Low-energy house in Sisimiut - Measurement equipment
This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit...
Main Authors: | , , |
---|---|
Format: | Book |
Language: | English |
Published: |
Technical University of Denmark
2013
|
Subjects: | |
Online Access: | https://orbit.dtu.dk/en/publications/75b2f06a-86f5-4a34-b0fc-b31f0b70cbaa https://backend.orbit.dtu.dk/ws/files/58804177/tr13_17_Delff_P_1.pdf |
id |
ftdtupubl:oai:pure.atira.dk:publications/75b2f06a-86f5-4a34-b0fc-b31f0b70cbaa |
---|---|
record_format |
openpolar |
spelling |
ftdtupubl:oai:pure.atira.dk:publications/75b2f06a-86f5-4a34-b0fc-b31f0b70cbaa 2023-05-15T16:29:13+02:00 Low-energy house in Sisimiut - Measurement equipment Andersen, Philip Hvidthøft Delff Rode, Carsten Madsen, Henrik 2013 application/pdf https://orbit.dtu.dk/en/publications/75b2f06a-86f5-4a34-b0fc-b31f0b70cbaa https://backend.orbit.dtu.dk/ws/files/58804177/tr13_17_Delff_P_1.pdf eng eng Technical University of Denmark info:eu-repo/semantics/openAccess Andersen , P H D , Rode , C & Madsen , H 2013 , Low-energy house in Sisimiut - Measurement equipment . DTU Compute Technical Report-2013 , no. 17 , Technical University of Denmark , Kgs. Lyngby . /dk/atira/pure/sustainabledevelopmentgoals/affordable_and_clean_energy SDG 7 - Affordable and Clean Energy /dk/atira/pure/sustainabledevelopmentgoals/climate_action SDG 13 - Climate Action book 2013 ftdtupubl 2022-08-14T08:15:51Z This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit, experiments can be designed in order to study heat dynamics of the building. It is described how to plan and execute such experiments in one apartment in the building. The building also features both a solar thermal system and extra buffer tank facilitating testing of storage strategies on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented to fetch and prepare the data for time series analysis. Examples are given on the use of these. Book Greenland Sisimiut Technical University of Denmark: DTU Orbit Greenland Sisimiut ENVELOPE(-53.674,-53.674,66.939,66.939) |
institution |
Open Polar |
collection |
Technical University of Denmark: DTU Orbit |
op_collection_id |
ftdtupubl |
language |
English |
topic |
/dk/atira/pure/sustainabledevelopmentgoals/affordable_and_clean_energy SDG 7 - Affordable and Clean Energy /dk/atira/pure/sustainabledevelopmentgoals/climate_action SDG 13 - Climate Action |
spellingShingle |
/dk/atira/pure/sustainabledevelopmentgoals/affordable_and_clean_energy SDG 7 - Affordable and Clean Energy /dk/atira/pure/sustainabledevelopmentgoals/climate_action SDG 13 - Climate Action Andersen, Philip Hvidthøft Delff Rode, Carsten Madsen, Henrik Low-energy house in Sisimiut - Measurement equipment |
topic_facet |
/dk/atira/pure/sustainabledevelopmentgoals/affordable_and_clean_energy SDG 7 - Affordable and Clean Energy /dk/atira/pure/sustainabledevelopmentgoals/climate_action SDG 13 - Climate Action |
description |
This paper documents the measurement equipment in a low-energy house in Sisimiut, Greenland. Detailed measurements are being taken on energy consumption, indoor temperatures, floor heating, ventilation, open/closed state of doors and windows, and indoors climate. Equipped with a central control unit, experiments can be designed in order to study heat dynamics of the building. It is described how to plan and execute such experiments in one apartment in the building. The building also features both a solar thermal system and extra buffer tank facilitating testing of storage strategies on the power generated by the solar thermal system. A weather station equipped with thermometer, pyranometer and anemometer is installed on the building as well. Finally, it is described how to retrieve data from an SQL server which is configured to take monthly backups. R functions have been implemented to fetch and prepare the data for time series analysis. Examples are given on the use of these. |
format |
Book |
author |
Andersen, Philip Hvidthøft Delff Rode, Carsten Madsen, Henrik |
author_facet |
Andersen, Philip Hvidthøft Delff Rode, Carsten Madsen, Henrik |
author_sort |
Andersen, Philip Hvidthøft Delff |
title |
Low-energy house in Sisimiut - Measurement equipment |
title_short |
Low-energy house in Sisimiut - Measurement equipment |
title_full |
Low-energy house in Sisimiut - Measurement equipment |
title_fullStr |
Low-energy house in Sisimiut - Measurement equipment |
title_full_unstemmed |
Low-energy house in Sisimiut - Measurement equipment |
title_sort |
low-energy house in sisimiut - measurement equipment |
publisher |
Technical University of Denmark |
publishDate |
2013 |
url |
https://orbit.dtu.dk/en/publications/75b2f06a-86f5-4a34-b0fc-b31f0b70cbaa https://backend.orbit.dtu.dk/ws/files/58804177/tr13_17_Delff_P_1.pdf |
long_lat |
ENVELOPE(-53.674,-53.674,66.939,66.939) |
geographic |
Greenland Sisimiut |
geographic_facet |
Greenland Sisimiut |
genre |
Greenland Sisimiut |
genre_facet |
Greenland Sisimiut |
op_source |
Andersen , P H D , Rode , C & Madsen , H 2013 , Low-energy house in Sisimiut - Measurement equipment . DTU Compute Technical Report-2013 , no. 17 , Technical University of Denmark , Kgs. Lyngby . |
op_rights |
info:eu-repo/semantics/openAccess |
_version_ |
1766018908148465664 |