FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.

A number of relatively elementary tests were run with thermocouples, connectors and potentiometers to determine response characteristics under transient and differential temperature conditions. Results are intended to serve as a guide to observers in obtaining accurate temperature determinations. Un...

Full description

Bibliographic Details
Other Authors: ARCTIC CONSTRUCTION AND FROST EFFECTS LAB BOSTON MASS
Format: Text
Language:English
Published: 1956
Subjects:
Ice
Online Access:http://www.dtic.mil/docs/citations/AD0712647
http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=AD0712647
id ftdtic:AD0712647
record_format openpolar
spelling ftdtic:AD0712647 2023-05-15T16:37:31+02:00 FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT. ARCTIC CONSTRUCTION AND FROST EFFECTS LAB BOSTON MASS 1956-12 text/html http://www.dtic.mil/docs/citations/AD0712647 http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=AD0712647 en eng http://www.dtic.mil/docs/citations/AD0712647 APPROVED FOR PUBLIC RELEASE DTIC AND NTIS Snow Ice and Permafrost Test Facilities Equipment and Methods (*TEMPERATURE SENSITIVE ELEMENTS ERRORS) MEASUREMENT THERMOCOUPLES POTENTIOMETERS TEMPERATURE RESPONSE TEST EQUIPMENT TEST METHODS STATISTICAL DATA EVALUATION Text 1956 ftdtic 2016-02-18T23:49:07Z A number of relatively elementary tests were run with thermocouples, connectors and potentiometers to determine response characteristics under transient and differential temperature conditions. Results are intended to serve as a guide to observers in obtaining accurate temperature determinations. Under the conditions of the tests, as much as 10 minutes was required before accurate readings could be obtained, while connectors or potentiometers were adjusting to temperature changes. Other effects of temperature differences were also observed. (Author) Text Ice permafrost Defense Technical Information Center: DTIC Technical Reports database
institution Open Polar
collection Defense Technical Information Center: DTIC Technical Reports database
op_collection_id ftdtic
language English
topic Snow
Ice and Permafrost
Test Facilities
Equipment and Methods
(*TEMPERATURE SENSITIVE ELEMENTS
ERRORS)
MEASUREMENT
THERMOCOUPLES
POTENTIOMETERS
TEMPERATURE
RESPONSE
TEST EQUIPMENT
TEST METHODS
STATISTICAL DATA
EVALUATION
spellingShingle Snow
Ice and Permafrost
Test Facilities
Equipment and Methods
(*TEMPERATURE SENSITIVE ELEMENTS
ERRORS)
MEASUREMENT
THERMOCOUPLES
POTENTIOMETERS
TEMPERATURE
RESPONSE
TEST EQUIPMENT
TEST METHODS
STATISTICAL DATA
EVALUATION
FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.
topic_facet Snow
Ice and Permafrost
Test Facilities
Equipment and Methods
(*TEMPERATURE SENSITIVE ELEMENTS
ERRORS)
MEASUREMENT
THERMOCOUPLES
POTENTIOMETERS
TEMPERATURE
RESPONSE
TEST EQUIPMENT
TEST METHODS
STATISTICAL DATA
EVALUATION
description A number of relatively elementary tests were run with thermocouples, connectors and potentiometers to determine response characteristics under transient and differential temperature conditions. Results are intended to serve as a guide to observers in obtaining accurate temperature determinations. Under the conditions of the tests, as much as 10 minutes was required before accurate readings could be obtained, while connectors or potentiometers were adjusting to temperature changes. Other effects of temperature differences were also observed. (Author)
author2 ARCTIC CONSTRUCTION AND FROST EFFECTS LAB BOSTON MASS
format Text
title FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.
title_short FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.
title_full FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.
title_fullStr FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.
title_full_unstemmed FROST INVESTIGATIONS. FISCAL YEAR 1957. DETERMINATION OF ERRORS IN TEMPERATURE MEASURING EQUIPMENT.
title_sort frost investigations. fiscal year 1957. determination of errors in temperature measuring equipment.
publishDate 1956
url http://www.dtic.mil/docs/citations/AD0712647
http://oai.dtic.mil/oai/oai?&verb=getRecord&metadataPrefix=html&identifier=AD0712647
genre Ice
permafrost
genre_facet Ice
permafrost
op_source DTIC AND NTIS
op_relation http://www.dtic.mil/docs/citations/AD0712647
op_rights APPROVED FOR PUBLIC RELEASE
_version_ 1766027803615035392