Spatial variation of the total ozone column in Huancayo, Santiago de Chile and Antarctica during 2005-2020

The objective of this research is to determine the variation of the total ozone column over the regions of Huancayo, Santiago de Chile and Antarctica. The study focused on measurements of the total ozone column over Huancayo, Santiago de Chile and the Machupicchu Antarctic Research Station (ECAMP)....

Full description

Bibliographic Details
Published in:TAYACAJA
Main Authors: Angeles Suazo, Julio Miguel, Angeles Vasquez, Roberto, Suazo, Nataly, Navarro, Janette, Flores Rojas, Jose, Lavado, Carmencita, Abi Karam, Hugo
Format: Article in Journal/Newspaper
Language:Spanish
Published: Universidad Nacional Autónoma de Tayacaja Daniel Hernández Morillo 2022
Subjects:
OMI
Online Access:https://revistas.unat.edu.pe/index.php/RevTaya/article/view/200
https://doi.org/10.46908/tayacaja.v5i2.200
Description
Summary:The objective of this research is to determine the variation of the total ozone column over the regions of Huancayo, Santiago de Chile and Antarctica. The study focused on measurements of the total ozone column over Huancayo, Santiago de Chile and the Machupicchu Antarctic Research Station (ECAMP). Total column ozone data were obtained by NASA's Ozone Monitoring Instrument (OMI) over 16 years (2005-2020). Likewise, it was obtained that in Huancayo a monthly average of 243.1 Dobson Units (DU). In the Peruvian Antarctic station there is a monthly average of 276 DU. And, finally, the registered data obtained the minimum and maximum value of 237 (May) and 254 (September) respectively. Likewise, in Santiago de Chile the minimum and maximum value of 251 (March) and 301 (September) respectively were obtained. In Antarctica, the minimum and maximum value of 220 (September) and 310 (December) respectively were obtained. La presente investigación, tiene como objetivo, determinar la variación de la columna total de ozono sobre las regiones de Huancayo, Santiago de Chile y Antártica. El estudio se enfocó en las mediciones de la columna total de ozono sobre Huancayo, Santiago de Chile y la Estación Científica Antártica Machupicchu (ECAMP). Los datos de la columna de ozono total fueron obtenidos por el Ozone Monitoring Instrument (OMI) de la NASA durante 16 años (2005-2020). Asimismo, se obtuvo que en Huancayo un promedio mensual de 243.1 Unidades Dobson (UD). En la Estación Antártica Peruana se tiene un promedio mensual de 276 UD. Y, por último, los datos registrados se obtuvo el valor mínimo y máximo de 237(mayo) y 254 (setiembre) respectivamente. Asimismo, en Santiago de chile se obtuvo el valor mínimo y máximo de 251(marzo) y 301 (setiembre) respectivamente. En la Antártida se obtuvo el valor mínimo y máximo de 220(setiembre) y 310 (diciembre) respectivamente.