Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems

Introduction: Cryoballoon ablation is safe and secure for pulmonary vein isolation (PVI) in atrial fibrillation (AF). A novel system POLARx (Px), similar to Arctic Front Advance (AFA) has recently been marketed. We compared per-operative settings and non-fluoroscopic methods to evaluate pulmonary ve...

Full description

Bibliographic Details
Main Author: Metais, Denis
Other Authors: Université de Caen Normandie - UFR Santé (UNICAEN Santé), Université de Caen Normandie (UNICAEN), Normandie Université (NU)-Normandie Université (NU), Laure Champ-Rigot
Format: Master Thesis
Language:French
Published: HAL CCSD 2021
Subjects:
Online Access:https://dumas.ccsd.cnrs.fr/dumas-03552544
https://dumas.ccsd.cnrs.fr/dumas-03552544/document
https://dumas.ccsd.cnrs.fr/dumas-03552544/file/METAIS%20Denis.pdf
id ftdumashal:oai:HAL:dumas-03552544v1
record_format openpolar
spelling ftdumashal:oai:HAL:dumas-03552544v1 2023-07-30T04:02:13+02:00 Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems Indicateurs biophysiques per-opératoires et méthodes d’évaluation de l’occlusion veineuse pulmonaire sans fluoroscopie lors de l’ablation de fibrillation atriale par cryothérapie : comparaison entre deux systèmes de cryoablation Metais, Denis Université de Caen Normandie - UFR Santé (UNICAEN Santé) Université de Caen Normandie (UNICAEN) Normandie Université (NU)-Normandie Université (NU) Laure Champ-Rigot 2021-09-29 https://dumas.ccsd.cnrs.fr/dumas-03552544 https://dumas.ccsd.cnrs.fr/dumas-03552544/document https://dumas.ccsd.cnrs.fr/dumas-03552544/file/METAIS%20Denis.pdf fr fre HAL CCSD dumas-03552544 https://dumas.ccsd.cnrs.fr/dumas-03552544 https://dumas.ccsd.cnrs.fr/dumas-03552544/document https://dumas.ccsd.cnrs.fr/dumas-03552544/file/METAIS%20Denis.pdf info:eu-repo/semantics/OpenAccess https://dumas.ccsd.cnrs.fr/dumas-03552544 Médecine humaine et pathologie. 2021 Fibrillation auriculaire Ablation percutanée Cryothérapie Veines pulmonaires -- Maladies [SDV.MHEP]Life Sciences [q-bio]/Human health and pathology [SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular system info:eu-repo/semantics/masterThesis Master thesis 2021 ftdumashal 2023-07-20T20:24:38Z Introduction: Cryoballoon ablation is safe and secure for pulmonary vein isolation (PVI) in atrial fibrillation (AF). A novel system POLARx (Px), similar to Arctic Front Advance (AFA) has recently been marketed. We compared per-operative settings and non-fluoroscopic methods to evaluate pulmonary vein occlusion between both systems. Methods: 80 patients who underwent first-time cryoballoon ablation, were included consecutively in our study (Px=41, AFA=39). Results: Procedure and fluoroscopy durations were higher with Px. Cryoablation with Px was associated with lower nadir temperature (-57°C vs. -50°C, p<0.001) and longer thawing time (48s vs. 40s, p=0.037). Pulmonary veins potentials were recorded more often with Px. Time to Isolation was shorter with AFA but the rate of PVI whitin 60 seconds were similar in both groups. One-shot PVI was associated with lower temperature at 30sec, lower nadir temperature, longer thawing time, higher dPV and higher drop of ETCO2. The best cutoff value of dPV and dETCO2 for predicting one-shot PVI were 6.8 mmHg and 2.75 mmHg respectively. In the AFA group, dPV was associated with one-shot PVI (OR=1.23, p=0.026). In the Px group, there was no difference of dPV and ETCO2 between one-shot PVI and more than one-shot PVI. Px system was similar in acute efficacity after a learning curve. Conclusion: Px system has slightly different technical characteristics, with acute efficacity and safety similar to AFA. Non-fluoroscopic methods to assess pulmonary vein occlusion with either PVP or ETCO2 were associated with one-shot PVI, especially with AFA system. Introduction : la cryoablation est une technique sûre et efficace pour l’isolation des veines pulmonaires (IVP) chez les patients en fibrillation atriale (FA). Le nouveau système POLARx (Px) fonctionne sur le même principe général que l’Arctic Front Advance (AFA). Nous avons comparé les différents paramètres per-opératoires et les méthodes d’évaluation de l’occlusion veineuse pulmonaire sans fluoroscopie entre ces deux systèmes. ... Master Thesis Arctic Human health DUMAS (Dépôt Universitaire de Mémoires Après Soutenance) Arctic
institution Open Polar
collection DUMAS (Dépôt Universitaire de Mémoires Après Soutenance)
op_collection_id ftdumashal
language French
topic Fibrillation auriculaire
Ablation percutanée
Cryothérapie
Veines pulmonaires -- Maladies
[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular system
spellingShingle Fibrillation auriculaire
Ablation percutanée
Cryothérapie
Veines pulmonaires -- Maladies
[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular system
Metais, Denis
Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems
topic_facet Fibrillation auriculaire
Ablation percutanée
Cryothérapie
Veines pulmonaires -- Maladies
[SDV.MHEP]Life Sciences [q-bio]/Human health and pathology
[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular system
description Introduction: Cryoballoon ablation is safe and secure for pulmonary vein isolation (PVI) in atrial fibrillation (AF). A novel system POLARx (Px), similar to Arctic Front Advance (AFA) has recently been marketed. We compared per-operative settings and non-fluoroscopic methods to evaluate pulmonary vein occlusion between both systems. Methods: 80 patients who underwent first-time cryoballoon ablation, were included consecutively in our study (Px=41, AFA=39). Results: Procedure and fluoroscopy durations were higher with Px. Cryoablation with Px was associated with lower nadir temperature (-57°C vs. -50°C, p<0.001) and longer thawing time (48s vs. 40s, p=0.037). Pulmonary veins potentials were recorded more often with Px. Time to Isolation was shorter with AFA but the rate of PVI whitin 60 seconds were similar in both groups. One-shot PVI was associated with lower temperature at 30sec, lower nadir temperature, longer thawing time, higher dPV and higher drop of ETCO2. The best cutoff value of dPV and dETCO2 for predicting one-shot PVI were 6.8 mmHg and 2.75 mmHg respectively. In the AFA group, dPV was associated with one-shot PVI (OR=1.23, p=0.026). In the Px group, there was no difference of dPV and ETCO2 between one-shot PVI and more than one-shot PVI. Px system was similar in acute efficacity after a learning curve. Conclusion: Px system has slightly different technical characteristics, with acute efficacity and safety similar to AFA. Non-fluoroscopic methods to assess pulmonary vein occlusion with either PVP or ETCO2 were associated with one-shot PVI, especially with AFA system. Introduction : la cryoablation est une technique sûre et efficace pour l’isolation des veines pulmonaires (IVP) chez les patients en fibrillation atriale (FA). Le nouveau système POLARx (Px) fonctionne sur le même principe général que l’Arctic Front Advance (AFA). Nous avons comparé les différents paramètres per-opératoires et les méthodes d’évaluation de l’occlusion veineuse pulmonaire sans fluoroscopie entre ces deux systèmes. ...
author2 Université de Caen Normandie - UFR Santé (UNICAEN Santé)
Université de Caen Normandie (UNICAEN)
Normandie Université (NU)-Normandie Université (NU)
Laure Champ-Rigot
format Master Thesis
author Metais, Denis
author_facet Metais, Denis
author_sort Metais, Denis
title Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems
title_short Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems
title_full Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems
title_fullStr Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems
title_full_unstemmed Per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems
title_sort per-operative biophysicals settings and non-fluoroscopic assessment methods of pulmonary vein occlusion during cryoballoon ablation of atrial fibrillation: comparison between two systems
publisher HAL CCSD
publishDate 2021
url https://dumas.ccsd.cnrs.fr/dumas-03552544
https://dumas.ccsd.cnrs.fr/dumas-03552544/document
https://dumas.ccsd.cnrs.fr/dumas-03552544/file/METAIS%20Denis.pdf
geographic Arctic
geographic_facet Arctic
genre Arctic
Human health
genre_facet Arctic
Human health
op_source https://dumas.ccsd.cnrs.fr/dumas-03552544
Médecine humaine et pathologie. 2021
op_relation dumas-03552544
https://dumas.ccsd.cnrs.fr/dumas-03552544
https://dumas.ccsd.cnrs.fr/dumas-03552544/document
https://dumas.ccsd.cnrs.fr/dumas-03552544/file/METAIS%20Denis.pdf
op_rights info:eu-repo/semantics/OpenAccess
_version_ 1772812945499095040