Aquifer Test Report Galena Airport Alaska

In August 1993, the Air Force conducted aquifer tests near the POL saddle Tank Site (ST05) at Galena Airport, Alaska. Aquifer test data was acquired in seven observation during a short-term (9.5 hour) pumping test in conjunction with downhole heat-pulse flowmeter recordings in six wells. Analysis of...

Full description

Bibliographic Details
Other Authors: RADIAN CORP AUSTIN TX
Format: Text
Language:English
Published: 1994
Subjects:
Online Access:http://www.dtic.mil/docs/citations/ADA286059
http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA286059
id ftdtic:ADA286059
record_format openpolar
spelling ftdtic:ADA286059 2023-05-15T18:45:59+02:00 Aquifer Test Report Galena Airport Alaska RADIAN CORP AUSTIN TX 1994-10-31 text/html http://www.dtic.mil/docs/citations/ADA286059 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA286059 en eng http://www.dtic.mil/docs/citations/ADA286059 Approved for public release; distribution is unlimited. DTIC AND NTIS Geology Geochemistry and Mineralogy *AQUIFERS TEST AND EVALUATION VELOCITY THICKNESS AIR FORCE RECOVERY CONDUCTIVITY PARAMETERS MATERIALS HIGH VELOCITY OBSERVATION SITES ALASKA DEPTH REGIONS ESTIMATES REDUCTION ENVIRONMENTAL IMPACT PULSES TRANSITIONS VALUE RIVERS HEAT HYDRAULICS AIRPORTS FLOWMETERS PUMPING TRANSMISSIVITY ADDITION *AQUIFER TESTS Text 1994 ftdtic 2016-02-22T02:00:44Z In August 1993, the Air Force conducted aquifer tests near the POL saddle Tank Site (ST05) at Galena Airport, Alaska. Aquifer test data was acquired in seven observation during a short-term (9.5 hour) pumping test in conjunction with downhole heat-pulse flowmeter recordings in six wells. Analysis of drawdown and recovery data from the pumping test showed the transmissivity ranges from 24,000 to 120,000 ft 2/day with an overall increase with depth consistent with the coarsening nature of the Yukon River aquifer material. The calculated storativity values range from 0.05 to 0.0006, generally decreasing with depth, indicating that shallow unconfined conditions transition to confined conditions at depth. Using an affected aquifer thickness of 100 ft, the hydraulic conductivity ranges from 241 to 1203 ft/day. Average groundwater velocity ranges from 0.31 to 1.56 ft/day. For each 10-ft aquifer zone, the flowmeter velocities were consistently 3.2 to 20 times higher than the calculated velocity from the pumping test. The objectives of the aquifer testing were met-the pumping test provided useful estimates for hydraulic parameters. In addition, the flowmeter, proved to be useful in identifying discrete aquifer zones of high velocity, although velocity estimates did not agree well with those derived from the pumping test. Text Yukon river Alaska Yukon Defense Technical Information Center: DTIC Technical Reports database Yukon
institution Open Polar
collection Defense Technical Information Center: DTIC Technical Reports database
op_collection_id ftdtic
language English
topic Geology
Geochemistry and Mineralogy
*AQUIFERS
TEST AND EVALUATION
VELOCITY
THICKNESS
AIR FORCE
RECOVERY
CONDUCTIVITY
PARAMETERS
MATERIALS
HIGH VELOCITY
OBSERVATION
SITES
ALASKA
DEPTH
REGIONS
ESTIMATES
REDUCTION
ENVIRONMENTAL IMPACT
PULSES
TRANSITIONS
VALUE
RIVERS
HEAT
HYDRAULICS
AIRPORTS
FLOWMETERS
PUMPING
TRANSMISSIVITY
ADDITION
*AQUIFER TESTS
spellingShingle Geology
Geochemistry and Mineralogy
*AQUIFERS
TEST AND EVALUATION
VELOCITY
THICKNESS
AIR FORCE
RECOVERY
CONDUCTIVITY
PARAMETERS
MATERIALS
HIGH VELOCITY
OBSERVATION
SITES
ALASKA
DEPTH
REGIONS
ESTIMATES
REDUCTION
ENVIRONMENTAL IMPACT
PULSES
TRANSITIONS
VALUE
RIVERS
HEAT
HYDRAULICS
AIRPORTS
FLOWMETERS
PUMPING
TRANSMISSIVITY
ADDITION
*AQUIFER TESTS
Aquifer Test Report Galena Airport Alaska
topic_facet Geology
Geochemistry and Mineralogy
*AQUIFERS
TEST AND EVALUATION
VELOCITY
THICKNESS
AIR FORCE
RECOVERY
CONDUCTIVITY
PARAMETERS
MATERIALS
HIGH VELOCITY
OBSERVATION
SITES
ALASKA
DEPTH
REGIONS
ESTIMATES
REDUCTION
ENVIRONMENTAL IMPACT
PULSES
TRANSITIONS
VALUE
RIVERS
HEAT
HYDRAULICS
AIRPORTS
FLOWMETERS
PUMPING
TRANSMISSIVITY
ADDITION
*AQUIFER TESTS
description In August 1993, the Air Force conducted aquifer tests near the POL saddle Tank Site (ST05) at Galena Airport, Alaska. Aquifer test data was acquired in seven observation during a short-term (9.5 hour) pumping test in conjunction with downhole heat-pulse flowmeter recordings in six wells. Analysis of drawdown and recovery data from the pumping test showed the transmissivity ranges from 24,000 to 120,000 ft 2/day with an overall increase with depth consistent with the coarsening nature of the Yukon River aquifer material. The calculated storativity values range from 0.05 to 0.0006, generally decreasing with depth, indicating that shallow unconfined conditions transition to confined conditions at depth. Using an affected aquifer thickness of 100 ft, the hydraulic conductivity ranges from 241 to 1203 ft/day. Average groundwater velocity ranges from 0.31 to 1.56 ft/day. For each 10-ft aquifer zone, the flowmeter velocities were consistently 3.2 to 20 times higher than the calculated velocity from the pumping test. The objectives of the aquifer testing were met-the pumping test provided useful estimates for hydraulic parameters. In addition, the flowmeter, proved to be useful in identifying discrete aquifer zones of high velocity, although velocity estimates did not agree well with those derived from the pumping test.
author2 RADIAN CORP AUSTIN TX
format Text
title Aquifer Test Report Galena Airport Alaska
title_short Aquifer Test Report Galena Airport Alaska
title_full Aquifer Test Report Galena Airport Alaska
title_fullStr Aquifer Test Report Galena Airport Alaska
title_full_unstemmed Aquifer Test Report Galena Airport Alaska
title_sort aquifer test report galena airport alaska
publishDate 1994
url http://www.dtic.mil/docs/citations/ADA286059
http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA286059
geographic Yukon
geographic_facet Yukon
genre Yukon river
Alaska
Yukon
genre_facet Yukon river
Alaska
Yukon
op_source DTIC AND NTIS
op_relation http://www.dtic.mil/docs/citations/ADA286059
op_rights Approved for public release; distribution is unlimited.
_version_ 1766237208833949696