
topic Infrastructure Engineering
Infrastrukturteknik
spellingShingle Infrastructure Engineering
Infrastrukturteknik
Täljsten, Björn
Popescu, C.
Holmqvist, M.
Non-destructive testing of a post-tensioned concrete road bridge in Norway
topic_facet Infrastructure Engineering
Infrastrukturteknik
description The Herøysunds bridge on the west-coast in Nordland Fylke in Norway had undergone concrete repair works with focus on reinforcement corrosion. During these actions, it was discovered that the tendon ducts had loss of injection. To ensure the safety of the bridge it was decided to map voids and defects in the ducts. Several risk areas were pointed out by the constructor and a non-destructive test (NDT) was carried out. A methodology with combin-ation of different NDT methods were used; cover meter, GPR, UPE, IE and Videoscope. The results from the NDT investigate shows that the suggested approach was successful, and it was possible with high accuracy to detect voids in the ducts. The methodology forms a basis for the procedure recommended by the Norwegian Public Roads Administration. Funder: Norwegian public road administration; Nordland municipality; Full text license: CC BY-NC-ND; ISBN for host publication: 9781003483755;
format Conference Object
author Täljsten, Björn
Popescu, C.
Holmqvist, M.
author_facet Täljsten, Björn
Popescu, C.
Holmqvist, M.
author_sort Täljsten, Björn
title Non-destructive testing of a post-tensioned concrete road bridge in Norway
title_short Non-destructive testing of a post-tensioned concrete road bridge in Norway
title_full Non-destructive testing of a post-tensioned concrete road bridge in Norway
title_fullStr Non-destructive testing of a post-tensioned concrete road bridge in Norway
title_full_unstemmed Non-destructive testing of a post-tensioned concrete road bridge in Norway
title_sort non-destructive testing of a post-tensioned concrete road bridge in norway
publisher Luleå tekniska universitet, Byggkonstruktion och brand
publishDate 2024
url http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644
https://doi.org/10.1201/9781003483755-462
genre Nordland
Nordland
Nordland
genre_facet Nordland
Nordland
Nordland
op_relation Bridge Maintenance, Safety, Management, Digitalization and Sustainability, p. 3913-3921
orcid:0000-0001-7799-5809
http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644
doi:10.1201/9781003483755-462
Scopus 2-s2.0-85200351935
op_rights info:eu-repo/semantics/openAccess
op_doi https://doi.org/10.1201/9781003483755-462
container_start_page 3913
op_container_end_page 3921
op_publisher_place London
_version_ 1810458918011273216