Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station

A structural gasket at the observation hut in Syowa Station has been in use for 35 years. We studied the hardness of the original structural gasket during the 43rd Japanese Antarctic Research Expedition. We tested that of the new article, and the results are assumed to be an initial value. The struc...

Full description

Bibliographic Details
Main Authors: Hiroki Takahashi, Toshio Hannuki, Masaru Ayukawa, Yoshika Takechi, Tohru Ohtsuka
Format: Article in Journal/Newspaper
Language:English
Japanese
Published: National Institute of Polar Research 2014
Subjects:
Online Access:https://doi.org/10.15094/00009724
https://doaj.org/article/8d6c641787f6413890a98a8ffcc943ad
id ftdoajarticles:oai:doaj.org/article:8d6c641787f6413890a98a8ffcc943ad
record_format openpolar
spelling ftdoajarticles:oai:doaj.org/article:8d6c641787f6413890a98a8ffcc943ad 2023-05-15T13:47:23+02:00 Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station Hiroki Takahashi Toshio Hannuki Masaru Ayukawa Yoshika Takechi Tohru Ohtsuka 2014-03-01T00:00:00Z https://doi.org/10.15094/00009724 https://doaj.org/article/8d6c641787f6413890a98a8ffcc943ad EN JA eng jpn National Institute of Polar Research http://doi.org/10.15094/00009724 https://doaj.org/toc/0085-7289 https://doaj.org/toc/2432-079X doi:10.15094/00009724 0085-7289 2432-079X https://doaj.org/article/8d6c641787f6413890a98a8ffcc943ad Antarctic Record, Vol 58, Iss 1, Pp 42-51 (2014) Geography (General) G1-922 article 2014 ftdoajarticles https://doi.org/10.15094/00009724 2022-12-31T03:09:09Z A structural gasket at the observation hut in Syowa Station has been in use for 35 years. We studied the hardness of the original structural gasket during the 43rd Japanese Antarctic Research Expedition. We tested that of the new article, and the results are assumed to be an initial value. The structural gasket at the northwest section of the station deteriorated to a greater extent than did the structural gasket at the southeast section, because of the former's exposure to ultraviolet radiation. The exterior and interior components of the northwest structural gasket show similar degrees of degradation. This structural gasket has hardened by 10 % relative to the new structural gasket. The 35-year-old structural gasket contains no large cracks, indicating its suitability for continual use. Article in Journal/Newspaper Antarc* Antarctic Directory of Open Access Journals: DOAJ Articles Antarctic Syowa Station
institution Open Polar
collection Directory of Open Access Journals: DOAJ Articles
op_collection_id ftdoajarticles
language English
Japanese
topic Geography (General)
G1-922
spellingShingle Geography (General)
G1-922
Hiroki Takahashi
Toshio Hannuki
Masaru Ayukawa
Yoshika Takechi
Tohru Ohtsuka
Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station
topic_facet Geography (General)
G1-922
description A structural gasket at the observation hut in Syowa Station has been in use for 35 years. We studied the hardness of the original structural gasket during the 43rd Japanese Antarctic Research Expedition. We tested that of the new article, and the results are assumed to be an initial value. The structural gasket at the northwest section of the station deteriorated to a greater extent than did the structural gasket at the southeast section, because of the former's exposure to ultraviolet radiation. The exterior and interior components of the northwest structural gasket show similar degrees of degradation. This structural gasket has hardened by 10 % relative to the new structural gasket. The 35-year-old structural gasket contains no large cracks, indicating its suitability for continual use.
format Article in Journal/Newspaper
author Hiroki Takahashi
Toshio Hannuki
Masaru Ayukawa
Yoshika Takechi
Tohru Ohtsuka
author_facet Hiroki Takahashi
Toshio Hannuki
Masaru Ayukawa
Yoshika Takechi
Tohru Ohtsuka
author_sort Hiroki Takahashi
title Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station
title_short Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station
title_full Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station
title_fullStr Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station
title_full_unstemmed Study on hardness of the 35-year-old structural gasket used at the observation hut in Syowa Station
title_sort study on hardness of the 35-year-old structural gasket used at the observation hut in syowa station
publisher National Institute of Polar Research
publishDate 2014
url https://doi.org/10.15094/00009724
https://doaj.org/article/8d6c641787f6413890a98a8ffcc943ad
geographic Antarctic
Syowa Station
geographic_facet Antarctic
Syowa Station
genre Antarc*
Antarctic
genre_facet Antarc*
Antarctic
op_source Antarctic Record, Vol 58, Iss 1, Pp 42-51 (2014)
op_relation http://doi.org/10.15094/00009724
https://doaj.org/toc/0085-7289
https://doaj.org/toc/2432-079X
doi:10.15094/00009724
0085-7289
2432-079X
https://doaj.org/article/8d6c641787f6413890a98a8ffcc943ad
op_doi https://doi.org/10.15094/00009724
_version_ 1766247063078567936