Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf

Finite Element Analysis (FEA) is a powerful tool gaining use in studies of biological form and function. This method is particularly conducive to studies of extinct and fossilized organisms, as models can be assigned properties that approximate living tissues. In disciplines where model validation i...

Full description

Bibliographic Details
Main Authors: Tseng, Zhijie Jack, McNitt-Gray, Jill L., Flashner, Henryk, Wang, Xiaoming, Enciso, Reyes
Format: Article in Journal/Newspaper
Language:unknown
Published: 2011
Subjects:
Online Access:http://hdl.handle.net/10255/dryad.8961
https://doi.org/10.5061/dryad.8961
id ftdryad:oai:v1.datadryad.org:10255/dryad.8961
record_format openpolar
spelling ftdryad:oai:v1.datadryad.org:10255/dryad.8961 2023-05-15T15:51:08+02:00 Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf Tseng, Zhijie Jack McNitt-Gray, Jill L. Flashner, Henryk Wang, Xiaoming Enciso, Reyes 2011-03-29T20:37:04Z http://hdl.handle.net/10255/dryad.8961 https://doi.org/10.5061/dryad.8961 unknown doi:10.5061/dryad.8961/1 doi:10.1371/journal.pone.0019171 PMID:21559475 doi:10.5061/dryad.8961 Tseng ZJ, McNitt-Gray JL, Flashner H, Wang X, Enciso R (2011) Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf. PLoS ONE 6(4): e19171. http://hdl.handle.net/10255/dryad.8961 sensitivity analysis finite element analysis biomechanics mandible functional morphology vertebrate paleontology bite force mastication Article 2011 ftdryad https://doi.org/10.5061/dryad.8961 https://doi.org/10.5061/dryad.8961/1 https://doi.org/10.1371/journal.pone.0019171 2020-01-01T14:21:03Z Finite Element Analysis (FEA) is a powerful tool gaining use in studies of biological form and function. This method is particularly conducive to studies of extinct and fossilized organisms, as models can be assigned properties that approximate living tissues. In disciplines where model validation is difficult or impossible, the choice of model parameters and their effects on the results become increasingly important, especially in comparing outputs to infer function. To evaluate the extent to which performance measures are affected by initial model input, we tested the sensitivity of bite force, strain energy, and stress to changes in seven parameters that are required in testing craniodental function with FEA. Simulations were performed on FE models of a Gray Wolf (Canis lupus) mandible. Results showed that unilateral bite force outputs are least affected by the relative ratios of the balancing and working muscles, but only ratios above 0.5 provided balancing-working side joint reaction force relationships that are consistent with experimental data. The constraints modeled at the bite point had the greatest effect on bite force output, but the most appropriate constraint may depend on the study question. Strain energy is least affected by variation in bite point constraint, but larger variations in strain energy values are observed in models with different number of tetrahedral elements, masticatory muscle ratios and muscle subgroups present, and number of material properties. These findings indicate that performance measures are differentially affected by variation in initial model parameters. In the absence of validated input values, FE models can nevertheless provide robust comparisons if these parameters are standardized within a given study to minimize variation that arise during the model-building process. Sensitivity tests incorporated into the study design not only aid in the interpretation of simulation results, but can also provide additional insights on form and function. Article in Journal/Newspaper Canis lupus gray wolf Dryad Digital Repository (Duke University)
institution Open Polar
collection Dryad Digital Repository (Duke University)
op_collection_id ftdryad
language unknown
topic sensitivity analysis
finite element analysis
biomechanics
mandible
functional morphology
vertebrate paleontology
bite force
mastication
spellingShingle sensitivity analysis
finite element analysis
biomechanics
mandible
functional morphology
vertebrate paleontology
bite force
mastication
Tseng, Zhijie Jack
McNitt-Gray, Jill L.
Flashner, Henryk
Wang, Xiaoming
Enciso, Reyes
Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf
topic_facet sensitivity analysis
finite element analysis
biomechanics
mandible
functional morphology
vertebrate paleontology
bite force
mastication
description Finite Element Analysis (FEA) is a powerful tool gaining use in studies of biological form and function. This method is particularly conducive to studies of extinct and fossilized organisms, as models can be assigned properties that approximate living tissues. In disciplines where model validation is difficult or impossible, the choice of model parameters and their effects on the results become increasingly important, especially in comparing outputs to infer function. To evaluate the extent to which performance measures are affected by initial model input, we tested the sensitivity of bite force, strain energy, and stress to changes in seven parameters that are required in testing craniodental function with FEA. Simulations were performed on FE models of a Gray Wolf (Canis lupus) mandible. Results showed that unilateral bite force outputs are least affected by the relative ratios of the balancing and working muscles, but only ratios above 0.5 provided balancing-working side joint reaction force relationships that are consistent with experimental data. The constraints modeled at the bite point had the greatest effect on bite force output, but the most appropriate constraint may depend on the study question. Strain energy is least affected by variation in bite point constraint, but larger variations in strain energy values are observed in models with different number of tetrahedral elements, masticatory muscle ratios and muscle subgroups present, and number of material properties. These findings indicate that performance measures are differentially affected by variation in initial model parameters. In the absence of validated input values, FE models can nevertheless provide robust comparisons if these parameters are standardized within a given study to minimize variation that arise during the model-building process. Sensitivity tests incorporated into the study design not only aid in the interpretation of simulation results, but can also provide additional insights on form and function.
format Article in Journal/Newspaper
author Tseng, Zhijie Jack
McNitt-Gray, Jill L.
Flashner, Henryk
Wang, Xiaoming
Enciso, Reyes
author_facet Tseng, Zhijie Jack
McNitt-Gray, Jill L.
Flashner, Henryk
Wang, Xiaoming
Enciso, Reyes
author_sort Tseng, Zhijie Jack
title Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf
title_short Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf
title_full Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf
title_fullStr Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf
title_full_unstemmed Data from: Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf
title_sort data from: model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the gray wolf
publishDate 2011
url http://hdl.handle.net/10255/dryad.8961
https://doi.org/10.5061/dryad.8961
genre Canis lupus
gray wolf
genre_facet Canis lupus
gray wolf
op_relation doi:10.5061/dryad.8961/1
doi:10.1371/journal.pone.0019171
PMID:21559475
doi:10.5061/dryad.8961
Tseng ZJ, McNitt-Gray JL, Flashner H, Wang X, Enciso R (2011) Model sensitivity and use of the comparative finite element method in mammalian jaw mechanics: mandible performance in the Gray Wolf. PLoS ONE 6(4): e19171.
http://hdl.handle.net/10255/dryad.8961
op_doi https://doi.org/10.5061/dryad.8961
https://doi.org/10.5061/dryad.8961/1
https://doi.org/10.1371/journal.pone.0019171
_version_ 1766386195475988480