Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter.
The U.S. Army Aviation Center conducted the Operational Test II (OTII) to determine whether the emergency repair shelter for the CH-47 helicopter meets the requirements of the approved material need (MN) during temperate and simulated Arctic conditions. Four shelters were tested from November 1973 t...
Other Authors: | |
---|---|
Format: | Text |
Language: | English |
Published: |
1974
|
Subjects: | |
Online Access: | http://www.dtic.mil/docs/citations/ADA037439 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA037439 |
id |
ftdtic:ADA037439 |
---|---|
record_format |
openpolar |
spelling |
ftdtic:ADA037439 2023-05-15T14:47:53+02:00 Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter. ARMY AVIATION CENTER FORT RUCKER ALA 1974-09-26 text/html http://www.dtic.mil/docs/citations/ADA037439 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA037439 en eng http://www.dtic.mil/docs/citations/ADA037439 APPROVED FOR PUBLIC RELEASE DTIC AND NTIS Helicopters Structural Engineering and Building Technology *SHELTERS *HELICOPTERS TEST AND EVALUATION LOW TEMPERATURE EMERGENCIES MAINTAINABILITY REPAIR TENTS FAILURE(MECHANICS) ARCTIC REGIONS ZIPPERS CH-47 aircraft *H-47 aircraft Text 1974 ftdtic 2016-02-20T12:24:43Z The U.S. Army Aviation Center conducted the Operational Test II (OTII) to determine whether the emergency repair shelter for the CH-47 helicopter meets the requirements of the approved material need (MN) during temperate and simulated Arctic conditions. Four shelters were tested from November 1973 through June 1974 at Fort Rucker, Alabama; Appalachicola, FL and in the McKinley Climatic Laboratory at Eglin Air Force Base, FL. Several zippers on the sidewall of the shelter failed during the test, indicating a lack of durability. It was concluded that the emergency repair shelter will meet the requirements of the approved material need for temperature and Arctic climatic conditions when the durability problem is corrected. (Author) Text Arctic Defense Technical Information Center: DTIC Technical Reports database Alabama Arctic |
institution |
Open Polar |
collection |
Defense Technical Information Center: DTIC Technical Reports database |
op_collection_id |
ftdtic |
language |
English |
topic |
Helicopters Structural Engineering and Building Technology *SHELTERS *HELICOPTERS TEST AND EVALUATION LOW TEMPERATURE EMERGENCIES MAINTAINABILITY REPAIR TENTS FAILURE(MECHANICS) ARCTIC REGIONS ZIPPERS CH-47 aircraft *H-47 aircraft |
spellingShingle |
Helicopters Structural Engineering and Building Technology *SHELTERS *HELICOPTERS TEST AND EVALUATION LOW TEMPERATURE EMERGENCIES MAINTAINABILITY REPAIR TENTS FAILURE(MECHANICS) ARCTIC REGIONS ZIPPERS CH-47 aircraft *H-47 aircraft Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter. |
topic_facet |
Helicopters Structural Engineering and Building Technology *SHELTERS *HELICOPTERS TEST AND EVALUATION LOW TEMPERATURE EMERGENCIES MAINTAINABILITY REPAIR TENTS FAILURE(MECHANICS) ARCTIC REGIONS ZIPPERS CH-47 aircraft *H-47 aircraft |
description |
The U.S. Army Aviation Center conducted the Operational Test II (OTII) to determine whether the emergency repair shelter for the CH-47 helicopter meets the requirements of the approved material need (MN) during temperate and simulated Arctic conditions. Four shelters were tested from November 1973 through June 1974 at Fort Rucker, Alabama; Appalachicola, FL and in the McKinley Climatic Laboratory at Eglin Air Force Base, FL. Several zippers on the sidewall of the shelter failed during the test, indicating a lack of durability. It was concluded that the emergency repair shelter will meet the requirements of the approved material need for temperature and Arctic climatic conditions when the durability problem is corrected. (Author) |
author2 |
ARMY AVIATION CENTER FORT RUCKER ALA |
format |
Text |
title |
Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter. |
title_short |
Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter. |
title_full |
Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter. |
title_fullStr |
Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter. |
title_full_unstemmed |
Operational Test II (OT II) of Emergency Repair Shelter for the CH-47 Helicopter. |
title_sort |
operational test ii (ot ii) of emergency repair shelter for the ch-47 helicopter. |
publishDate |
1974 |
url |
http://www.dtic.mil/docs/citations/ADA037439 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=ADA037439 |
geographic |
Alabama Arctic |
geographic_facet |
Alabama Arctic |
genre |
Arctic |
genre_facet |
Arctic |
op_source |
DTIC AND NTIS |
op_relation |
http://www.dtic.mil/docs/citations/ADA037439 |
op_rights |
APPROVED FOR PUBLIC RELEASE |
_version_ |
1766318981925306368 |