Design and performance characteristics of a condensation particle counter UF-02proto

In this paper we present a design of a new swirling flow condensation particle counter UF-02proto, which has a continuous sampling flow. The performance and characteristics of the instrument were investigated. We studied experimentally the concentration range of the instrument and the detection effi...

Full description

Bibliographic Details
Main Authors: Mordas, Genrikas, Kulmala, Markku, Petäjä, Tuukka, Aalto, Pasi P., Matulevičius, Vytautas, Grigoraitis, Vytautas, Ulevičius, Vidmantas, Grauslys, Vaclovas, Ukkonen, Ari, Hämeri, Kaarle
Format: Article in Journal/Newspaper
Language:English
Published: 2005
Subjects:
Online Access:http://ftmc.lvb.lt/FTMC:ELABAPDB6072087&prefLang=en_US
id ftlithuaniansrc:oai:elaba:6072087
record_format openpolar
spelling ftlithuaniansrc:oai:elaba:6072087 2023-05-15T15:45:39+02:00 Design and performance characteristics of a condensation particle counter UF-02proto Mordas, Genrikas Kulmala, Markku Petäjä, Tuukka Aalto, Pasi P. Matulevičius, Vytautas Grigoraitis, Vytautas Ulevičius, Vidmantas Grauslys, Vaclovas Ukkonen, Ari Hämeri, Kaarle 2005 http://ftmc.lvb.lt/FTMC:ELABAPDB6072087&prefLang=en_US eng eng http://ftmc.lvb.lt/FTMC:ELABAPDB6072087&prefLang=en_US Boreal environment research, 2005, Vol. 10, no. 6, p. 543-552 ISSN 1239-6095 info:eu-repo/semantics/article 2005 ftlithuaniansrc 2021-12-02T00:38:19Z In this paper we present a design of a new swirling flow condensation particle counter UF-02proto, which has a continuous sampling flow. The performance and characteristics of the instrument were investigated. We studied experimentally the concentration range of the instrument and the detection efficiency as a function of particle diameter for silver particles. The lower cut-off size of the CPC, i.e. the limiting size when 50% of the particles are successfully accounted for, was determined to be 4.35–4.46 nm, depending slightly on a form of a fitted exponential step-function. The counting efficiency of the CPC at high particle concentrations was experimentally investigated using 20 nm silver particles. The maximum observable number concentration with a single particle counting method was approximately 100000 cm–3 with an accuracy of 20%. The operation of the CPC UF-02proto was also compared with that of a commercially available CPC when operating both instruments in parallel. The CPC proved to be suitable for a variety of applications with a wide range of particle concentrations and particle sizes. Article in Journal/Newspaper Boreal Environment Research LSRC VL (Lithuanian Social Research Centre Virtual Library)
institution Open Polar
collection LSRC VL (Lithuanian Social Research Centre Virtual Library)
op_collection_id ftlithuaniansrc
language English
description In this paper we present a design of a new swirling flow condensation particle counter UF-02proto, which has a continuous sampling flow. The performance and characteristics of the instrument were investigated. We studied experimentally the concentration range of the instrument and the detection efficiency as a function of particle diameter for silver particles. The lower cut-off size of the CPC, i.e. the limiting size when 50% of the particles are successfully accounted for, was determined to be 4.35–4.46 nm, depending slightly on a form of a fitted exponential step-function. The counting efficiency of the CPC at high particle concentrations was experimentally investigated using 20 nm silver particles. The maximum observable number concentration with a single particle counting method was approximately 100000 cm–3 with an accuracy of 20%. The operation of the CPC UF-02proto was also compared with that of a commercially available CPC when operating both instruments in parallel. The CPC proved to be suitable for a variety of applications with a wide range of particle concentrations and particle sizes.
format Article in Journal/Newspaper
author Mordas, Genrikas
Kulmala, Markku
Petäjä, Tuukka
Aalto, Pasi P.
Matulevičius, Vytautas
Grigoraitis, Vytautas
Ulevičius, Vidmantas
Grauslys, Vaclovas
Ukkonen, Ari
Hämeri, Kaarle
spellingShingle Mordas, Genrikas
Kulmala, Markku
Petäjä, Tuukka
Aalto, Pasi P.
Matulevičius, Vytautas
Grigoraitis, Vytautas
Ulevičius, Vidmantas
Grauslys, Vaclovas
Ukkonen, Ari
Hämeri, Kaarle
Design and performance characteristics of a condensation particle counter UF-02proto
author_facet Mordas, Genrikas
Kulmala, Markku
Petäjä, Tuukka
Aalto, Pasi P.
Matulevičius, Vytautas
Grigoraitis, Vytautas
Ulevičius, Vidmantas
Grauslys, Vaclovas
Ukkonen, Ari
Hämeri, Kaarle
author_sort Mordas, Genrikas
title Design and performance characteristics of a condensation particle counter UF-02proto
title_short Design and performance characteristics of a condensation particle counter UF-02proto
title_full Design and performance characteristics of a condensation particle counter UF-02proto
title_fullStr Design and performance characteristics of a condensation particle counter UF-02proto
title_full_unstemmed Design and performance characteristics of a condensation particle counter UF-02proto
title_sort design and performance characteristics of a condensation particle counter uf-02proto
publishDate 2005
url http://ftmc.lvb.lt/FTMC:ELABAPDB6072087&prefLang=en_US
genre Boreal Environment Research
genre_facet Boreal Environment Research
op_source Boreal environment research, 2005, Vol. 10, no. 6, p. 543-552
ISSN 1239-6095
op_relation http://ftmc.lvb.lt/FTMC:ELABAPDB6072087&prefLang=en_US
_version_ 1766380158927765504