A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment

Instead of a hydrogen maser, a carefully selected Crystal oscillator which is phase locked to a Cesium (Cs) frequency standard for time range of more than 100 seconds is adopted to the time and frequency standard of a geodetic VLBI experiment. The domestic VLBI experiment with 55km baseline using th...

Full description

Bibliographic Details
Main Authors: Kiuchi, Hitoshi, Amagai, Jun
Other Authors: COMMUNICATIONS RESEARCH LAB TOKYO (JAPAN)
Format: Text
Language:English
Published: 1990
Subjects:
Online Access:http://www.dtic.mil/docs/citations/ADA519486
http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA519486
id ftdtic:ADA519486
record_format openpolar
spelling ftdtic:ADA519486 2023-05-15T13:48:25+02:00 A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment Kiuchi, Hitoshi Amagai, Jun COMMUNICATIONS RESEARCH LAB TOKYO (JAPAN) 1990-12 text/html http://www.dtic.mil/docs/citations/ADA519486 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA519486 en eng http://www.dtic.mil/docs/citations/ADA519486 Approved for public release; distribution is unlimited. DTIC Lasers and Masers *MASERS CESIUM RANGE FINDING CRYSTAL OSCILLATORS PHASE LOCKED SYSTEMS FREQUENCY STANDARDS STABILITY Text 1990 ftdtic 2016-02-23T00:53:47Z Instead of a hydrogen maser, a carefully selected Crystal oscillator which is phase locked to a Cesium (Cs) frequency standard for time range of more than 100 seconds is adopted to the time and frequency standard of a geodetic VLBI experiment. The domestic VLBI experiment with 55km baseline using the Crystal oscillator at one end was made in Japan and the obtained error of the baseline vector components were 4cm, and that of the baseline length was 3cm. This system may be operated after only 2 hours warm up. These results coincides with those of conventional geodetic Laser ranging and VLBI using a hydrogen maser within the formal error. A VLBI experiment with over 1000km baselines were carried out successfully from October 1988, and over 11000km baseline bctween Japan and Antarctica was carried out succcssfully in January 1990. See also ADA239372. Presented at the Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting (22nd) held in Vienna, VA on 4-6 December 1990. Published in the Proceedings of the Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting (22nd), p131-143, December 1990. Text Antarc* Antarctica Defense Technical Information Center: DTIC Technical Reports database
institution Open Polar
collection Defense Technical Information Center: DTIC Technical Reports database
op_collection_id ftdtic
language English
topic Lasers and Masers
*MASERS
CESIUM
RANGE FINDING
CRYSTAL OSCILLATORS
PHASE LOCKED SYSTEMS
FREQUENCY STANDARDS
STABILITY
spellingShingle Lasers and Masers
*MASERS
CESIUM
RANGE FINDING
CRYSTAL OSCILLATORS
PHASE LOCKED SYSTEMS
FREQUENCY STANDARDS
STABILITY
Kiuchi, Hitoshi
Amagai, Jun
A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment
topic_facet Lasers and Masers
*MASERS
CESIUM
RANGE FINDING
CRYSTAL OSCILLATORS
PHASE LOCKED SYSTEMS
FREQUENCY STANDARDS
STABILITY
description Instead of a hydrogen maser, a carefully selected Crystal oscillator which is phase locked to a Cesium (Cs) frequency standard for time range of more than 100 seconds is adopted to the time and frequency standard of a geodetic VLBI experiment. The domestic VLBI experiment with 55km baseline using the Crystal oscillator at one end was made in Japan and the obtained error of the baseline vector components were 4cm, and that of the baseline length was 3cm. This system may be operated after only 2 hours warm up. These results coincides with those of conventional geodetic Laser ranging and VLBI using a hydrogen maser within the formal error. A VLBI experiment with over 1000km baselines were carried out successfully from October 1988, and over 11000km baseline bctween Japan and Antarctica was carried out succcssfully in January 1990. See also ADA239372. Presented at the Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting (22nd) held in Vienna, VA on 4-6 December 1990. Published in the Proceedings of the Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting (22nd), p131-143, December 1990.
author2 COMMUNICATIONS RESEARCH LAB TOKYO (JAPAN)
format Text
author Kiuchi, Hitoshi
Amagai, Jun
author_facet Kiuchi, Hitoshi
Amagai, Jun
author_sort Kiuchi, Hitoshi
title A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment
title_short A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment
title_full A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment
title_fullStr A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment
title_full_unstemmed A Highly Stable Crystal Oscillator Applied to Geodetic VLBI Experiment
title_sort highly stable crystal oscillator applied to geodetic vlbi experiment
publishDate 1990
url http://www.dtic.mil/docs/citations/ADA519486
http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA519486
genre Antarc*
Antarctica
genre_facet Antarc*
Antarctica
op_source DTIC
op_relation http://www.dtic.mil/docs/citations/ADA519486
op_rights Approved for public release; distribution is unlimited.
_version_ 1766249226496376832