Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water

INTRODUCTION: The production of anti-Cryptosporidium polyclonal antibodies and its use in direct immunofluorescence assays to determine the presence of Cryptosporidium in water are described in the present work. METHODS: Two rabbits were immunized with soluble and particulate antigens from purified...

Full description

Bibliographic Details
Published in:Revista da Sociedade Brasileira de Medicina Tropical
Main Authors: Silvia Cristina Osaki, Adriana Oliveira Costa, Ludmilla Della Coletta Troiano, Ernesto Renato Kruger, Juliana Tracz Pereira, Nelson Luis Mello Fernandes, Márcia Benedita de Oliveira Silva, Vanete Thomaz Soccol
Format: Article in Journal/Newspaper
Language:English
Published: Sociedade Brasileira de Medicina Tropical (SBMT) 2011
Subjects:
Online Access:https://doi.org/10.1590/S0037-86822011000500011
https://doaj.org/article/9ac2a2077e6b4b5b845a5c8873617e8a
id ftdoajarticles:oai:doaj.org/article:9ac2a2077e6b4b5b845a5c8873617e8a
record_format openpolar
spelling ftdoajarticles:oai:doaj.org/article:9ac2a2077e6b4b5b845a5c8873617e8a 2023-05-15T15:05:09+02:00 Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water Silvia Cristina Osaki Adriana Oliveira Costa Ludmilla Della Coletta Troiano Ernesto Renato Kruger Juliana Tracz Pereira Nelson Luis Mello Fernandes Márcia Benedita de Oliveira Silva Vanete Thomaz Soccol 2011-10-01T00:00:00Z https://doi.org/10.1590/S0037-86822011000500011 https://doaj.org/article/9ac2a2077e6b4b5b845a5c8873617e8a EN eng Sociedade Brasileira de Medicina Tropical (SBMT) http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0037-86822011000500011&lng=en&tlng=en https://doaj.org/toc/1678-9849 1678-9849 doi:10.1590/S0037-86822011000500011 https://doaj.org/article/9ac2a2077e6b4b5b845a5c8873617e8a Revista da Sociedade Brasileira de Medicina Tropical, Vol 44, Iss 5, Pp 587-590 (2011) Anticorpos policlonais Imunofluorescência direta Oocistos Água Arctic medicine. Tropical medicine RC955-962 article 2011 ftdoajarticles https://doi.org/10.1590/S0037-86822011000500011 2022-12-30T21:37:26Z INTRODUCTION: The production of anti-Cryptosporidium polyclonal antibodies and its use in direct immunofluorescence assays to determine the presence of Cryptosporidium in water are described in the present work. METHODS: Two rabbits were immunized with soluble and particulate antigens from purified Cryptosporidium oocysts. The sera produced were prepared for immunoglobulin G extraction, which were then purified and conjugated with fluorescein isothiocyanate (FITC). Slides containing known amounts of oocysts were prepared to determine the sensitivity of the technique. To test the specificity, slides containing Giardia duodenalis cysts were prepared. RESULTS: The conjugate was successfully used in water samples experimentally contaminated with Cryptosporidium oocysts, and it was possible to detect up to five oocysts/spot, corresponding to contamination of 250 oocysts/mL. CONCLUSIONS: The three immunizations performed in the rabbits were enough to produce antibodies against Cryptosporidium, the standard direct immunofluorescence assay permitted the detection of five oocysts in 20% of the samples, and no cross-reaction with Giardia duodenalis cysts occurred. Article in Journal/Newspaper Arctic Directory of Open Access Journals: DOAJ Articles Arctic Revista da Sociedade Brasileira de Medicina Tropical 44 5 587 590
institution Open Polar
collection Directory of Open Access Journals: DOAJ Articles
op_collection_id ftdoajarticles
language English
topic Anticorpos policlonais
Imunofluorescência direta
Oocistos
Água
Arctic medicine. Tropical medicine
RC955-962
spellingShingle Anticorpos policlonais
Imunofluorescência direta
Oocistos
Água
Arctic medicine. Tropical medicine
RC955-962
Silvia Cristina Osaki
Adriana Oliveira Costa
Ludmilla Della Coletta Troiano
Ernesto Renato Kruger
Juliana Tracz Pereira
Nelson Luis Mello Fernandes
Márcia Benedita de Oliveira Silva
Vanete Thomaz Soccol
Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water
topic_facet Anticorpos policlonais
Imunofluorescência direta
Oocistos
Água
Arctic medicine. Tropical medicine
RC955-962
description INTRODUCTION: The production of anti-Cryptosporidium polyclonal antibodies and its use in direct immunofluorescence assays to determine the presence of Cryptosporidium in water are described in the present work. METHODS: Two rabbits were immunized with soluble and particulate antigens from purified Cryptosporidium oocysts. The sera produced were prepared for immunoglobulin G extraction, which were then purified and conjugated with fluorescein isothiocyanate (FITC). Slides containing known amounts of oocysts were prepared to determine the sensitivity of the technique. To test the specificity, slides containing Giardia duodenalis cysts were prepared. RESULTS: The conjugate was successfully used in water samples experimentally contaminated with Cryptosporidium oocysts, and it was possible to detect up to five oocysts/spot, corresponding to contamination of 250 oocysts/mL. CONCLUSIONS: The three immunizations performed in the rabbits were enough to produce antibodies against Cryptosporidium, the standard direct immunofluorescence assay permitted the detection of five oocysts in 20% of the samples, and no cross-reaction with Giardia duodenalis cysts occurred.
format Article in Journal/Newspaper
author Silvia Cristina Osaki
Adriana Oliveira Costa
Ludmilla Della Coletta Troiano
Ernesto Renato Kruger
Juliana Tracz Pereira
Nelson Luis Mello Fernandes
Márcia Benedita de Oliveira Silva
Vanete Thomaz Soccol
author_facet Silvia Cristina Osaki
Adriana Oliveira Costa
Ludmilla Della Coletta Troiano
Ernesto Renato Kruger
Juliana Tracz Pereira
Nelson Luis Mello Fernandes
Márcia Benedita de Oliveira Silva
Vanete Thomaz Soccol
author_sort Silvia Cristina Osaki
title Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water
title_short Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water
title_full Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water
title_fullStr Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water
title_full_unstemmed Production of anti-Cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water
title_sort production of anti-cryptosporidium polyclonal antibodies and standardization of direct immunofluorescence for detecting oocysts in water
publisher Sociedade Brasileira de Medicina Tropical (SBMT)
publishDate 2011
url https://doi.org/10.1590/S0037-86822011000500011
https://doaj.org/article/9ac2a2077e6b4b5b845a5c8873617e8a
geographic Arctic
geographic_facet Arctic
genre Arctic
genre_facet Arctic
op_source Revista da Sociedade Brasileira de Medicina Tropical, Vol 44, Iss 5, Pp 587-590 (2011)
op_relation http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0037-86822011000500011&lng=en&tlng=en
https://doaj.org/toc/1678-9849
1678-9849
doi:10.1590/S0037-86822011000500011
https://doaj.org/article/9ac2a2077e6b4b5b845a5c8873617e8a
op_doi https://doi.org/10.1590/S0037-86822011000500011
container_title Revista da Sociedade Brasileira de Medicina Tropical
container_volume 44
container_issue 5
container_start_page 587
op_container_end_page 590
_version_ 1766336895614189568