PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN

The simulation of a chromatofocusing column for the separation of a model mixture of four proteins, sperm-whale myoglobin, horse myoglobin, transferrin, and albumin, was performed under transient pH gradients and by computer calculation with a differential model including the buffering action. A sim...

Full description

Bibliographic Details
Published in:Separation Science and Technology
Main Authors: CHUN, SW, BAE, JY, Kim, Jong-Duk
Format: Article in Journal/Newspaper
Language:English
Published: MARCEL DEKKER INC 1995
Subjects:
Online Access:http://hdl.handle.net/10203/75514
https://doi.org/10.1080/01496399508013896
_version_ 1829940351831375872
author CHUN, SW
BAE, JY
Kim, Jong-Duk
author2 Kim, Jong-Duk
CHUN, SW
BAE, JY
author_facet CHUN, SW
BAE, JY
Kim, Jong-Duk
author_sort CHUN, SW
collection Korea Advanced Institute of Science and Technology: KOASAS - KAIST Open Access Self-Archiving System
container_issue 10
container_start_page 2101
container_title Separation Science and Technology
container_volume 30
description The simulation of a chromatofocusing column for the separation of a model mixture of four proteins, sperm-whale myoglobin, horse myoglobin, transferrin, and albumin, was performed under transient pH gradients and by computer calculation with a differential model including the buffering action. A simulated mixture of four proteins was eluted at the pH of their isoelectric points, and the internal elution pattern of horse myoglobin was visually determined. The focusing effect of protein by pH was illustrated with the elution of intermittent feeds into a single band. The smooth and linear pH gradients, having interaction with ion exchanger and mixed buffers, were produced by a differential model with a model buffer for the pH gradients and the protein elutions. The calculated linear pH gradients and elution profiles showed good agreements with experiments. The protein separation and focusing effect were calculated with a model buffer and the differential model. N
format Article in Journal/Newspaper
genre Sperm whale
genre_facet Sperm whale
id ftkoasas:oai:koasas.kaist.ac.kr:10203/75514
institution Open Polar
language English
op_collection_id ftkoasas
op_container_end_page 2125
op_doi https://doi.org/10.1080/01496399508013896
op_relation http://hdl.handle.net/10203/75514
252
31136
A1995QZ17000001
doi:10.1080/01496399508013896
publishDate 1995
publisher MARCEL DEKKER INC
record_format openpolar
spelling ftkoasas:oai:koasas.kaist.ac.kr:10203/75514 2025-04-20T14:45:24+00:00 PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN CHUN, SW BAE, JY Kim, Jong-Duk Kim, Jong-Duk CHUN, SW BAE, JY 1995 http://hdl.handle.net/10203/75514 https://doi.org/10.1080/01496399508013896 English eng MARCEL DEKKER INC http://hdl.handle.net/10203/75514 252 31136 A1995QZ17000001 doi:10.1080/01496399508013896 ION-EXCHANGE COLUMNS EXPERIMENTAL-VERIFICATION CHROMATOGRAPHY SYSTEMS Article ART 1995 ftkoasas https://doi.org/10.1080/01496399508013896 2025-03-28T07:27:27Z The simulation of a chromatofocusing column for the separation of a model mixture of four proteins, sperm-whale myoglobin, horse myoglobin, transferrin, and albumin, was performed under transient pH gradients and by computer calculation with a differential model including the buffering action. A simulated mixture of four proteins was eluted at the pH of their isoelectric points, and the internal elution pattern of horse myoglobin was visually determined. The focusing effect of protein by pH was illustrated with the elution of intermittent feeds into a single band. The smooth and linear pH gradients, having interaction with ion exchanger and mixed buffers, were produced by a differential model with a model buffer for the pH gradients and the protein elutions. The calculated linear pH gradients and elution profiles showed good agreements with experiments. The protein separation and focusing effect were calculated with a model buffer and the differential model. N Article in Journal/Newspaper Sperm whale Korea Advanced Institute of Science and Technology: KOASAS - KAIST Open Access Self-Archiving System Separation Science and Technology 30 10 2101 2125
spellingShingle ION-EXCHANGE COLUMNS
EXPERIMENTAL-VERIFICATION
CHROMATOGRAPHY
SYSTEMS
CHUN, SW
BAE, JY
Kim, Jong-Duk
PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN
title PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN
title_full PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN
title_fullStr PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN
title_full_unstemmed PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN
title_short PROTEIN SEPARATION AND FOCUSING IN A TRANSIENT PH GRADIENT COLUMN
title_sort protein separation and focusing in a transient ph gradient column
topic ION-EXCHANGE COLUMNS
EXPERIMENTAL-VERIFICATION
CHROMATOGRAPHY
SYSTEMS
topic_facet ION-EXCHANGE COLUMNS
EXPERIMENTAL-VERIFICATION
CHROMATOGRAPHY
SYSTEMS
url http://hdl.handle.net/10203/75514
https://doi.org/10.1080/01496399508013896