Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model

Simulation of ultrasound images based on computed tomography (CT) data has previously been performed with different approaches. Shadow effects are normally pronounced in ultrasound images, so they should be included in the simulation. In this study, a method to capture the shadow effects has been de...

Full description

Bibliographic Details
Published in:The Journal of the Acoustical Society of America
Main Authors: Pham, An Hoai, Lundgren, Bo, Stage, Bjarne, Pedersen, Mads Møller, Hemmsen, Martin Christian, Nielsen, Michael Bachmann, Jensen, Jørgen Arendt
Format: Article in Journal/Newspaper
Language:English
Published: 2012
Subjects:
Online Access:https://orbit.dtu.dk/en/publications/2f35058c-b450-4c25-b98c-7db353c251bd
https://doi.org/10.1121/1.4726031
id ftdtupubl:oai:pure.atira.dk:publications/2f35058c-b450-4c25-b98c-7db353c251bd
record_format openpolar
spelling ftdtupubl:oai:pure.atira.dk:publications/2f35058c-b450-4c25-b98c-7db353c251bd 2024-04-28T08:19:32+00:00 Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model Pham, An Hoai Lundgren, Bo Stage, Bjarne Pedersen, Mads Møller Hemmsen, Martin Christian Nielsen, Michael Bachmann Jensen, Jørgen Arendt 2012 https://orbit.dtu.dk/en/publications/2f35058c-b450-4c25-b98c-7db353c251bd https://doi.org/10.1121/1.4726031 eng eng https://orbit.dtu.dk/en/publications/2f35058c-b450-4c25-b98c-7db353c251bd info:eu-repo/semantics/closedAccess Pham , A H , Lundgren , B , Stage , B , Pedersen , M M , Hemmsen , M C , Nielsen , M B & Jensen , J A 2012 , ' Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model ' , Acoustical Society of America. Journal , vol. 132 , no. 1 , pp. 487-497 . https://doi.org/10.1121/1.4726031 article 2012 ftdtupubl https://doi.org/10.1121/1.4726031 2024-04-03T15:04:39Z Simulation of ultrasound images based on computed tomography (CT) data has previously been performed with different approaches. Shadow effects are normally pronounced in ultrasound images, so they should be included in the simulation. In this study, a method to capture the shadow effects has been developed, which makes the simulated ultrasound images appear more realistic. The method using a focused beam tracing model gives diffuse shadows that are similar to the ones observed in measurements on real objects. Ultrasound images of a cod (Gadus morhua) were obtained with a BK Medical 2202 ProFocus ultrasound scanner (BK Medical, Herlev, Denmark) equipped with a dedicated research interface giving access to beamformed radio frequency data. CT images were obtained with an Aquilion ONE Toshiba CT scanner (Toshiba Medical Systems Corp., Tochigi, Japan). CT data were mapped from Hounsfield units to backscatter strength, attenuation coefficients, and characteristic acoustic impedance. The focused beam tracing model was used to create maps of the transmission coefficient and scattering strength maps. FIELD II was then used to simulate an ultrasound image of 38.955.34.5 mm, using 106 point scatterers. As there is no quantitative method to assess quality of a simulated ultrasound image compared to a measured one, visual inspection was used for evaluation Article in Journal/Newspaper Gadus morhua Technical University of Denmark: DTU Orbit The Journal of the Acoustical Society of America 132 1 487 497
institution Open Polar
collection Technical University of Denmark: DTU Orbit
op_collection_id ftdtupubl
language English
description Simulation of ultrasound images based on computed tomography (CT) data has previously been performed with different approaches. Shadow effects are normally pronounced in ultrasound images, so they should be included in the simulation. In this study, a method to capture the shadow effects has been developed, which makes the simulated ultrasound images appear more realistic. The method using a focused beam tracing model gives diffuse shadows that are similar to the ones observed in measurements on real objects. Ultrasound images of a cod (Gadus morhua) were obtained with a BK Medical 2202 ProFocus ultrasound scanner (BK Medical, Herlev, Denmark) equipped with a dedicated research interface giving access to beamformed radio frequency data. CT images were obtained with an Aquilion ONE Toshiba CT scanner (Toshiba Medical Systems Corp., Tochigi, Japan). CT data were mapped from Hounsfield units to backscatter strength, attenuation coefficients, and characteristic acoustic impedance. The focused beam tracing model was used to create maps of the transmission coefficient and scattering strength maps. FIELD II was then used to simulate an ultrasound image of 38.955.34.5 mm, using 106 point scatterers. As there is no quantitative method to assess quality of a simulated ultrasound image compared to a measured one, visual inspection was used for evaluation
format Article in Journal/Newspaper
author Pham, An Hoai
Lundgren, Bo
Stage, Bjarne
Pedersen, Mads Møller
Hemmsen, Martin Christian
Nielsen, Michael Bachmann
Jensen, Jørgen Arendt
spellingShingle Pham, An Hoai
Lundgren, Bo
Stage, Bjarne
Pedersen, Mads Møller
Hemmsen, Martin Christian
Nielsen, Michael Bachmann
Jensen, Jørgen Arendt
Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model
author_facet Pham, An Hoai
Lundgren, Bo
Stage, Bjarne
Pedersen, Mads Møller
Hemmsen, Martin Christian
Nielsen, Michael Bachmann
Jensen, Jørgen Arendt
author_sort Pham, An Hoai
title Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model
title_short Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model
title_full Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model
title_fullStr Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model
title_full_unstemmed Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model
title_sort shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model
publishDate 2012
url https://orbit.dtu.dk/en/publications/2f35058c-b450-4c25-b98c-7db353c251bd
https://doi.org/10.1121/1.4726031
genre Gadus morhua
genre_facet Gadus morhua
op_source Pham , A H , Lundgren , B , Stage , B , Pedersen , M M , Hemmsen , M C , Nielsen , M B & Jensen , J A 2012 , ' Shadow effects in simulated ultrasound images derived from computed tomography images using a focused beam tracing model ' , Acoustical Society of America. Journal , vol. 132 , no. 1 , pp. 487-497 . https://doi.org/10.1121/1.4726031
op_relation https://orbit.dtu.dk/en/publications/2f35058c-b450-4c25-b98c-7db353c251bd
op_rights info:eu-repo/semantics/closedAccess
op_doi https://doi.org/10.1121/1.4726031
container_title The Journal of the Acoustical Society of America
container_volume 132
container_issue 1
container_start_page 487
op_container_end_page 497
_version_ 1797582989798932480