Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients
To access publisher full text version of this article. Please click on the hyperlink in Additional Links field AIMS: Studies indicate a poorer quality of life (QoL) for implantable cardioverter defibrillator (ICD) patients than for the general population. However, studies comparing the QoL of ICD pa...
Published in: | EP Europace |
---|---|
Main Authors: | , , , , , , , |
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
Oxford University Press
2006
|
Subjects: | |
Online Access: | http://hdl.handle.net/2336/6532 https://doi.org/10.1093/europace/euj052 |
id |
ftlandspitaliuni:oai:www.hirsla.lsh.is:2336/6532 |
---|---|
record_format |
openpolar |
spelling |
ftlandspitaliuni:oai:www.hirsla.lsh.is:2336/6532 2023-05-15T16:51:12+02:00 Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients Leosdottir, Margret Sigurdsson, Engilbert Reimarsdottir, Gudrun Gottskalksson, Gizur Torfason, Bjarni Vigfusdottir, Margret Eggertsson, Sveinn Arnar, David O 2006-12-13 YES http://hdl.handle.net/2336/6532 https://doi.org/10.1093/europace/euj052 en eng Oxford University Press http://europace.oxfordjournals.org/cgi/content/abstract/8/3/168 Europace 2006, 8(3):168-74 1099-5129 16627433 doi:10.1093/europace/euj052 PSY12 CAR12 http://hdl.handle.net/2336/6532 Europace : European pacing, arrhythmias, and cardiac electrophysiology Adult Aged 80 and over Anxiety Defibrillators Implantable Depression Female Health Status Humans Male Middle Aged Pacemaker Artificial Quality of Life Questionnaires Stress Psychological Article 2006 ftlandspitaliuni https://doi.org/10.1093/europace/euj052 2022-05-29T08:20:55Z To access publisher full text version of this article. Please click on the hyperlink in Additional Links field AIMS: Studies indicate a poorer quality of life (QoL) for implantable cardioverter defibrillator (ICD) patients than for the general population. However, studies comparing the QoL of ICD patients with that of patients with other implantable cardiac devices are scarce. We hypothesized that ICD patients had a poorer QoL than pacemaker patients. METHODS AND RESULTS: All ICD patients living in Iceland at the beginning of 2002 (44 subjects), and a comparison group of 81 randomly selected patients with pacemakers were invited to participate. The Icelandic Quality of Life Questionnaire (IQL), the General Health Questionnaire (GHQ), the Beck Anxiety Inventory (BAI), and the Beck Depression Inventory (BDI) were submitted to measure QoL, psychiatric distress, and symptoms of anxiety and depression. The ICD and pacemaker groups did not differ on IQL, BAI, BDI, or GHQ scores. ICD patients were as a group more fearful of death (P = 0.056) and showed more concerns about returning to work (P = 0.072), although these items fell just short of statistical significance. CONCLUSION: Contrary to our expectations, ICD patients had a comparable QoL with pacemaker recipients and were not more likely to suffer from anxiety, depression, or general psychiatric distress. These findings are encouraging in view of expanding ICD indications. Article in Journal/Newspaper Iceland Hirsla - Landspítali University Hospital research archive Beck ENVELOPE(67.017,67.017,-71.033,-71.033) EP Europace 8 3 168 174 |
institution |
Open Polar |
collection |
Hirsla - Landspítali University Hospital research archive |
op_collection_id |
ftlandspitaliuni |
language |
English |
topic |
Adult Aged 80 and over Anxiety Defibrillators Implantable Depression Female Health Status Humans Male Middle Aged Pacemaker Artificial Quality of Life Questionnaires Stress Psychological |
spellingShingle |
Adult Aged 80 and over Anxiety Defibrillators Implantable Depression Female Health Status Humans Male Middle Aged Pacemaker Artificial Quality of Life Questionnaires Stress Psychological Leosdottir, Margret Sigurdsson, Engilbert Reimarsdottir, Gudrun Gottskalksson, Gizur Torfason, Bjarni Vigfusdottir, Margret Eggertsson, Sveinn Arnar, David O Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients |
topic_facet |
Adult Aged 80 and over Anxiety Defibrillators Implantable Depression Female Health Status Humans Male Middle Aged Pacemaker Artificial Quality of Life Questionnaires Stress Psychological |
description |
To access publisher full text version of this article. Please click on the hyperlink in Additional Links field AIMS: Studies indicate a poorer quality of life (QoL) for implantable cardioverter defibrillator (ICD) patients than for the general population. However, studies comparing the QoL of ICD patients with that of patients with other implantable cardiac devices are scarce. We hypothesized that ICD patients had a poorer QoL than pacemaker patients. METHODS AND RESULTS: All ICD patients living in Iceland at the beginning of 2002 (44 subjects), and a comparison group of 81 randomly selected patients with pacemakers were invited to participate. The Icelandic Quality of Life Questionnaire (IQL), the General Health Questionnaire (GHQ), the Beck Anxiety Inventory (BAI), and the Beck Depression Inventory (BDI) were submitted to measure QoL, psychiatric distress, and symptoms of anxiety and depression. The ICD and pacemaker groups did not differ on IQL, BAI, BDI, or GHQ scores. ICD patients were as a group more fearful of death (P = 0.056) and showed more concerns about returning to work (P = 0.072), although these items fell just short of statistical significance. CONCLUSION: Contrary to our expectations, ICD patients had a comparable QoL with pacemaker recipients and were not more likely to suffer from anxiety, depression, or general psychiatric distress. These findings are encouraging in view of expanding ICD indications. |
format |
Article in Journal/Newspaper |
author |
Leosdottir, Margret Sigurdsson, Engilbert Reimarsdottir, Gudrun Gottskalksson, Gizur Torfason, Bjarni Vigfusdottir, Margret Eggertsson, Sveinn Arnar, David O |
author_facet |
Leosdottir, Margret Sigurdsson, Engilbert Reimarsdottir, Gudrun Gottskalksson, Gizur Torfason, Bjarni Vigfusdottir, Margret Eggertsson, Sveinn Arnar, David O |
author_sort |
Leosdottir, Margret |
title |
Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients |
title_short |
Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients |
title_full |
Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients |
title_fullStr |
Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients |
title_full_unstemmed |
Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients |
title_sort |
health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients |
publisher |
Oxford University Press |
publishDate |
2006 |
url |
http://hdl.handle.net/2336/6532 https://doi.org/10.1093/europace/euj052 |
long_lat |
ENVELOPE(67.017,67.017,-71.033,-71.033) |
geographic |
Beck |
geographic_facet |
Beck |
genre |
Iceland |
genre_facet |
Iceland |
op_relation |
http://europace.oxfordjournals.org/cgi/content/abstract/8/3/168 Europace 2006, 8(3):168-74 1099-5129 16627433 doi:10.1093/europace/euj052 PSY12 CAR12 http://hdl.handle.net/2336/6532 Europace : European pacing, arrhythmias, and cardiac electrophysiology |
op_doi |
https://doi.org/10.1093/europace/euj052 |
container_title |
EP Europace |
container_volume |
8 |
container_issue |
3 |
container_start_page |
168 |
op_container_end_page |
174 |
_version_ |
1766041307021574144 |