Non-destructive testing of a post-tensioned concrete road bridge in Norway
The Herøysunds bridge on the west-coast in Nordland Fylke in Norway had undergone concrete repair works with focus on reinforcement corrosion. During these actions, it was discovered that the tendon ducts had loss of injection. To ensure the safety of the bridge it was decided to map voids and defe...
Main Authors: | , , |
---|---|
Format: | Conference Object |
Language: | English |
Published: |
Luleå tekniska universitet, Byggkonstruktion och brand
2024
|
Subjects: | |
Online Access: | http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644 https://doi.org/10.1201/9781003483755-462 |
id |
ftluleatu:oai:DiVA.org:ltu-108644 |
---|---|
record_format |
openpolar |
spelling |
ftluleatu:oai:DiVA.org:ltu-108644 2024-09-15T18:20:32+00:00 Non-destructive testing of a post-tensioned concrete road bridge in Norway Täljsten, Björn Popescu, C. Holmqvist, M. 2024 application/pdf http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644 https://doi.org/10.1201/9781003483755-462 eng eng LuleÃ¥ tekniska universitet, Byggkonstruktion och brand Invator AB, Sweden Sintef AS and Invator AB, Sweden Bridge Maintenance, Safety, Management, Digitalization and Sustainability, p. 3913-3921 orcid:0000-0001-7799-5809 http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644 doi:10.1201/9781003483755-462 Scopus 2-s2.0-85200351935 info:eu-repo/semantics/openAccess Infrastructure Engineering Infrastrukturteknik Conference paper info:eu-repo/semantics/conferenceObject text 2024 ftluleatu https://doi.org/10.1201/9781003483755-462 2024-08-20T23:39:29Z The Herøysunds bridge on the west-coast in Nordland Fylke in Norway had undergone concrete repair works with focus on reinforcement corrosion. During these actions, it was discovered that the tendon ducts had loss of injection. To ensure the safety of the bridge it was decided to map voids and defects in the ducts. Several risk areas were pointed out by the constructor and a non-destructive test (NDT) was carried out. A methodology with combin-ation of different NDT methods were used; cover meter, GPR, UPE, IE and Videoscope. The results from the NDT investigate shows that the suggested approach was successful, and it was possible with high accuracy to detect voids in the ducts. The methodology forms a basis for the procedure recommended by the Norwegian Public Roads Administration. Funder: Norwegian public road administration; Nordland municipality; Full text license: CC BY-NC-ND; ISBN for host publication: 9781003483755; Conference Object Nordland Nordland Nordland Luleå University of Technology Publications (DiVA) 3913 3921 London |
institution |
Open Polar |
collection |
Luleå University of Technology Publications (DiVA) |
op_collection_id |
ftluleatu |
language |
English |
topic |
Infrastructure Engineering Infrastrukturteknik |
spellingShingle |
Infrastructure Engineering Infrastrukturteknik Täljsten, Björn Popescu, C. Holmqvist, M. Non-destructive testing of a post-tensioned concrete road bridge in Norway |
topic_facet |
Infrastructure Engineering Infrastrukturteknik |
description |
The Herøysunds bridge on the west-coast in Nordland Fylke in Norway had undergone concrete repair works with focus on reinforcement corrosion. During these actions, it was discovered that the tendon ducts had loss of injection. To ensure the safety of the bridge it was decided to map voids and defects in the ducts. Several risk areas were pointed out by the constructor and a non-destructive test (NDT) was carried out. A methodology with combin-ation of different NDT methods were used; cover meter, GPR, UPE, IE and Videoscope. The results from the NDT investigate shows that the suggested approach was successful, and it was possible with high accuracy to detect voids in the ducts. The methodology forms a basis for the procedure recommended by the Norwegian Public Roads Administration. Funder: Norwegian public road administration; Nordland municipality; Full text license: CC BY-NC-ND; ISBN for host publication: 9781003483755; |
format |
Conference Object |
author |
Täljsten, Björn Popescu, C. Holmqvist, M. |
author_facet |
Täljsten, Björn Popescu, C. Holmqvist, M. |
author_sort |
Täljsten, Björn |
title |
Non-destructive testing of a post-tensioned concrete road bridge in Norway |
title_short |
Non-destructive testing of a post-tensioned concrete road bridge in Norway |
title_full |
Non-destructive testing of a post-tensioned concrete road bridge in Norway |
title_fullStr |
Non-destructive testing of a post-tensioned concrete road bridge in Norway |
title_full_unstemmed |
Non-destructive testing of a post-tensioned concrete road bridge in Norway |
title_sort |
non-destructive testing of a post-tensioned concrete road bridge in norway |
publisher |
Luleå tekniska universitet, Byggkonstruktion och brand |
publishDate |
2024 |
url |
http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644 https://doi.org/10.1201/9781003483755-462 |
genre |
Nordland Nordland Nordland |
genre_facet |
Nordland Nordland Nordland |
op_relation |
Bridge Maintenance, Safety, Management, Digitalization and Sustainability, p. 3913-3921 orcid:0000-0001-7799-5809 http://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-108644 doi:10.1201/9781003483755-462 Scopus 2-s2.0-85200351935 |
op_rights |
info:eu-repo/semantics/openAccess |
op_doi |
https://doi.org/10.1201/9781003483755-462 |
container_start_page |
3913 |
op_container_end_page |
3921 |
op_publisher_place |
London |
_version_ |
1810458918011273216 |