PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN
The simulation of a chromatofocusing column for the separation of a model mixture of four proteins, sperm-whale myoglobin, horse myoglobin, transferrin, and albumin, was performed under transient pH gradients and by computer calculation with a differential model including the buffering action. A sim...
Published in: | Separation Science and Technology |
---|---|
Main Authors: | , , |
Format: | Article in Journal/Newspaper |
Language: | English |
Published: |
MARCEL DEKKER INC
1995
|
Subjects: | |
Online Access: | http://hdl.handle.net/10203/75514 https://doi.org/10.1080/01496399508013896 |
_version_ | 1829940351831375872 |
---|---|
author | CHUN, SW BAE, JY Kim, Jong-Duk |
author2 | Kim, Jong-Duk CHUN, SW BAE, JY |
author_facet | CHUN, SW BAE, JY Kim, Jong-Duk |
author_sort | CHUN, SW |
collection | Korea Advanced Institute of Science and Technology: KOASAS - KAIST Open Access Self-Archiving System |
container_issue | 10 |
container_start_page | 2101 |
container_title | Separation Science and Technology |
container_volume | 30 |
description | The simulation of a chromatofocusing column for the separation of a model mixture of four proteins, sperm-whale myoglobin, horse myoglobin, transferrin, and albumin, was performed under transient pH gradients and by computer calculation with a differential model including the buffering action. A simulated mixture of four proteins was eluted at the pH of their isoelectric points, and the internal elution pattern of horse myoglobin was visually determined. The focusing effect of protein by pH was illustrated with the elution of intermittent feeds into a single band. The smooth and linear pH gradients, having interaction with ion exchanger and mixed buffers, were produced by a differential model with a model buffer for the pH gradients and the protein elutions. The calculated linear pH gradients and elution profiles showed good agreements with experiments. The protein separation and focusing effect were calculated with a model buffer and the differential model. N |
format | Article in Journal/Newspaper |
genre | Sperm whale |
genre_facet | Sperm whale |
id | ftkoasas:oai:koasas.kaist.ac.kr:10203/75514 |
institution | Open Polar |
language | English |
op_collection_id | ftkoasas |
op_container_end_page | 2125 |
op_doi | https://doi.org/10.1080/01496399508013896 |
op_relation | http://hdl.handle.net/10203/75514 252 31136 A1995QZ17000001 doi:10.1080/01496399508013896 |
publishDate | 1995 |
publisher | MARCEL DEKKER INC |
record_format | openpolar |
spelling | ftkoasas:oai:koasas.kaist.ac.kr:10203/75514 2025-04-20T14:45:24+00:00 PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN CHUN, SW BAE, JY Kim, Jong-Duk Kim, Jong-Duk CHUN, SW BAE, JY 1995 http://hdl.handle.net/10203/75514 https://doi.org/10.1080/01496399508013896 English eng MARCEL DEKKER INC http://hdl.handle.net/10203/75514 252 31136 A1995QZ17000001 doi:10.1080/01496399508013896 ION-EXCHANGE COLUMNS EXPERIMENTAL-VERIFICATION CHROMATOGRAPHY SYSTEMS Article ART 1995 ftkoasas https://doi.org/10.1080/01496399508013896 2025-03-28T07:27:27Z The simulation of a chromatofocusing column for the separation of a model mixture of four proteins, sperm-whale myoglobin, horse myoglobin, transferrin, and albumin, was performed under transient pH gradients and by computer calculation with a differential model including the buffering action. A simulated mixture of four proteins was eluted at the pH of their isoelectric points, and the internal elution pattern of horse myoglobin was visually determined. The focusing effect of protein by pH was illustrated with the elution of intermittent feeds into a single band. The smooth and linear pH gradients, having interaction with ion exchanger and mixed buffers, were produced by a differential model with a model buffer for the pH gradients and the protein elutions. The calculated linear pH gradients and elution profiles showed good agreements with experiments. The protein separation and focusing effect were calculated with a model buffer and the differential model. N Article in Journal/Newspaper Sperm whale Korea Advanced Institute of Science and Technology: KOASAS - KAIST Open Access Self-Archiving System Separation Science and Technology 30 10 2101 2125 |
spellingShingle | ION-EXCHANGE COLUMNS EXPERIMENTAL-VERIFICATION CHROMATOGRAPHY SYSTEMS CHUN, SW BAE, JY Kim, Jong-Duk PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN |
title | PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN |
title_full | PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN |
title_fullStr | PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN |
title_full_unstemmed | PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN |
title_short | PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN |
title_sort | protein separation and focusing in a transient ph gradient column |
topic | ION-EXCHANGE COLUMNS EXPERIMENTAL-VERIFICATION CHROMATOGRAPHY SYSTEMS |
topic_facet | ION-EXCHANGE COLUMNS EXPERIMENTAL-VERIFICATION CHROMATOGRAPHY SYSTEMS |
url | http://hdl.handle.net/10203/75514 https://doi.org/10.1080/01496399508013896 |