Comparison of aneroid and oscillometric blood pressure measurements in children.

To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked Files. This article is open access. Limited data exist on the comparison of blood pressure (BP) measurements using aneroid and...

Full description

Bibliographic Details
Published in:The Journal of Clinical Hypertension
Main Authors: Eliasdottir, Sigridur B, Steinthorsdottir, Sandra D, Indridason, Olafur S, Palsson, Runolfur, Edvardsson, Vidar O
Other Authors: Univ Iceland, Sch Hlth Sci, Fac Med, Reykjavik, Iceland , Landspitali Natl Univ Hosp Iceland, Div Nephrol, Reykjavik, Iceland, Landspitali Natl Univ Hosp Iceland, Childrens Med Ctr, Reykjavik, Iceland
Format: Article in Journal/Newspaper
Language:English
Published: Wiley-Blackwell 2013
Subjects:
Online Access:http://hdl.handle.net/2336/324839
https://doi.org/10.1111/jch.12196
id ftlandspitaliuni:oai:www.hirsla.lsh.is:2336/324839
record_format openpolar
spelling ftlandspitaliuni:oai:www.hirsla.lsh.is:2336/324839 2023-05-15T16:50:41+02:00 Comparison of aneroid and oscillometric blood pressure measurements in children. Eliasdottir, Sigridur B Steinthorsdottir, Sandra D Indridason, Olafur S Palsson, Runolfur Edvardsson, Vidar O Univ Iceland, Sch Hlth Sci, Fac Med, Reykjavik, Iceland , Landspitali Natl Univ Hosp Iceland, Div Nephrol, Reykjavik, Iceland, Landspitali Natl Univ Hosp Iceland, Childrens Med Ctr, Reykjavik, Iceland 2013 http://hdl.handle.net/2336/324839 https://doi.org/10.1111/jch.12196 en eng Wiley-Blackwell http://dx.doi.org/10.1111/jch.12196 J Clin Hypertens (Greenwich) 2013, 15 (11):776-83 1751-7176 24112661 doi:10.1111/jch.12196 http://hdl.handle.net/2336/324839 Journal of clinical hypertension (Greenwich, Conn.) Archived with thanks to Journal of clinical hypertension (Greenwich, Conn.) National Consortium - Landsaðgangur Blóðþrýstingur Börn Oscillometry/instrumentation Blood Pressure Determination/methods Child Article 2013 ftlandspitaliuni https://doi.org/10.1111/jch.12196 2022-05-29T08:21:58Z To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked Files. This article is open access. Limited data exist on the comparison of blood pressure (BP) measurements using aneroid and oscillometric devices. The purpose of the study was to investigate the difference in BP obtained using oscillometric and aneroid BP monitors in 9- to 10-year-old children. A total of 979 children were divided into group O, which underwent two oscillometric BP readings followed by two aneroid readings, and group A, which had BP measured in the reverse order. No significant difference was found between the mean (±standard deviation) of the two systolic BP readings obtained using the oscillometric and aneroid devices (111.5±8.6 vs 111.3±8.1 mm Hg; P=.39), whereas the mean diastolic BP was lower with the oscillometric monitor (61.5±8.0 vs 64.5±6.8 mm Hg; P<.001). A significant downward trend in BP was observed with each consecutive measurement, and agreement between the two monitors was limited. Multiple BP measurements are, therefore, recommended before the diagnosis of elevated BP or hypertension is made with either method. Landspitali - The National University Hospital of Iceland Research Fund Article in Journal/Newspaper Iceland Hirsla - Landspítali University Hospital research archive The Journal of Clinical Hypertension 15 11 776 783
institution Open Polar
collection Hirsla - Landspítali University Hospital research archive
op_collection_id ftlandspitaliuni
language English
topic Blóðþrýstingur
Börn
Oscillometry/instrumentation
Blood Pressure Determination/methods
Child
spellingShingle Blóðþrýstingur
Börn
Oscillometry/instrumentation
Blood Pressure Determination/methods
Child
Eliasdottir, Sigridur B
Steinthorsdottir, Sandra D
Indridason, Olafur S
Palsson, Runolfur
Edvardsson, Vidar O
Comparison of aneroid and oscillometric blood pressure measurements in children.
topic_facet Blóðþrýstingur
Börn
Oscillometry/instrumentation
Blood Pressure Determination/methods
Child
description To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked Files. This article is open access. Limited data exist on the comparison of blood pressure (BP) measurements using aneroid and oscillometric devices. The purpose of the study was to investigate the difference in BP obtained using oscillometric and aneroid BP monitors in 9- to 10-year-old children. A total of 979 children were divided into group O, which underwent two oscillometric BP readings followed by two aneroid readings, and group A, which had BP measured in the reverse order. No significant difference was found between the mean (±standard deviation) of the two systolic BP readings obtained using the oscillometric and aneroid devices (111.5±8.6 vs 111.3±8.1 mm Hg; P=.39), whereas the mean diastolic BP was lower with the oscillometric monitor (61.5±8.0 vs 64.5±6.8 mm Hg; P<.001). A significant downward trend in BP was observed with each consecutive measurement, and agreement between the two monitors was limited. Multiple BP measurements are, therefore, recommended before the diagnosis of elevated BP or hypertension is made with either method. Landspitali - The National University Hospital of Iceland Research Fund
author2 Univ Iceland, Sch Hlth Sci, Fac Med, Reykjavik, Iceland , Landspitali Natl Univ Hosp Iceland, Div Nephrol, Reykjavik, Iceland, Landspitali Natl Univ Hosp Iceland, Childrens Med Ctr, Reykjavik, Iceland
format Article in Journal/Newspaper
author Eliasdottir, Sigridur B
Steinthorsdottir, Sandra D
Indridason, Olafur S
Palsson, Runolfur
Edvardsson, Vidar O
author_facet Eliasdottir, Sigridur B
Steinthorsdottir, Sandra D
Indridason, Olafur S
Palsson, Runolfur
Edvardsson, Vidar O
author_sort Eliasdottir, Sigridur B
title Comparison of aneroid and oscillometric blood pressure measurements in children.
title_short Comparison of aneroid and oscillometric blood pressure measurements in children.
title_full Comparison of aneroid and oscillometric blood pressure measurements in children.
title_fullStr Comparison of aneroid and oscillometric blood pressure measurements in children.
title_full_unstemmed Comparison of aneroid and oscillometric blood pressure measurements in children.
title_sort comparison of aneroid and oscillometric blood pressure measurements in children.
publisher Wiley-Blackwell
publishDate 2013
url http://hdl.handle.net/2336/324839
https://doi.org/10.1111/jch.12196
genre Iceland
genre_facet Iceland
op_relation http://dx.doi.org/10.1111/jch.12196
J Clin Hypertens (Greenwich) 2013, 15 (11):776-83
1751-7176
24112661
doi:10.1111/jch.12196
http://hdl.handle.net/2336/324839
Journal of clinical hypertension (Greenwich, Conn.)
op_rights Archived with thanks to Journal of clinical hypertension (Greenwich, Conn.)
National Consortium - Landsaðgangur
op_doi https://doi.org/10.1111/jch.12196
container_title The Journal of Clinical Hypertension
container_volume 15
container_issue 11
container_start_page 776
op_container_end_page 783
_version_ 1766040806859210752