Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx)

This is the preprint version of the article. The original publication is available at www.springerlink.com Three lynx (Lynx lynx) were found dead following complications after a surgically implanted free floating intraperitoneal radio-transmitter became lodged within the pelvic canal. Two yearling l...

Full description

Bibliographic Details
Main Authors: Léchenne, Monique S., Bröjer, Caroline, Arnemo, Jon Martin, Andrén, Henrik, Ågren, Erik O.
Format: Article in Journal/Newspaper
Language:English
Published: Springer-Verlag Heidelberg 2012
Subjects:
Online Access:http://hdl.handle.net/11250/134472
http://dx.doi.org10.1007/s10344-011-0572-4
id fthshedmarkcom:oai:brage.bibsys.no:11250/134472
record_format openpolar
spelling fthshedmarkcom:oai:brage.bibsys.no:11250/134472 2023-05-15T18:50:20+02:00 Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx) Léchenne, Monique S. Bröjer, Caroline Arnemo, Jon Martin Andrén, Henrik Ågren, Erik O. 2012 http://hdl.handle.net/11250/134472 http://dx.doi.org10.1007/s10344-011-0572-4 eng eng Springer-Verlag Heidelberg 503-506 58 European Journal of Wildlife Research 2 implant lynx mortality radio-transmitter wildlife VDP::Mathematics and natural science: 400::Zoology and botany: 480 Journal article Peer reviewed 2012 fthshedmarkcom 2017-10-27T17:31:09Z This is the preprint version of the article. The original publication is available at www.springerlink.com Three lynx (Lynx lynx) were found dead following complications after a surgically implanted free floating intraperitoneal radio-transmitter became lodged within the pelvic canal. Two yearling lynx died due to consequences following severe constipation as the transmitter compressed the colon. Both were emaciated, with no abdominal or intrapelvic fat, which allowed the transmitter implant to fit into the pelvic canal. An adult female lynx died of dystocia when the pelvic birth canal was blocked by the transmitter when parturition began, leading to uterine rupture and subsequent peritonitis. A total of 41 lynx was implanted with this type of intraperitoneal transmitter in Scandinavia 1997-2002. After the three transmitter-associated mortalities, the transmitter type used in lynx cubs was exchanged for another model, and further fatalities due to the implants have not been documented. Article in Journal/Newspaper Lynx Lynx lynx lynx Inland Norway University of Applied Sciences: Brage INN
institution Open Polar
collection Inland Norway University of Applied Sciences: Brage INN
op_collection_id fthshedmarkcom
language English
topic implant
lynx
mortality
radio-transmitter
wildlife
VDP::Mathematics and natural science: 400::Zoology and botany: 480
spellingShingle implant
lynx
mortality
radio-transmitter
wildlife
VDP::Mathematics and natural science: 400::Zoology and botany: 480
Léchenne, Monique S.
Bröjer, Caroline
Arnemo, Jon Martin
Andrén, Henrik
Ågren, Erik O.
Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx)
topic_facet implant
lynx
mortality
radio-transmitter
wildlife
VDP::Mathematics and natural science: 400::Zoology and botany: 480
description This is the preprint version of the article. The original publication is available at www.springerlink.com Three lynx (Lynx lynx) were found dead following complications after a surgically implanted free floating intraperitoneal radio-transmitter became lodged within the pelvic canal. Two yearling lynx died due to consequences following severe constipation as the transmitter compressed the colon. Both were emaciated, with no abdominal or intrapelvic fat, which allowed the transmitter implant to fit into the pelvic canal. An adult female lynx died of dystocia when the pelvic birth canal was blocked by the transmitter when parturition began, leading to uterine rupture and subsequent peritonitis. A total of 41 lynx was implanted with this type of intraperitoneal transmitter in Scandinavia 1997-2002. After the three transmitter-associated mortalities, the transmitter type used in lynx cubs was exchanged for another model, and further fatalities due to the implants have not been documented.
format Article in Journal/Newspaper
author Léchenne, Monique S.
Bröjer, Caroline
Arnemo, Jon Martin
Andrén, Henrik
Ågren, Erik O.
author_facet Léchenne, Monique S.
Bröjer, Caroline
Arnemo, Jon Martin
Andrén, Henrik
Ågren, Erik O.
author_sort Léchenne, Monique S.
title Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx)
title_short Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx)
title_full Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx)
title_fullStr Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx)
title_full_unstemmed Mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in Eurasian lynx (Lynx lynx)
title_sort mortalities due to constipation and dystocia caused by intraperitoneal radio- transmitters in eurasian lynx (lynx lynx)
publisher Springer-Verlag Heidelberg
publishDate 2012
url http://hdl.handle.net/11250/134472
http://dx.doi.org10.1007/s10344-011-0572-4
genre Lynx
Lynx lynx lynx
genre_facet Lynx
Lynx lynx lynx
op_source 503-506
58
European Journal of Wildlife Research
2
_version_ 1766244051138379776